2,155 research outputs found

    Mesoscopic structural organization in fluorinated pyrrolidinium based room temperature ionic liquids

    Get PDF
    In this contribution the microscopic and mesoscopic structural organization in a series of fluorinated room temperature ionic liquids, based on N-methyl-N-alkylpyrrolidinium cations and on bis(perfluoroalkylsulfonyl)imide anions, is investigated, using a synergy of experimental (X-ray and neutron scattering) and computational (Molecular Dynamics) techniques. The proposed ionic liquids are of high interest as electrolyte media for lithium battery applications. Together with information on their good ion transport properties in conjunction with low viscosity, we also describe the existence of nm-scale spatial organization induced by the segregation of fluorous moieties into domains. This study shows the strong complementarity between X-ray/neutron scattering in detecting the complex segregated morphology in these systems at mesoscopic spatial scales and MD simulations in successfully delivering a robust description of the segregated morphology at atomistic level

    Navigation Facility for High Accuracy Offline Trajectory and Attitude Estimation in Airborne Applications

    Get PDF
    The paper focuses on a navigation facility, relying on commercial-off-the-shelf (COTS) technology, developed to generate high-accuracy attitude and trajectory measurements in postprocessing. Target performance is cm-level positioning with tenth of degree attitude accuracy. The facility is based on the concept of GPS-aided inertial navigation but comprises carrier-phase differential GPS (CDGPS) processing and attitude estimation based on multiantenna GPS configurations. Expected applications of the system include: (a) performance assessment of integrated navigation systems, developed for general aviation aircraft and medium size unmanned aircraft systems (UAS); (b) generation of reference measurements to evaluate the flight performance of airborne sensors (e.g., radar or laser); and (c) generation of reference trajectory and attitude for improving imaging quality of airborne remote sensing data. The paper describes system architecture, selected algorithms for data processing and integration, and theoretical performance evaluation. Experimental results are also presented confirming the effectiveness of the implemented approach

    Diffusion tensor imaging and magnetic resonance spectroscopy assessment of cancellous bone quality in femoral neck of healthy, osteopenic and osteoporotic subjects at 3T: Preliminary experience.

    Get PDF
    We assessed the potential of diffusion tensor imaging (DTI) in combination with proton magnetic resonance spectroscopy ((1)H-MRS), in cancellous bone quality evaluation of the femoral neck in postmenopausal women. INTRODUCTION: DTI allows for non-invasive microarchitectural characterization of heterogeneous tissue. In this work we hypothesized that DTI parameters mean diffusivity (MD) and fractional anisotropy (FA) of bone marrow water, can provide information about microstructural changes that occur with the development of osteoporosis disease. Because osteoporosis is associated with increased bone marrow fat content, which in principal can alter DTI parameters, the goal of this study was to examine the potential of MD and FA, in combination with bone marrow fat fraction (FF), to discriminate between healthy, osteopenic and osteoporotic subjects, classified according to DXA criteria. MATERIALS AND METHODS: Forty postmenopausal women (mean age, 68.7years; range 52-81years), underwent a Dual-energy X-ray absorptiometry (DXA) examination in femoral neck, to be classified as healthy (n=12), osteopenic (n=14) and osteoporotic (n=14) subjects. (1)H-MRS and DTI (with b value=2500s/mm(2)) of femoral neck were obtained in each subject at 3T. The study protocol was approved by local Ethics Committee. MD, FA, FF and MD/FF, FA/FF were obtained and compared among the three bone-density groups. One-way ANOVA with multiple comparisons Bonferroni test and Pearson correlation analysis were applied. Receiver operating characteristic (ROC) curve analysis was also performed. RESULTS: Reproducibility of DTI measures was satisfactory. CV was approximately 2%-3% for MD and 4%-5% for FA measurements. Moreover, no significant difference was found in both MD and FA measurements between two separate sessions (median 34days apart) comprised of six healthy volunteers. FF was able to discriminate between healthy and osteoporotic subjects only. Conversely MD and FA were able to discriminate healthy from osteopenic and healthy from osteoporotic subjects, but they were not able to discriminate between osteopenic and osteoporotic patients. A significant correlation between MD and FF was observed in healthy group only. A moderate correlation was found between MD and T-score when all groups together are considered. No significant correlation was found between MD and T-score within groups. A significant positive correlation between FA and FF was found in both osteopenic and osteoporotic groups. Vice-versa no correlation between FA and FF was observed in healthy group. A high significant positive correlation was found between FA and T-score in all groups together, in healthy and in osteoporotic groups. MD/FF and FA/FF are characterized by a higher sensitivity and specificity compared to MD and FA in the discrimination between healthy, and osteoporotic subjects. MD/FF vs FA/FF graph extracted from femoral neck, identify all healthy individuals according to DXA results. CONCLUSION: DTI-(1)H-MRS protocol performed in femoral neck seems to be highly sensitive and specific in identifying healthy subjects. A MR exam is more expensive when compared to a DXA investigation. However, even though DXA BMD evaluation has been the accepted standard for osteoporosis diagnosis, DXA result has a low predictive value on patients' risk for future fractures. Thus, new approaches for examining patients at risk for developing osteoporosis would be desirable. Preliminary results showed here suggest that future studies on a larger population based on DTI assessment in the femoral neck, in combination with (1)H-MRS investigations, might allow screening of high-risk populations and the establishment of cut-off values of normality, with potential application of the method to single subjects

