188 research outputs found

    Inadequate medical treatment of patients with coronary artery disease by primary care physicians in Germany

    Get PDF
    Aims: The DETECT study was performed to obtain representative data about the frequency, distribution, and treatment of patients with coronary artery disease (CAD) in the primary care setting in Germany. Methods and results: The DETECT study was a cross–sectional clinical– epidemiological survey of a nationally representative sample of 3795 primary care offices and 55 518 patients. Overall, 12.4% of patients were diagnosed with CAD. Stable angina pectoris and myocardial infarction were the most frequent (4.2%) subgroups, followed by status post (s/p) percutaneous coronary interventions (PCI, 3.0%) and s/p coronary bypass surgery (2.2%). Patients with CAD were prescribed AT1 receptor antagonists (in 19.4% of cases), beta blockers (57.2%), ACE inhibitors (49.9%), antiplatelet agents (52.7%), statins (43.0%), and long–term nitrates (24.5%). When comparing all CAD patients with social health care insurance to those who had private insurance, private patients had significantly higher rates of revascularisation procedures and use of preventive medications. Conclusion: Great potential remains for improving secondary prevention in primary care in Germany to reduce the risk of further coronary or vascular events, especially in patients with social health care insurance

    НАУКОВІ ДОСЛІДЖЕННЯ ВЧЕНИХ КВГУ-КГІ-ДГІ В ГАЛУЗІ МЕТАЛУРГІЇ (1900-1930 рр.)

    Get PDF
    Перші зародки промислового вуглевидобутку на Півдні Російської імперії (Лисячий Байрак під Лисичанськом) і виробництва металу (м. Луганськ) виник-ли у 90-х роках ХVІІІ с. У наступні десятиліття ці взаємопов’язані галузі розвивалися дуже повільно. А трохи раніше спроба почати видобуток залізної руди і виплавку з неї гарматних ядер на Криворіжжі була невдалою, тому майже на сто років про ці поклади руд забули

    Lack of association between dual antiplatelet therapy use and stent thrombosis between 1 and 12 months following resolute zotarolimus-eluting stent implantation

    Get PDF
    Aim The optimal duration of dual antiplatelet therapy (DAPT) following the use of new generation drug-eluting stents is unknown. Methods and results The association between DAPT interruption and the rates of stent thrombosis (ST) and cardiac death/target-vessel myocardial infarction (CD/TVMI) in patients receiving a Resolute zotarolimus-eluting stent (R-ZES) was analysed in 4896 patients from the pooled RESOLUTE clinical programme. Daily acetylsalicylate (ASA) and a thienopyridine for 6-12 months were prescribed. A DAPT interruption was defined as any interruption of ASA and/or a thienopyridine of >1 day; long interruptions were >14 days. Three groups were analysed: no interruption, interruption during the first month, and >1-12 months. There were 1069 (21.83%) patients with a DAPT interruption and 3827 patients with no interruption. Among the 166 patients in the 1-month interruption group, 6 definite/probable ST events occurred (3.61%; all long DAPT interruptions), and among the 903 patients in the >1-12 months (60% occurred between 6 and 12 months) interruption group, 1 ST event occurred (0.11%; 2-day DAPT interruption). Among patients with no DAPT interruption, 32 ST events occurred (0.84%). Rates of CD/TVMI were 6.84% in the 1-month long interruption group, 1.41% in the >1-12 months long interruption group, and 4.08% in patients on continuous DAPT. Conclusion In a pooled population of patients receiving an R-ZES, DAPT interruptions within 1 month are associated with a high risk of adverse outcomes. Dual antiplatelet therapy interruptions between 1 and 12 months were associated with low rates of ST and adverse cardiac outcomes. Randomized clinical trials are needed to determine whether early temporary or permanent interruption of DAPT is truly safe. Clinical Trials.gov identifiers NCT00617084; NCT00726453; NCT00752128; NCT0092794

    Changes in the prevalence, treatment and control of hypertension in Germany? : a clinical-epidemiological study of 50.000 primary care patients

    Get PDF
    INTRODUCTION: Medical societies have developed guidelines for the detection, treatment and control of hypertension (HTN). Our analysis assessed the extent to which such guidelines were implemented in Germany in 2003 and 2001. METHODS: Using standardized clinical diagnostic and treatment appraisal forms, blood pressure levels and patient questionnaires for 55,518 participants from the cross-sectional Targets and Essential Data for Commitment of Treatment (DETECT) study (2003) were analyzed. Physician's diagnosis of hypertension (HTN(doc)) was defined as coding hypertension in the clinical appraisal questionnaire. Alternative definitions used were physician's diagnosis or the patient's self-reported diagnosis of hypertension (HTN(doc,pat)), physician's or patient's self-reported diagnosis or a BP measurement with a systolic BP≥140 mmHg and/or a diastolic BP≥90 (HTN(doc,pat,bp)) and diagnosis according to the National Health and Nutrition Examination Survey (HTN(NHANES)). The results were compared with the similar German HYDRA study to examine whether changes had occurred in diagnosis, treatment and adequate blood pressure control (BP below 140/90 mmHg) since 2001. Factors associated with pharmacotherapy and control were determined. RESULTS: The overall prevalence rate for hypertension was 35.5% according to HTN(doc) and 56.0% according to NHANES criteria. Among those defined by NHANES criteria, treatment and control rates were 56.0% and 20.3% in 2003, and these rates had improved from 55.3% and 18.0% in 2001. Significant predictors of receiving antihypertensive medication were: increasing age, female sex, obesity, previous myocardial infarction and the prevalence of comorbid conditions such as coronary heart disease (CHD), hyperlipidemia and diabetes mellitus (DM). Significant positive predictors of adequate blood pressure control were CHD and antihypertensive medication. Inadequate control was associated with increasing age, male sex and obesity. CONCLUSIONS: Rates of treated and controlled hypertension according to NHANES criteria in DETECT remained low between 2001 and 2003, although there was some minor improvement

