328 research outputs found

    Cabbage and fermented vegetables : From death rate heterogeneity in countries to candidates for mitigation strategies of severe COVID-19

    Get PDF
    Large differences in COVID-19 death rates exist between countries and between regions of the same country. Some very low death rate countries such as Eastern Asia, Central Europe, or the Balkans have a common feature of eating large quantities of fermented foods. Although biases exist when examining ecological studies, fermented vegetables or cabbage have been associated with low death rates in European countries. SARS-CoV-2 binds to its receptor, the angiotensin-converting enzyme 2 (ACE2). As a result of SARS-CoV-2 binding, ACE2 downregulation enhances the angiotensin II receptor type 1 (AT(1)R) axis associated with oxidative stress. This leads to insulin resistance as well as lung and endothelial damage, two severe outcomes of COVID-19. The nuclear factor (erythroid-derived 2)-like 2 (Nrf2) is the most potent antioxidant in humans and can block in particular the AT(1)R axis. Cabbage contains precursors of sulforaphane, the most active natural activator of Nrf2. Fermented vegetables contain many lactobacilli, which are also potent Nrf2 activators. Three examples are: kimchi in Korea, westernized foods, and the slum paradox. It is proposed that fermented cabbage is a proof-of-concept of dietary manipulations that may enhance Nrf2-associated antioxidant effects, helpful in mitigating COVID-19 severity.Peer reviewe

    Nrf2-interacting nutrients and COVID-19 : time for research to develop adaptation strategies

    Get PDF
    There are large between- and within-country variations in COVID-19 death rates. Some very low death rate settings such as Eastern Asia, Central Europe, the Balkans and Africa have a common feature of eating large quantities of fermented foods whose intake is associated with the activation of the Nrf2 (Nuclear factor (erythroid-derived 2)-like 2) anti-oxidant transcription factor. There are many Nrf2-interacting nutrients (berberine, curcumin, epigallocatechin gallate, genistein, quercetin, resveratrol, sulforaphane) that all act similarly to reduce insulin resistance, endothelial damage, lung injury and cytokine storm. They also act on the same mechanisms (mTOR: Mammalian target of rapamycin, PPAR gamma:Peroxisome proliferator-activated receptor, NF kappa B: Nuclear factor kappa B, ERK: Extracellular signal-regulated kinases and eIF2 alpha:Elongation initiation factor 2 alpha). They may as a result be important in mitigating the severity of COVID-19, acting through the endoplasmic reticulum stress or ACE-Angiotensin-II-AT(1)R axis (AT(1)R) pathway. Many Nrf2-interacting nutrients are also interacting with TRPA1 and/or TRPV1. Interestingly, geographical areas with very low COVID-19 mortality are those with the lowest prevalence of obesity (Sub-Saharan Africa and Asia). It is tempting to propose that Nrf2-interacting foods and nutrients can re-balance insulin resistance and have a significant effect on COVID-19 severity. It is therefore possible that the intake of these foods may restore an optimal natural balance for the Nrf2 pathway and may be of interest in the mitigation of COVID-19 severity

    Multicentric survey of patient doses in fluoroscopy guided diagnostic and interventional cardiac procedures: comparison with Diagnostic Reference Levels and follow-up levels for patients at risk for radiation induced skin effects

