20 research outputs found

    Impact of introducing practical obstetric multi-professional training (PROMPT) into maternity units in Victoria, Australia

    Get PDF
    Objective: To assess the introduction of Practical Obstetric Multi-professional Training (PROMPT) into maternity units and evaluate effects on organisational culture and perinatal outcomes. Design: A retrospective cohort study. Setting: Maternity units in eight public hospitals in metropolitan and regional Victoria, Australia. Population: Staff in eight maternity units and a total of 43 408 babies born between July 2008 and December 2011. Methods: Representatives from eight Victorian hospitals underwent a single day of training (Train the Trainer), to conduct PROMPT. Organisational culture was compared before and after PROMPT. Clinical outcomes were evaluated before, during and after PROMPT. Main outcome measures: The number of courses run and the proportion of staff trained were determined. Organisational culture was measured using the Safety Attitude Questionnaire. Clinical measures included Apgar scores at 1 and 5 minutes (Apgar 1 and Apgar 5), cord lactate, blood loss and length of baby's stay in hospital. Results: Seven of the eight hospitals conducted PROMPT. Overall about 50% of staff were trained in each year of the study. Significant increases were found in Safety Attitude Questionnaire scores representing domains of teamwork (Hedges' g 0.27, 95% confidence interval [95% CI] 0.13-0.41), safety (Hedges' g 0.28, 95% CI 0.15-0.42) and perception of management (Hedges' g 0.17, 95% CI 0.04-0.31). There were significant improvements in Apgar 1 (OR 0.84, 95% CI 0.77-0.91), cord lactates (odds ratio 0.92, 95% CI 0.85-0.99) and average length of baby's stay in hospital (Hedges' g 0.03, 95% CI 0.01-0.05) during or after training, but no change in Apgar 5 scores or proportion of cases with high blood loss. Conclusion: PROMPT can be introduced using the Train the Trainer model. Improvements in organisational culture and some clinical measures were observed following PROMPT

    Assessing hearing by measuring heartbeat: The effect of sound level.

    Get PDF
    Functional near-infrared spectroscopy (fNIRS) is a non-invasive brain imaging technique that measures changes in oxygenated and de-oxygenated hemoglobin concentration and can provide a measure of brain activity. In addition to neural activity, fNIRS signals contain components that can be used to extract physiological information such as cardiac measures. Previous studies have shown changes in cardiac activity in response to different sounds. This study investigated whether cardiac responses collected using fNIRS differ for different loudness of sounds. fNIRS data were collected from 28 normal hearing participants. Cardiac response measures evoked by broadband, amplitude-modulated sounds were extracted for four sound intensities ranging from near-threshold to comfortably loud levels (15, 40, 65 and 90 dB Sound Pressure Level (SPL)). Following onset of the noise stimulus, heart rate initially decreased for sounds of 15 and 40 dB SPL, reaching a significantly lower rate at 15 dB SPL. For sounds at 65 and 90 dB SPL, increases in heart rate were seen. To quantify the timing of significant changes, inter-beat intervals were assessed. For sounds at 40 dB SPL, an immediate significant change in the first two inter-beat intervals following sound onset was found. At other levels, the most significant change appeared later (beats 3 to 5 following sound onset). In conclusion, changes in heart rate were associated with the level of sound with a clear difference in response to near-threshold sounds compared to comfortably loud sounds. These findings may be used alone or in conjunction with other measures such as fNIRS brain activity for evaluation of hearing ability

    Objective measurement of tinnitus using functional near-infrared spectroscopy and machine learning