    Effects of steroids and tocilizumab on the immune response profile of patients with covid-19-associated ards requiring or not veno-venous extracorporeal membrane oxygenation

    Get PDF
    Veno-venous extracorporeal membrane oxygenation (VV-ECMO) is a life-saving rescue therapy in patients with Acute Respiratory Distress Syndrome (ARDS). ECMO has been associated with development of lymphocytopenia that is also common in COVID-19. Hyperinflammation may complicate SARS-CoV-2 pneumonia, prompting therapy with steroids and immunomodulatory drugs. We aimed to evaluate the association of therapies such as steroids and Tocilizumab with trajectories of the total leukocytes, lymphocyte subpopulation count, and inflammatory and fibrinolysis markers in COVID-19-related ARDS, requiring or not VV-ECMO support. The association of the trajectories of the leukocytes, lymphocyte subpopulation count, and inflammatory and fibrinolysis markers with treatment with steroids (Steroids), Tocilizumab (Tocilizumab), both drugs (Steroids + Tocilizumab), and absence of treatment (No Treatment) were analyzed using mixed effects regression models, where ECMO was considered as a potential effect modifier. One hundred and thirty-nine leukocyte and eighty-one lymphocyte subpopulation counts were obtained from thirty-one patients who required (VV-ECMO, N = 13) or not (no VV-ECMO, N = 18) extracorporeal support. In both groups, treatment with Steroids + Tocilizumab was independently associated with a significant reduction of 46% and 67% in total lymphocytes, 22% and 60% in CD3+, and 61% and 91% in CD19+ (B lymphocytes) compared to those obtained without treatment, respectively. In the no VV-ECMO group, Tocilizumab was associated with a 79% increase in total lymphocytes and with a reduction in procalcitonin compared to no treatment. CD45+, CD3+CD4+ (Th cell), CD3+CD8+, CD4+/CD8+, the NK cell subpopulation, neutrophils, monocytes, and basophils were significantly reduced by Steroids + Tocilizumab without an effect modification by VV-ECMO support. In critically ill COVID-19 patients with ARDS, concomitant therapies with steroids and Tocilizumab, beside mitigating the inflammation and fibrinolysis, could reduce the total leukocyte, lymphocyte, and subpopulation count. Moreover, the effect of Tocilizumab in increasing the total lymphocytes and reducing procalcitonin might be blunted by VV-ECMO

    Cardiac magnetic resonance findings predict increased resource utilization in elective coronary artery bypass grafting

