49 research outputs found

    Measurement of Wall Shear Stress Exerted by Flowing Blood in the Human Carotid Artery: Ultrasound Doppler Velocimetry and Echo Particle Image Velocimetry

    Get PDF
    This is the author accepted manuscript. The final version is available from Elsevier via the DOI in this recordVascular endothelial cells lining the arteries are sensitive to wall shear stress (WSS) exerted by flowing blood. An important component of the pathophysiology of vascular diseases, WSS is commonly estimated by centerline ultrasound Doppler velocimetry (UDV). However, the accuracy of this method is uncertain. We have previously validated the use of a novel, ultrasound-based, particle image velocimetry technique (echo PIV) to compute 2-D velocity vector fields, which can easily be converted into WSS data. We compared WSS data derived from UDV and echo PIV in the common carotid artery of 27 healthy participants. Compared with echo PIV, time-averaged WSS was lower using UDV (28 ± 35%). Echo PIV revealed that this was due to considerable spatiotemporal variation in the flow velocity profile, contrary to the assumption that flow is steady and the velocity profile is parabolic throughout the cardiac cycle. The largest WSS underestimation by UDV was found during peak systole (118 ± 16%) and the smallest during mid-diastole (4.3± 46%). The UDV method underestimated WSS for the accelerating and decelerating systolic measurements (68 ± 30% and 24 ± 51%), whereas WSS was overestimated for end-diastolic measurements (−44 ± 55%). Our data indicate that UDV estimates of WSS provided limited and largely inaccurate information about WSS and that the complex spatiotemporal flow patterns do not fit well with traditional assumptions about blood flow in arteries. Echo PIV-derived WSS provides detailed information about this important but poorly understood stimulus that influences vascular endothelial pathophysiology.National Institute of HealthNational Institute for Health Research (NIHR

    Sustainable flood risk and stormwater management in blue‐green cities; an interdisciplinary case study in Portland, Oregon

    Get PDF
    Blue-Green Infrastructure (BGI) is recognized as a viable strategy to manage stormwater and flood risk, and its multifunctionality may further enrich society through the provision of multiple cobenefits that extend far beyond the hydrosphere. Portland, Oregon, is an internationally renowned leader in the implementation of BGI and showcases many best practice examples. Nonetheless, a range of interdisciplinary barriers and uncertainties continue to cloud decision making and impede wider implementation of BGI. In this paper, we synthesize research conducted by the “Clean Water for All” (CWfA) research project and demonstrate that interdisciplinary evaluation of the benefits of Portland’s BGI, focusing on green street bioswales and the East Lents Floodplain Restoration Project, is essential to address biophysical and sociopolitical barriers. Effective interdisciplinary approaches require sustained interaction and collaboration to integrate disciplinary expertise toward a common problem-solving purpose, and strong leadership from researchers adapt at spanning disciplinary boundaries. While the disciplinary differences in methodologies were embraced in the CWfA project, and pivotal to providing evidence of the disparate benefits of multifunctional BGI, cross-disciplinary engagement, knowledge coproduction, and data exchanges during the research process were of paramount importance to reduce the potential for fragmentation and ensure research remained integrated. © 2020 The Authors. Journal of the American Water Resources Association published by Wiley Periodicals LLC on behalf of American Water Resources Associatio

    Impact of pericardial adhesions on diastolic function as assessed by vortex formation time, a parameter of transmitral flow efficiency

