27 research outputs found

    Measurement of directional range components of nuclear recoil tracks in a fiducialised dark matter detector

    Get PDF
    We present results from the first measurement of axial range components of fiducialized neutron induced nuclear recoil tracks using the DRIFT directional dark matter detector. Nuclear recoil events are fiducialized in the DRIFT experiment using temporal charge carrier separations between different species of anions in 30:10:1 Torr of CS2_2:CF4_4:O2_2 gas mixture. For this measurement, neutron-induced nuclear recoil tracks were generated by exposing the detector to 252^{252}Cf source from different directions. Using these events, the sensitivity of the detector to the expected axial directional signatures were investigated as the neutron source was moved from one detector axis to another. Results obtained from these measurements show clear sensitivity of the DRIFT detector to the axial directional signatures in this fiducialization gas mode

    The Drift Directional Dark Matter Experiments

    Get PDF
    The current status of the DRIFT (Directional Recoil Identification From Tracks) experiment at Boulby Mine is presented, including the latest limits on the WIMP spin-dependent cross-section from 1.5 kg days of running with a mixture of CS2 and CF4. Planned upgrades to DRIFT IId are detailed, along with ongoing work towards DRIFT III, which aims to be the world's first 10 m3-scale directional Dark Matter detector

    First measurement of nuclear recoil head-tail sense in a fiducialised WIMP dark matter detector

    Get PDF
    Recent computational results suggest that directional dark matter detectors have potential to probe for WIMP dark matter particles below the neutrino floor. The DRIFT-IId detector used in this work is a leading directional WIMP search time projection chamber detector. We report the first measurements of the detection of the directional nuclear recoils in a fully fiducialised low-pressure time projection chamber. In this new operational mode, the distance between each event vertex and the readout plane is determined by the measurement of minority carriers produced by adding a small amount of oxygen to the nominal CS2_{2} + CF4_{4} target gas mixture. The CS2_2 + CF4_4 + O2_2 mixture has been shown to enable background-free operation at current sensitivities. Sulfur, fluorine, and carbon recoils were generated using neutrons emitted from a 252^{252}Cf source positioned at different locations around the detector. Measurement of the relative energy loss along the recoil tracks allowed the track vector sense, or the so-called head-tail asymmetry parameter, to be deduced. Results show that the previously reported observation of head-tail sensitivity in pure CS2_{2} is well retained after the addition of oxygen to the gas mixture

    Radon in the DRIFT-II directional dark matter TPC: emanation, detection and mitigation

    Get PDF
    Radon gas emanating from materials is of interest in environmental science and also a major concern in rare event non-accelerator particle physics experiments such as dark matter and double beta decay searches, where it is a major source of background. Notable for dark matter experiments is the production of radon progeny recoils (RPRs), the low energy (~ 100 keV) recoils of radon daughter isotopes, which can mimic the signal expected from WIMP interactions. Presented here are results of measurements of radon emanation from detector materials in the 1 m3 DRIFT-II directional dark matter gas time projection chamber experiment. Construction and operation of a radon emanation facility for this work is described, along with an analysis to continuously monitor DRIFT data for the presence of internal 222Rn and 218Po. Applying this analysis to historical DRIFT data, we show how systematic substitution of detector materials for alternatives, selected by this device for low radon emanation, has resulted in a factor of ~ 10 reduction in internal radon rates. Levels are found to be consistent with the sum from separate radon emanation measurements of the internal materials and also with direct measurement using an attached alpha spectrometer. The current DRIFT detector, DRIFT-IId, is found to have sensitivity to 222Rn of 2.5 μBql−1 with current analysis efficiency, potentially opening up DRIFT technology as a new tool for sensitive radon assay of materials

    Reducing DRIFT backgrounds with a submicron aluminized-mylar cathode

    Get PDF
    Background events in the DRIFT-IId dark matter detector, mimicking potential WIMP signals, are predominantly caused by alpha decays on the central cathode in which the alpha particle is completely or partially absorbed by the cathode material. We installed a View the MathML source thick aluminized-mylar cathode as a way to reduce the probability of producing these backgrounds. We study three generations of cathode (wire, thin-film, and radiologically clean thin-film) with a focus on the ratio of background events to alpha decays. Two independent methods of measuring the absolute alpha decay rate are used to ensure an accurate result, and agree to within 10%. Using alpha range spectroscopy, we measure the radiologically cleanest cathode version to have a contamination of 3.3±0.1 ppt 234U and 73±2 ppb 238U. This cathode reduces the probability of producing an RPR from an alpha decay by a factor of 70±20 compared to the original stainless steel wire cathode. First results are presented from a texturized version of the cathode, intended to be even more transparent to alpha particles. These efforts, along with other background reduction measures, have resulted in a drop in the observed background rate from 500/day to 1/day. With the recent implementation of full-volume fiducialization, these remaining background events are identified, allowing for background-free operation

