514 research outputs found

    The N-methyl-d-aspartate receptor antagonist CPP alters synapse and spine structure and impairs long-term potentiation and long-term depression induced morphological plasticity in dentate gyrus of the awake rat

    Get PDF
    Long-term morphological synaptic changes associated with homosynaptic long-term potentiation (LTP) and heterosynaptic long-term depression (LTD) in vivo, in awake adult rats were analyzed using three-dimensional (3-D) reconstructions of electron microscope images of ultrathin serial sections from the molecular layer of the dentate gyrus. For the first time in morphological studies, the specificity of the effects of LTP and LTD on both spine and synapse ultrastructure was determined using an N-methyl-d-aspartate (NMDA) receptor antagonist CPP (3-[(R)-2-carboxypiperazin-4-yl]-propyl-1-phosphonic acid). There were no differences in synaptic density 24 h after LTP or LTD induction, and CPP alone had no effect on synaptic density. LTP increased significantly the proportion of mushroom spines, whereas LTD increased the proportion of thin spines, and both LTP and LTD decreased stubby spine number. Both LTP and LTD increased significantly spine head evaginations (spinules) into synaptic boutons and CPP blocked these changes. Synaptic boutons were smaller after LTD, indicating a pre-synaptic effect. Interestingly, CPP alone decreased bouton and mushroom spine volumes, as well as post-synaptic density (PSD) volume of mushroom spines.These data show similarities, but also some clear differences, between the effects of LTP and LTD on spine and synaptic morphology. Although CPP blocks both LTP and LTD, and impairs most morphological changes in spines and synapses, CPP alone was shown to exert effects on aspects of spine and synaptic structure

    Prospects for measuring the gravitational free-fall of antihydrogen with emulsion detectors

    Get PDF
    The main goal of the AEgIS experiment at CERN is to test the weak equivalence principle for antimatter. AEgIS will measure the free-fall of an antihydrogen beam traversing a moir\'e deflectometer. The goal is to determine the gravitational acceleration g for antihydrogen with an initial relative accuracy of 1% by using an emulsion detector combined with a silicon micro-strip detector to measure the time of flight. Nuclear emulsions can measure the annihilation vertex of antihydrogen atoms with a precision of about 1 - 2 microns r.m.s. We present here results for emulsion detectors operated in vacuum using low energy antiprotons from the CERN antiproton decelerator. We compare with Monte Carlo simulations, and discuss the impact on the AEgIS project.Comment: 20 pages, 16 figures, 3 table

    Extensive Variation in Chromatin States Across Humans

    Get PDF
    The majority of disease-associated variants lie outside protein-coding regions, suggesting a link between variation in regulatory regions and disease predisposition. We studied differences in chromatin states using five histone modifications, cohesin, and CTCF in lymphoblastoid lines from 19 individuals of diverse ancestry. We found extensive signal variation in regulatory regions, which often switch between active and repressed states across individuals. Enhancer activity is particularly diverse among individuals, whereas gene expression remains relatively stable. Chromatin variability shows genetic inheritance in trios, correlates with genetic variation and population divergence, and is associated with disruptions of transcription factor binding motifs. Overall, our results provide insights into chromatin variation among humans

    Three-dimensional reconstruction of synapses and dendritic spines in the rat and ground squirrel hippocampus: New structural-functional paradigms for synaptic function

    Get PDF
    Published data are reviewed along with our own data on synaptic plasticity and rearrangements of synaptic organelles in the central nervous system. Contemporary laser scanning and confocal microscopy techniques are discussed, along with the use of serial ultrathin sections for in vivo and in vitro studies of dendritic spines, including those addressing relationships between morphological changes and the efficiency of synaptic transmission, especially in conditions of the long-term potentiation model. Different categories of dendritic spines and postsynaptic densities are analyzed, as are the roles of filopodia in originating spines. The role of serial ultrathin sections for unbiased quantitative stereological analysis and three-dimensional reconstruction is assessed. The authors data on the formation of more than two synapses on single mushroom spines on neurons in hippocampal field CA1 are discussed. Analysis of these data provides evidence for new paradigms in both the organization and functioning of synapses