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Pericardial adhesions are a pathophysiological marker of constrictive pericarditis (CP), which impairs cardiac filling by limiting the total cardiac volume compliance and diastolic filling function. We studied diastolic transmitral flow efficiency as a new parameter of filling function in a pericardial adhesion animal model. We hypothesized that vortex formation time (VFT), an index of optimal efficient diastolic transmitral flow, is altered by patchy pericardial-epicardial adhesions.</p> <p>Methods</p> <p>In 8 open-chest pigs, the heart was exposed while preserving the pericardium. We experimentally simulated early pericardial constriction and patchy adhesions by instilling instant glue into the pericardial space and using pericardial-epicardial stitches. We studied left ventricular (LV) function and characterized intraventricular blood flow with conventional and Doppler echocardiography at baseline and following the experimental intervention.</p> <p>Results</p> <p>Significant decreases in end-diastolic volume, ejection fraction, stroke volume, and late diastolic filling velocity reflected the effects of the pericardial adhesions. The mean VFT value decreased from 3.61 ± 0.47 to 2.26 ± 0.45 (P = 0.0002). Hemodynamic variables indicated the inhibiting effect of pericardial adhesion on both contraction (decrease in systolic blood pressure and +dP/dt decreased) and relaxation (decrease in the magnitude of -dP/dt and prolongation of Tau) function.</p> <p>Conclusion</p> <p>Patchy pericardial adhesions not only negatively impact LV mechanical functioning but the decrease of VFT from normal to suboptimal value suggests impairment of transmitral flow efficiency.</p

    A Genome-Wide Association Study of Diabetic Kidney Disease in Subjects With Type 2 Diabetes

    Get PDF
    dentification of sequence variants robustly associated with predisposition to diabetic kidney disease (DKD) has the potential to provide insights into the pathophysiological mechanisms responsible. We conducted a genome-wide association study (GWAS) of DKD in type 2 diabetes (T2D) using eight complementary dichotomous and quantitative DKD phenotypes: the principal dichotomous analysis involved 5,717 T2D subjects, 3,345 with DKD. Promising association signals were evaluated in up to 26,827 subjects with T2D (12,710 with DKD). A combined T1D+T2D GWAS was performed using complementary data available for subjects with T1D, which, with replication samples, involved up to 40,340 subjects with diabetes (18,582 with DKD). Analysis of specific DKD phenotypes identified a novel signal near GABRR1 (rs9942471, P = 4.5 x 10(-8)) associated with microalbuminuria in European T2D case subjects. However, no replication of this signal was observed in Asian subjects with T2D or in the equivalent T1D analysis. There was only limited support, in this substantially enlarged analysis, for association at previously reported DKD signals, except for those at UMOD and PRKAG2, both associated with estimated glomerular filtration rate. We conclude that, despite challenges in addressing phenotypic heterogeneity, access to increased sample sizes will continue to provide more robust inference regarding risk variant discovery for DKD.Peer reviewe

    Characterization of micro-invasive trabecular bypass stents by ex vivo perfusion and computational flow modeling

    No full text
    Kendall S Hunter,1 Todd Fjield,2 Hal Heitzmann,2 Robin Shandas,1 Malik Y Kahook3 1Department of Bioengineering, University of Colorado Denver, Aurora, CO, USA; 2Glaukos Corporation, Laguna Hills, CA, USA; 3University of Colorado Hospital Eye Center, Aurora, CO, USA Abstract: Micro-invasive glaucoma surgery with the Glaukos iStent&reg; or iStent inject&reg; (Glaukos Corporation, Laguna Hills, CA, USA) is intended to create a bypass through the trabecular meshwork to Schlemm&#39;s canal to improve aqueous outflow through the natural physiologic pathway. While the iStent devices have been evaluated in ex vivo anterior segment models, they have not previously been evaluated in whole eye perfusion models nor characterized by computational fluid dynamics. Intraocular pressure (IOP) reduction with the iStent was evaluated in an ex vivo whole human eye perfusion model. Numerical modeling, including computational fluid dynamics, was used to evaluate the flow through the stents over physiologically relevant boundary conditions. In the ex vivo model, a single iStent reduced IOP by 6.0 mmHg from baseline, and addition of a second iStent further lowered IOP by 2.9 mmHg, for a total IOP reduction of 8.9 mmHg. Computational modeling showed that simulated flow through the iStent or iStent inject is smooth and laminar at physiological flow rates. Each stent was computed to have a negligible flow resistance consistent with an expected significant decrease in IOP. The present perfusion results agree with prior clinical and laboratory studies to show that both iStent and iStent inject therapies are potentially titratable, providing clinicians with the opportunity to achieve lower target IOPs by implanting additional stents. Keywords: glaucoma, iStent, trabecular bypass, intraocular pressure, ab-interno, CF
    corecore