    Get PDF
    Morbidity following CABG (coronary artery bypass grafting) is difficult to predict and leads to increased healthcare costs. We hypothesized that pre-operative CMR (cardiac magnetic resonance) findings would predict resource utilization in elective CABG. Over a 12-month period, patients requiring elective CABG were invited to undergo CMR 1 day prior to CABG. Gadolinium-enhanced CMR was performed using a trueFISP inversion recovery sequence on a 1.5 tesla scanner (Sonata; Siemens). Clinical data were collected prospectively. Admission costs were quantified based on standardized actual cost/day. Admission cost greater than the median was defined as 'increased'. Of 458 elective CABG cases, 45 (10%) underwent pre-operative CMR. Pre-operative characteristics [mean (S.D.) age, 64 (9) years, mortality (1%) and median (interquartile range) admission duration, 7 (6–8) days] were similar in patients who did or did not undergo CMR. In the patients undergoing CMR, eight (18%) and 11 (24%) patients had reduced LV (left ventricular) systolic function by CMR [LVEF (LV ejection fraction) <55%] and echocardiography respectively. LE (late enhancement) with gadolinium was detected in 17 (38%) patients. The average cost/day was 2723.Themedian(interquartilerange)admissioncostwas2723. The median (interquartile range) admission cost was 19059 ($10891–157917). CMR LVEF {OR (odds ratio), 0.93 [95% CI (confidence interval), 0.87–0.99]; P=0.03} and SV (stroke volume) index [OR 1.07 (95% CI, 1.00–1.14); P=0.02] predicted increased admission cost. CMR LVEF (P=0.08) and EuroScore tended to predict actual admission cost (P=0.09), but SV by CMR (P=0.16) and LV function by echocardiography (P=0.95) did not. In conclusion, in this exploratory investigation, pre-operative CMR findings predicted admission duration and increased admission cost in elective CABG surgery. The cost-effectiveness of CMR in risk stratification in elective CABG surgery merits prospective assessment

    Clinical data for paediatric research: the Swiss approach : Proceedings of the National Symposium in Bern, Switzerland, Dec 5-6, 2019.

    Get PDF
    Continuous improvement of health and healthcare system is hampered by inefficient processes of generating new evidence, particularly in the case of rare diseases and paediatrics. Currently, most evidence is generated through specific research projects, which typically require extra encounters with patients, are costly and entail long delays between the recognition of specific needs in healthcare and the generation of necessary evidence to address those needs. The Swiss Personalised Health Network (SPHN) aims to improve the use of data obtained during routine healthcare encounters by harmonizing data across Switzerland and facilitating accessibility for research. The project "Harmonising the collection of health-related data and biospecimens in paediatric hospitals throughout Switzerland (SwissPedData)" was an infrastructure development project funded by the SPHN, which aimed to identify and describe available data on child health in Switzerland and to agree on a standardised core dataset for electronic health records across all paediatric teaching hospitals. Here, we describe the results of a two-day symposium that aimed to summarise what had been achieved in the SwissPedData project, to put it in an international context, and to discuss the next steps for a sustainable future. The target audience included clinicians and researchers who produce and use health-related data on children in Switzerland. The symposium consisted of state-of-the-art lectures from national and international keynote speakers, workshops and plenary discussions. This manuscript summarises the talks and discussions in four sections: (I) a description of the Swiss Personalized Health Network and the results of the SwissPedData project; (II) examples of similar initiatives from other countries; (III) an overview of existing health-related datasets and projects in Switzerland; and (IV) a summary of the lessons learned and future prospective from workshops and plenary discussions. Streamlined processes linking initial collection of information during routine healthcare encounters, standardised recording of this information in electronic health records and fast accessibility for research are essential to accelerate research in child health and make it affordable. Ongoing projects prove that this is feasible in Switzerland and elsewhere. International collaboration is vital to success. The next steps include the implementation of the SwissPedData core dataset in the clinical information systems of Swiss hospitals, the use of this data to address priority research questions, and the acquisition of sustainable funding to support a slim central infrastructure and local support in each hospital. This will lay the foundation for a national paediatric learning health system in Switzerland

    Optical and radio behaviour of the BL Lacertae object 0716+714

    Get PDF
    Eight optical and four radio observatories have been intensively monitoring the BL Lac object 0716+714 in the last years: 4854 data points have been collected in the UBVRI bands since 1994, while radio light curves extend back to 1978. Many of these data are presented here for the first time. The long-term trend shown by the optical light curves seems to vary with a characteristic time scale of about 3.3 years, while a longer period of 5.5-6 years seems to characterize the radio long-term variations. In general, optical colour indices are only weakly correlated with brightness. The radio flux behaviour at different frequencies is similar, but the flux variation amplitude decreases with increasing wavelength. The radio spectral index varies with brightness (harder when brighter), but the radio fluxes seem to be the sum of two different-spectrum contributions: a steady base level and a harder-spectrum variable component. Once the base level is removed, the radio variations appear as essentially achromatic, similarly to the optical behaviour. Flux variations at the higher radio frequencies lead the lower-frequency ones with week-month time scales. The behaviour of the optical and radio light curves is quite different, the broad radio outbursts not corresponding in time to the faster optical ones and the cross-correlation analysis indicating only weak correlation with long time lags. However, minor radio flux enhancements simultaneous with the major optical flares can be recognized, which may imply that the mechanism producing the strong flux increases in the optical band also marginally affects the radio one.Comment: 18 pages, 15 Postscript figures, 5 JPEG figures, accepted for publication in A&