    No full text
    Въведение. Интервенционалните кардиологични процедури, често са свързани с голямо облъчване на пациентите, поради което изискват специално внимание по отношение на защитата от появата на радиационно индуцирани ефекти при пациента.Материали и методи. Проучването на типичните стойности на дозата е проведено ретроспективно, в девет лечебни заведения, с общо четиринадесет ангиографски уредби. За две от най-често извършваните процедури - перкутанна коронарна интервенция (PCI) и коронарна артериография (CA) са изчислени типичните стойности на величините произведение керма-площ (КАП), кумулативна доза (КД) и време на скопия (ВС) и са сравнени с актуалните Национални диагностични референтни нива (НДРН) за България. Извършен е анализ на данните по отношение на риска от възникване на кожно индуцирани ефекти, вследствие на интервенционалните кардиологични процедури.Цел. 1) да се представят и анализират типичните стойности на величината КАП за най-често провежданите кардиологични процедури - перкутанна коронарна интервенция и коронарна артериография в кардиологични отделения с голяма работна натовареност и да се сравнят с НДРН; 2) да се сравнят дозите на пациентите с публикуваните в Наредба 2 нива за проследяване, за установяване на пациенти с риск за възникване на радиационно индуцирани ефекти.Резултати. Резултатите показват, че типични стойности на изследваните величини за PCI и CA при някои от уредбите, са по-високи от НДРН. Във всяко от разглежданите лечебни заведения има пациенти с поне едно превишено ниво за проследяване за процедура PCI.Изводи. Резултатите показват потенциал за оптимизиране, както на работата в отделенията с високи типични стойности на дозата, така и при уредбите с много ниски типични стойности на изследваните величини. При проследените пациенти не се наблюдават оплаквания и поява на радиационно индуциран ефект. Изготвянето и въвеждането в рутинната клинична практика на процедури за рутинно прилагане на „Инструкцията за пациента след проведена интервенционална/и процедура/и с по-голяма степен на сложност и дълго време на скопия“ ще позволи навременна диагностика и навременно лечение на кожните ефекти в следствие на проведените кардиологични процедури под рентгенов контрол. Introduction. Interventional cardiac procedures are often associated with high patient exposure and therefore require special care in protecting patients from radiation-induced effects.Materials and methods. A retrospective study of typical patients’doses was performed in nine hospitals, with a total number of fourteen angiography systems. The typical values for kerma-area product (KAP), cumulative dose (CD) and fluoroscopy time (FT) for two of the most commonly performed procedures - percutaneous coronary intervention (PCI) and coronary arteriography (CA), were calculated and compared with the Bulgarian National Diagnostic Reference Levels (NDRL). Data analysis, regarding the risk of radiation-induced skin effects due to interventional cardiac procedures, was performed.Aim. 1) to present and analyze the typical KAP values for PCI and CA procedures in cardiology departments with high workload and to compare them with the NDRL; 2) to compare the patient doses with the follow-up levels published in Ordinance 2, to identify patients at risk for radiation-induced effects.Results. The results show that typical values for PCI and CA procedures for some of the angiography systems are higher than the NDRL. In all investigated departments there are patients with at least one exceeded follow-up level for PCI.Conclusions. The results show a potential for optimization in the departments with both high or very low typical dose or FT values. No radiation-induced effect was observed in the followed-up group of patients. The introduction of procedure with "Instruction to the patient after an interventional cardiac procedure(s) with greater complexity and a long fluoroscopy time" for patient follow-up and its regular implementation into the routine clinical practice will help for timely diagnosis and treatment of radiation-induced skin effects after cardiac procedures under fluoroscopy control

    Is diet partly responsible for differences in COVID-19 death rates between and within countries?

    No full text

    Pseudorapidity densities of charged particles with transverse momentum thresholds in pp collisions at √ s = 5.02 and 13 TeV

    No full text
    The pseudorapidity density of charged particles with minimum transverse momentum (pT) thresholds of 0.15, 0.5, 1, and 2 GeV/c is measured in pp collisions at the center of mass energies of √s=5.02 and 13 TeV with the ALICE detector. The study is carried out for inelastic collisions with at least one primary charged particle having a pseudorapidity (η) within 0.8pT larger than the corresponding threshold. In addition, measurements without pT-thresholds are performed for inelastic and nonsingle-diffractive events as well as for inelastic events with at least one charged particle having |η|2GeV/c), highlighting the importance of such measurements for tuning event generators. The new measurements agree within uncertainties with results from the ATLAS and CMS experiments obtained at √s=13TeV.

    Higher-order correlations between different moments of two flow amplitudes in Pb-Pb collisions at sNN=5.02\sqrt{s_{\rm NN}}=5.02 TeV

    No full text
    International audienceThe correlations between different moments of two flow amplitudes, extracted with the recently developed asymmetric cumulants, are measured in Pb-Pb collisions at sNN=5.02\sqrt{s_{\rm NN}} = 5.02 TeV recorded by the ALICE detector at the LHC. The magnitudes of the measured observables show a dependence on the different moments as well as on the collision centrality, indicating the presence of non-linear response in all even moments up to the eighth. Furthermore, the higher-order asymmetric cumulants show different signatures than the symmetric and lower-order asymmetric cumulants. Comparisons with state-of-the-art event generators using two different parameterizations obtained from Bayesian optimization show differences between data and simulations in many of the studied observables, indicating a need for further tuning of the models behind those event generators. These results provide new and independent constraints on the initial conditions and transport properties of the system created in heavy-ion collisions