    Enumeration of CD4+ T-Cells Using a Portable Microchip Count Platform in Tanzanian HIV-Infected Patients

    Get PDF
    Background CD4+ T-lymphocyte count (CD4 count) is a standard method used to monitor HIV-infected patients during anti-retroviral therapy (ART). The World Health Organization (WHO) has pointed out or recommended that a handheld, point-of-care, reliable, and affordable CD4 count platform is urgently needed in resource-scarce settings. Methods HIV-infected patient blood samples were tested at the point-of-care using a portable and label-free microchip CD4 count platform that we have developed. A total of 130 HIV-infected patient samples were collected that included 16 de-identified left over blood samples from Brigham and Women's Hospital (BWH), and 114 left over samples from Muhimbili University of Health and Allied Sciences (MUHAS) enrolled in the HIV and AIDS care and treatment centers in the City of Dar es Salaam, Tanzania. The two data groups from BWH and MUHAS were analyzed and compared to the commonly accepted CD4 count reference method (FACSCalibur system). Results The portable, battery operated and microscope-free microchip platform developed in our laboratory (BWH) showed significant correlation in CD4 counts compared with FACSCalibur system both at BWH (r = 0.94, p<0.01) and MUHAS (r = 0.49, p<0.01), which was supported by the Bland-Altman methods comparison analysis. The device rapidly produced CD4 count within 10 minutes using an in-house developed automated cell counting program. Conclusions We obtained CD4 counts of HIV-infected patients using a portable platform which is an inexpensive (<$1 material cost) and disposable microchip that uses whole blood sample (<10 ”l) without any pre-processing. The system operates without the need for antibody-based fluorescent labeling and expensive fluorescent illumination and microscope setup. This portable CD4 count platform displays agreement with the FACSCalibur results and has the potential to expand access to HIV and AIDS monitoring using fingerprick volume of whole blood and helping people who suffer from HIV and AIDS in resource-limited settings.Wallace H. Coulter Foundation (Young Investigation Award in Bioengineering Award)National Institutes of Health (U.S.) (NIH R01AI081534)National Institutes of Health (U.S.) (NIH R21AI087107)National Institutes of Health (U.S.) (NIH grant RR016482)National Institutes of Health (U.S.) (grant AI060354)National Institutes of Health (U.S.) (NIH Fogarty Fellowship

    Multiplicity dependence of jet-like two-particle correlations in p-Pb collisions at sNN\sqrt{s_{NN}} = 5.02 TeV

    Full text link
    Two-particle angular correlations between unidentified charged trigger and associated particles are measured by the ALICE detector in p-Pb collisions at a nucleon-nucleon centre-of-mass energy of 5.02 TeV. The transverse-momentum range 0.7 <pT,assoc<pT,trig< < p_{\rm{T}, assoc} < p_{\rm{T}, trig} < 5.0 GeV/cc is examined, to include correlations induced by jets originating from low momen\-tum-transfer scatterings (minijets). The correlations expressed as associated yield per trigger particle are obtained in the pseudorapidity range ∣η∣<0.9|\eta|<0.9. The near-side long-range pseudorapidity correlations observed in high-multiplicity p-Pb collisions are subtracted from both near-side short-range and away-side correlations in order to remove the non-jet-like components. The yields in the jet-like peaks are found to be invariant with event multiplicity with the exception of events with low multiplicity. This invariance is consistent with the particles being produced via the incoherent fragmentation of multiple parton--parton scatterings, while the yield related to the previously observed ridge structures is not jet-related. The number of uncorrelated sources of particle production is found to increase linearly with multiplicity, suggesting no saturation of the number of multi-parton interactions even in the highest multiplicity p-Pb collisions. Further, the number scales in the intermediate multiplicity region with the number of binary nucleon-nucleon collisions estimated with a Glauber Monte-Carlo simulation.Comment: 23 pages, 6 captioned figures, 1 table, authors from page 17, published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/161

    Multi-particle azimuthal correlations in p-Pb and Pb-Pb collisions at the CERN Large Hadron Collider