    Multiwavelength Intraday Variability of the BL Lac S5 0716+714

    Full text link
    We report results from a 1 week multi-wavelength campaign to monitor the BL Lac object S5 0716+714 (on December 9-16, 2009). In the radio bands the source shows rapid (~ (0.5-1.5) day) intra-day variability with peak amplitudes of up to ~ 10 %. The variability at 2.8 cm leads by about 1 day the variability at 6 cm and 11 cm. This time lag and more rapid variations suggests an intrinsic contribution to the source's intraday variability at 2.8 cm, while at 6 cm and 11 cm interstellar scintillation (ISS) seems to predominate. Large and quasi-sinusoidal variations of ~ 0.8 mag were detected in the V, R and I-bands. The X-ray data (0.2-10 keV) do not reveal significant variability on a 4 day time scale, favoring reprocessed inverse-Compton over synchrotron radiation in this band. The characteristic variability time scales in radio and optical bands are similar. A quasi-periodic variation (QPO) of 0.9 - 1.1 days in the optical data may be present, but if so it is marginal and limited to 2.2 cycles. Cross-correlations between radio and optical are discussed. The lack of a strong radio-optical correlation indicates different physical causes of variability (ISS at long radio wavelengths, source intrinsic origin in the optical), and is consistent with a high jet opacity and a compact synchrotron component peaking at ~= 100 GHz in an ongoing very prominent flux density outburst. For the campaign period, we construct a quasi-simultaneous spectral energy distribution (SED), including gamma-ray data from the FERMI satellite. We obtain lower limits for the relativistic Doppler-boosting of delta >= 12-26, which for a BL\,Lac type object, is remarkably high.Comment: 16 pages, 15 figures, table 2; Accepted for Publication in MNRA

    Optical Intraday Variability Studies of Ten Low Energy Peaked Blazars

    Full text link
    We have carried out optical (R band) intraday variability (IDV) monitoring of a sample of ten bright low energy peaked blazars (LBLs). Forty photometric observations, of an average of ~ 4 hours each, were made between 2008 September and 2009 June using two telescopes in India. Measurements with good signal to noise ratios were typically obtained within 1-3 minutes, allowing the detection of weak, fast variations using N-star differential photometry. We employed both structure function and discrete correlation function analysis methods to estimate any dominant timescales of variability and found that in most of the cases any such timescales were longer than the duration of the observation. The calculated duty cycle of IDV in LBLs during our observing run is ~ 52%, which is low compared to many earlier studies; however, the relatively short periods for which each source was observed can probably explain this difference. We briefly discuss possible emission mechanisms for the observed variability.Comment: 20 Pages, 9 Figures, 4 Tables, accepted for publication in MNRA

    Position of eukaryotic translation initiation factor eIF1A on the 40S ribosomal subunit mapped by directed hydroxyl radical probing

    Get PDF
    The universally conserved eukaryotic initiation factor (eIF), eIF1A, plays multiple roles throughout initiation: it stimulates eIF2/GTP/Met-tRNAiMet attachment to 40S ribosomal subunits, scanning, start codon selection and subunit joining. Its bacterial ortholog IF1 consists of an oligonucleotide/oligosaccharide-binding (OB) domain, whereas eIF1A additionally contains a helical subdomain, N-terminal tail (NTT) and C-terminal tail (CTT). The NTT and CTT both enhance ribosomal recruitment of eIF2/GTP/Met-tRNAiMet, but have opposite effects on the stringency of start codon selection: the CTT increases, whereas the NTT decreases it. Here, we determined the position of eIF1A on the 40S subunit by directed hydroxyl radical cleavage. eIF1A's OB domain binds in the A site, similar to IF1, whereas the helical subdomain contacts the head, forming a bridge over the mRNA channel. The NTT and CTT both thread under Met-tRNAiMet reaching into the P-site. The NTT threads closer to the mRNA channel. In the proposed model, the NTT does not clash with either mRNA or Met-tRNAiMet, consistent with its suggested role in promoting the ‘closed’ conformation of ribosomal complexes upon start codon recognition. In contrast, eIF1A-CTT appears to interfere with the P-site tRNA-head interaction in the ‘closed’ complex and is likely ejected from the P-site upon start codon recognition
    • 

    corecore