    First measurement of the t|t|-dependence of incoherent J/ψ\psi photonuclear production

    No full text
    International audienceThe first measurement of the cross section for incoherent photonuclear production of J/ψ\psi vector meson as a function of the Mandelstam t|t| variable is presented. The measurement was carried out with the ALICE detector at midrapidity, y<0.8|y|<0.8, using ultra-peripheral collisions of Pb nuclei at a centre-of-mass energy per nucleon pair sNN=5.02\sqrt{s_{\mathrm{NN}}} = 5.02 TeV. This rapidity interval corresponds to a Bjorken-xx range (0.3(0.3-1.4)×1031.4)\times 10^{-3}. Cross sections are reported in five t|t| intervals in the range 0.04<t<10.04<|t|<1~GeV2^2 and compared to the predictions of different models. Models that ignore quantum fluctuations of the gluon density in the colliding hadron predict a t|t|-dependence of the cross section much steeper than in data. The inclusion of such fluctuations in the same models provides a better description of the data

    Data-driven precision determination of the material budget in ALICE

    No full text
    The knowledge of the material budget with a high precision is fundamental for measurements of direct photon production using the photon conversion method due to its direct impact on the total systematic uncertainty. Moreover, it influences many aspects of the charged-particle reconstruction performance. In this article, two procedures to determine data-driven corrections to the material-budget description in ALICE simulation software are developed. One is based on the precise knowledge of the gas composition in the Time Projection Chamber. The other is based on the robustness of the ratio between the produced number of photons and charged particles, to a large extent due to the approximate isospin symmetry in the number of produced neutral and charged pions. Both methods are applied to ALICE data allowing for a reduction of the overall material budget systematic uncertainty from 4.5% down to 2.5%. Using these methods, a locally correct material budget is also achieved. The two proposed methods are generic and can be applied to any experiment in a similar fashion.The knowledge of the material budget with a high precision is fundamental for measurements of direct photon production using the photon conversion method due to its direct impact on the total systematic uncertainty. Moreover, it influences many aspects of the charged-particle reconstruction performance. In this article, two procedures to determine data-driven corrections to the material-budget description in ALICE simulation software are developed. One is based on the precise knowledge of the gas composition in the Time Projection Chamber. The other is based on the robustness of the ratio between the produced number of photons and charged particles, to a large extent due to the approximate isospin symmetry in the number of produced neutral and charged pions. Both methods are applied to ALICE data allowing for a reduction of the overall material budget systematic uncertainty from 4.5% down to 2.5%. Using these methods, a locally correct material budget is also achieved. The two proposed methods are generic and can be applied to any experiment in a similar fashion

    Measurement of Non-prompt D0\rm D^0-meson Elliptic Flow in Pb-Pb Collisions at sNN\sqrt{s_{\rm NN}} = 5.02 TeV

    No full text
    International audienceThe elliptic flow (v2v_2) of D0\rm D^0 mesons from beauty-hadron decays (non-prompt D0\rm D^0) was measured in midcentral (30-50%) Pb-Pb collisions at a centre-of-mass energy per nucleon pair sNN\sqrt{s_{\rm NN}} = 5.02 TeV with the ALICE detector at the LHC. The D0\rm D^0 mesons were reconstructed at midrapidity (y<0.8|y|<0.8) from their hadronic decay D0Kπ+\mathrm{D^0 \to K^-\pi^+}, in the transverse momentum interval 2<pT<122 < p_{\rm T} < 12 GeV/cc. The result indicates a positive v2v_2 for non-prompt D0\rm D^0 mesons with a significance of 2.7σ\sigma. The non-prompt D0\rm D^0-meson v2v_2 is lower than that of prompt non-strange D mesons with 3.2σ\sigma significance in 2<pT<82 < p_{\rm T} < 8 GeV/cc, and compatible with the v2v_2 of beauty-decay electrons. Theoretical calculations of beauty-quark transport in a hydrodynamically expanding medium describe the measurement within uncertainties
    corecore