    Low Threshold Results and Limits from the DRIFT Directional Dark Matter Detector

    Get PDF
    We present results from a 54.7 live-day shielded run of the DRIFT-IId detector, the world's most sensitive, directional, dark matter detector. Several improvements were made relative to our previous work including a lower threshold for detection, a more robust analysis and a tenfold improvement in our gamma rejection factor. After analysis, no events remain in our fiducial region leading to an exclusion curve for spin-dependent WIMP-proton interactions which reaches 0.28 pb at 100 GeV/c^2 a fourfold improvement on our previous work. We also present results from a 45.4 live-day unshielded run of the DRIFT-IId detector during which 14 nuclear recoil-like events were observed. We demonstrate that the observed nuclear recoil rate of 0.31+/-0.08 events per day is consistent with detection of ambient, fast neutrons emanating from the walls of the Boulby Underground Science Facility

    Intercomparison on the measurement of the thoron exhalation rate from building materials.

    No full text
    Thoron (220Rn) exhalation from building materials has become increasingly recognized as a potential source for radiation exposure in dwellings. However, contrary to radon (222Rn), limited information on thoron exposure is available. As a result no harmonized test procedures for determining thoron exhalation from building materials are available at present. This study is a first interlaboratory comparison of different test methods to determine the thoron exhalation and a pre-step to a harmonized standard. The purpose of this study is to compare the experimental findings from a set of three building materials that are tested, and to identify future challenges in the development of a harmonized standard

    Oligodendroglioma in a patient with AIDS: case report and review of the literature Oligodendroglioma en un paciente con sida: reporte de caso y revisión de la literatura

    Get PDF
    In the last years, new techniques of neuroimages and histopathological methods have been added to the management of cerebral mass lesions in patients with AIDS. Stereotactic biopsy is necessary when after 14 days of empirical treatment for Toxoplasma gondii encephalitis there is no clinical or neuroradiologic improvement. We report a woman with AIDS who developed a single focal brain lesion on the right frontal lobe. She presented a long history of headache and seizures. After two weeks of empirical treatment for toxoplasma encephalitis without response, a magnetic resonance image with spectroscopy was performed and showed a tumoral pattern with a choline peak, diminished of N-acetyl-aspartate and presence of lactate. A stereotactic biopsy was performed. Histopathological diagnosis was a diffuse oligodendroglioma type A. A microsurgical resection of the tumor was carried out and antiretroviral treatment was started. To date she is in good clinical condition, with undetectable plasma viral load and CD4 T cell count > 200 cell/uL.<br>En los últimos años, las nuevas técnicas de neuroimágenes y diversos métodos de diagnóstico histopatológico se han agregado al manejo clínico de las lesiones de masa cerebral ocupante en los pacientes con sida. La biopsia estereotáxica es necesaria cuando, luego de dos semanas de tratamiento empírico para toxoplasmosis cerebral, no se comprueba mejoría clínica ni neurorradiológica. Presentamos una paciente con sida que desarrolló una lesión cerebral a nivel del lóbulo frontal derecho. Como antecedente refirió una larga historia de cefalea y convulsiones. La resonancia nuclear magnética con espectroscopia de voxel único ubicado a nivel de la lesión mostró un patrón de lesión tumoral con pico de colina, déficit de N-acetil-aspartato y presencia de ácido láctico. La biopsia estereotáxica y el estudio histopatológico permitieron arribar al diagnóstico de oligodendroglioma difuso de tipo A. Se le efectuó resección por microcirugía y tratamiento antirretroviral de alta eficacia. Actualmente la paciente se encuentra en buen estado clínico, con carga viral indetectable y recuento de linfocitos T CD4 + > de 200 cél/uL
    corecore