    Full text link
    Measurements of multi-particle azimuthal correlations (cumulants) for charged particles in p-Pb and Pb-Pb collisions are presented. They help address the question of whether there is evidence for global, flow-like, azimuthal correlations in the p-Pb system. Comparisons are made to measurements from the larger Pb-Pb system, where such evidence is established. In particular, the second harmonic two-particle cumulants are found to decrease with multiplicity, characteristic of a dominance of few-particle correlations in p-Pb collisions. However, when a âˆŁÎ”Î·âˆŁ|\Delta \eta| gap is placed to suppress such correlations, the two-particle cumulants begin to rise at high-multiplicity, indicating the presence of global azimuthal correlations. The Pb-Pb values are higher than the p-Pb values at similar multiplicities. In both systems, the second harmonic four-particle cumulants exhibit a transition from positive to negative values when the multiplicity increases. The negative values allow for a measurement of v2{4}v_{2}\{4\} to be made, which is found to be higher in Pb-Pb collisions at similar multiplicities. The second harmonic six-particle cumulants are also found to be higher in Pb-Pb collisions. In Pb-Pb collisions, we generally find v2{4}≃v2{6}≠0v_{2}\{4\} \simeq v_{2}\{6\}\neq 0 which is indicative of a Bessel-Gaussian function for the v2v_{2} distribution. For very high-multiplicity Pb-Pb collisions, we observe that the four- and six-particle cumulants become consistent with 0. Finally, third harmonic two-particle cumulants in p-Pb and Pb-Pb are measured. These are found to be similar for overlapping multiplicities, when a âˆŁÎ”Î·âˆŁ>1.4|\Delta\eta| > 1.4 gap is placed.Comment: 25 pages, 11 captioned figures, 3 tables, authors from page 20, published version, figures at http://aliceinfo.cern.ch/ArtSubmission/node/87

    A Moiré Deflectometer for Antimatter

    Get PDF
    The precise measurement of forces is one way to obtain deep insight into the fundamental interactions present in nature. In the context of neutral antimatter, the gravitational interaction is of high interest, potentially revealing new forces that violate the weak equivalence principle. Here we report on a successful extension of a tool from atom optics - the moirĂš deflectometer - for a measurement of the acceleration of slow antiprotons. The setup consists of two identical transmission gratings and a spatially resolving emulsion detector for antiproton annihilations. Absolute referencing of the observed antimatter pattern with a photon pattern experiencing no deflection allows the direct inference of forces present. The concept is also straightforwardly applicable to antihydrogen measurements as pursued by the AEgIS collaboration. The combination of these very different techniques from high energy and atomic physics opens a very promising route to the direct detection of the gravitational acceleration of neutral antimatter

    AEgIS Experiment: Measuring the Acceleration g of the Earth's Gravitational Field on Antihydrogen Beam

    Get PDF
    The AEgIS experiment [1] aims at directly measuring the gravitational acceleration g on a beam of cold antihydrogen (H) to a precision of 1%, performing the first test with antimatter of the (WEP) Weak Equivalence Principle. The experimental apparatus is sited at the Antiproton Decelerator (AD) at CERN, Geneva, Switzerland. After production by mixing of antiprotons with Rydberg state positronium atoms (Ps), the atoms will be driven to fly horizontally with a velocity of a few 100 ms−1 for a path length of about 1 meter. The small deflection, few tens of ÎŒm, will be measured using two material gratings (of period ∌ 80 ÎŒm) coupled to a position-sensitive detector working as a moirĂ© deflectometer similarly to what has been done with matter atoms [2]. The shadow pattern produced by the beam will then be detected by reconstructing the annihilation points with a spatial resolution (∌ 2 ÎŒm) of each antiatom at the end of the flight path by the sensitive-position detector. During 2012 the experimental apparatus has been commissioned with antiprotons and positrons. Since the AD will not be running during 2013,during the refurbishment of the CERN accelerators, the experiment is currently working with positrons, electrons and protons, in order to prepare the way for the antihydrogen production in late 2014
    • 

    corecore