    Get PDF
    Chronic tinnitus is a debilitating condition which affects 10-20% of adults and can severely impact their quality of life. Currently there is no objective measure of tinnitus that can be used clinically. Clinical assessment of the condition uses subjective feedback from individuals which is not always reliable. We investigated the sensitivity of functional near-infrared spectroscopy (fNIRS) to differentiate individuals with and without tinnitus and to identify fNIRS features associated with subjective ratings of tinnitus severity. We recorded fNIRS signals in the resting state and in response to auditory or visual stimuli from 25 individuals with chronic tinnitus and 21 controls matched for age and hearing loss. Severity of tinnitus was rated using the Tinnitus Handicap Inventory and subjective ratings of tinnitus loudness and annoyance were measured on a visual analogue scale. Following statistical group comparisons, machine learning methods including feature extraction and classification were applied to the fNIRS features to classify patients with tinnitus and controls and differentiate tinnitus at different severity levels. Resting state measures of connectivity between temporal regions and frontal and occipital regions were significantly higher in patients with tinnitus compared to controls. In the tinnitus group, temporal-occipital connectivity showed a significant increase with subject ratings of loudness. Also in this group, both visual and auditory evoked responses were significantly reduced in the visual and auditory regions of interest respectively. Naïve Bayes classifiers were able to classify patients with tinnitus from controls with an accuracy of 78.3%. An accuracy of 87.32% was achieved using Neural Networks to differentiate patients with slight/ mild versus moderate/ severe tinnitus. Our findings show the feasibility of using fNIRS and machine learning to develop an objective measure of tinnitus. Such a measure would greatly benefit clinicians and patients by providing a tool to objectively assess new treatments and patients' treatment progress

    Human factors in information technology

    No full text
    BACKGROUND: Current electroencephalogram (EEG)-derived measures provide information on cortical activity and hypnosis but are less accurate regarding subcortical activity, which is expected to vary with the degree of antinociception. Recently, the neurophysiologically based EEG measures of cortical input (CI) and cortical state (CS) have been shown to be prospective indicators of analgesia/antinociception and hypnosis, respectively. In this study, we compared CI and an alternate measure of CS, the composite cortical state (CCS), with the Bispectral Index (BIS) and another recently developed measure of antinociception, the composite variability index (CVI). CVI is an EEG-derived measure based on a weighted combination of BIS and estimated electromyographic activity. By assessing the relationship between these indices for equivalent levels of hypnosis (as quantified using the BIS) and the nociceptive-antinociceptive balance (as determined by the predicted effect-site concentration of remifentanil), we sought to evaluate whether combining hypnotic and analgesic measures could better predict movement in response to a noxious stimulus than when used alone. METHODS: Time series of BIS and CVI indices and the raw EEG from a previously published study were reanalyzed. In our current study, the data from 80 patients, each randomly allocated to a target hypnotic level (BIS 50 or BIS 70) and a target remifentanil level (Remi-0, -2, -4 or -6 ng/mL), were included in the analysis. CCS, CI, BIS, and CVI were calculated or quantified at baseline and at a number of intervals after the application of the Observer's Assessment of Alertness/Sedation scale and a subsequent tetanic stimulus. The dependency of the putative measures of antinociception CI and CVI on effect-site concentration of remifentanil was then quantified, together with their relationship to the hypnotic measures CCS and BIS. Finally, statistical clustering methods were used to evaluate the extent to which simple combinations of antinociceptive and hypnotic measures could better detect and predict response to stimulation. RESULTS: Before stimulation, both CI and CVI differentiated patients who received remifentanil from those who were randomly allocated to the Remi-0 group (CI: Cohen's d = 0.65, 95% confidence interval, 0.48-0.83; CVI: Cohen's d = 0.72, 95% confidence interval, 0.56-0.88). Strong correlations between BIS and CCS were found (at different periods: 0.55 < R-2 < 0.68, P < 0.001). Application of the Observer's Assessment of Alertness/Sedation stimulus was associated with changes in CI and CCS, whereas, subsequent to the application of both stimuli, changes in all measures were seen. Pairwise combinations of CI and CCS showed higher sensitivity in detecting response to stimulation than CVI and BIS combined (sensitivity [99% confidence interval], 75.8% [52.7%-98.8%] vs 42% [15.4%-68.5%], P = 0.006), with specificity for CI and CCS approaching significance (52% [34.7%-69.3%] vs 24% [9.1%-38.9%], P = 0.0159). CONCLUSIONS: Combining electroencephalographically derived hypnotic and analgesic quantifiers may enable better prediction of patients who are likely to respond to tetanic stimulation
    corecore