    Comparison of zotarolimus- and everolimus-eluting coronary stents: final 5-year report of the RESOLUTE all-comers trial

    Get PDF
    BACKGROUND Newer-generation drug-eluting stents that release zotarolimus or everolimus have been shown to be superior to the first-generation drug-eluting stents. However, data comparing long-term safety and efficacy of zotarolimus- (ZES) and everolimus-eluting stents (EES) are limited. RESOLUTE all-comers (Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention) trial compared these 2 stents and has shown that ZES was noninferior to EES at 12-month for the primary end point of target lesion failure. We report the secondary clinical outcomes at the final 5-year follow-up of this trial. METHODS AND RESULTS RESOLUTE all-comer clinical study is a prospective, multicentre, randomized, 2-arm, open-label, noninferiority trial with minimal exclusion criteria. Patients (n=2292) were randomly assigned to treatment with either ZES (n=1140) or EES (n=1152). Patient-oriented composite end point (combination of all-cause mortality, myocardial infarction, and any revascularizations), device-oriented composite end point (combination of cardiac death, target vessel myocardial infarction, and clinically indicated target lesion revascularization), and major adverse cardiac events (combination of all-cause death, all myocardial infarction, emergent coronary bypass surgery, or clinically indicated target lesion revascularization) were analyzed at 5-year follow-up. The 2 groups were well-matched at baseline. Five-year follow-up data were available for 98% patients. There were no differences in patient-oriented composite end point (ZES 35.3% versus EES 32.0%, P=0.11), device-oriented composite end point (ZES 17.0% versus EES 16.2%, P=0.61), major adverse cardiac events (ZES 21.9% versus EES 21.6%, P=0.88), and definite/probable stent thrombosis (ZES 2.8% versus EES 1.8%, P=0.12). CONCLUSIONS At 5-year follow-up, ZES and EES had similar efficacy and safety in a population of patients who had minimal exclusion criteria. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT00617084

    Development of Complex Mathematical Model of Light Naphtha Isomerization and Rectification Processes

    Get PDF
    The technique of developing a mathematical model of catalytic isomerization of light naphtha is stated Using experimental data from an industrial isomerization unit shows adequacy of the mathematical model to the real process. The paper presents a method for optimizing the operation of the plant together with catalytic isomerization unit and separation columns. Selection of optimal modes of separation columns allows achieving the desired flow separation between units, as well as extension of the life of the catalyst SI-2

    Tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent vs. a fluoropolymer-coated everolimus-eluting stent at 13-month follow-up: an optical coherence tomography substudy from the RESOLUTE All Comers trial

    Get PDF
    Aims To compare the tissue coverage of a hydrophilic polymer-coated zotarolimus-eluting stent (ZES) vs. a fluoropolymer-coated everolimus-eluting stent (EES) at 13 months, using optical coherence tomography (OCT) in an ‘all-comers' population of patients, in order to clarify the mechanism of eventual differences in the biocompatibility and thrombogenicity of the devices. Methods and results Patients randomized to angiographic follow-up in the RESOLUTE All Comers trial (NCT00617084) at pre-specified OCT sites underwent OCT follow-up at 13 months. Tissue coverage and apposition were assessed strut by strut, and the results in both treatment groups were compared using multilevel logistic or linear regression, as appropriate, with clustering at three different levels: patient, lesion, and stent. Fifty-eight patients (30 ZES and 28 EES), 72 lesions, 107 stents, and 23 197 struts were analysed. Eight hundred and eighty-seven and 654 uncovered struts (7.4 and 5.8%, P= 0.378), and 216 and 161 malapposed struts (1.8 and 1.4%, P= 0.569) were found in the ZES and EES groups, respectively. The mean thickness of coverage was 116 ± 99 µm in ZES and 142 ± 113 µm in EES (P= 0.466). No differences in per cent neointimal volume obstruction (12.5 ± 7.9 vs. 15.0 ± 10.7%) or other areas-volumetric parameters were found between ZES and EES, respectively. Conclusion No significant differences in tissue coverage, malapposition, or lumen/stent areas and volumes were detected by OCT between the hydrophilic polymer-coated ZES and the fluoropolymer-coated EES at 13-month follow-u
    corecore