18 research outputs found

    Association Between Cardiac Radiation Exposure and the Risk of Arrhythmia in Breast Cancer Patients Treated With Radiotherapy:A Case-Control Study

    Get PDF
    Background: Previous studies suggested that radiation therapy (RT) for breast cancer (BC) can induce cardiac arrhythmias and conduction disorders. However, the association with mean heart dose and specific cardiac substructures doses was less studied. Materials and Methods: We conducted a nested case-control study based on French BC patients, enrolled in the European MEDIRAD-BRACE study (https://clinicaltrials.gov, Identifier: NCT03211442), who underwent three-dimensional conformal radiation therapy (3D-CRT) between 2009 and 2013 and were retrospectively followed until 2019. Cases were incident cases of cardiac arrhythmia. Controls without arrhythmia were selected with propensity-scored matching by age, duration of follow-up, chemotherapy, hypertension, and diabetes (ratio 1:4 or 5). Doses to the whole heart (WH), left and right atria (LA and RA), and left and right ventricles (LV and RV) were obtained after delineation with multi-atlas-based automatic segmentation. Results: The study included 116 patients (21 cases and 95 controls). Mean age at RT was 64 ± 10 years, mean follow-up was 7.0 ± 1.3 years, and mean interval from RT to arrhythmia was 4.3 ± 2.1 years. None of the results on association between arrhythmia and cardiac doses reached statistical significance. However, the proportion of right-sided BC was higher among patients with arrhythmia than among controls (57% vs. 51%, OR = 1.18, p = 0.73). Neither mean WH dose, nor LV, RV, and LA doses were associated with an increased risk of arrhythmia (OR = 1.00, p > 0.90). In contrast, the RA dose was slightly higher for cases compared to controls [interquartile range (0.61-1.46 Gy) vs. (0.49-1.31 Gy), p = 0.44], and a non-significant trend toward a potentially higher risk of arrhythmia with increasing RA dose was observed (OR = 1.19, p = 0.60). Subanalysis according to BC laterality showed that the association with RA dose was reinforced specifically for left-sided BC (OR = 1.76, p = 0.75), while for right-sided BC, the ratio of mean RA/WH doses may better predict arrhythmia (OR = 2.39, p = 0.35). Conclusion: Despite non-significant results, our exploratory investigation on BC patients treated with RT is the first study to suggest that right-sided BC patients and the right atrium irradiation may require special attention regarding the risk of cardiac arrhythmia and conduction disorders. Further studies are needed to expand on this topic

    Subclinical Left Ventricular Dysfunction Detected by Speckle-Tracking Echocardiography in Breast Cancer Patients Treated With Radiation Therapy:A Six-Month Follow-Up Analysis (MEDIRAD EARLY‐HEART study)

    Get PDF
    Copyright © 2022 Locquet, Spoor, Crijns, van der Harst, Eraso, Guedea, Fiuza, Santos, Combs, Borm, Mousseaux, Gencer, Frija, Cardis, Langendijk and Jacob. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.Background: In the case of breast cancer (BC), radiotherapy (RT) helps reduce locoregional recurrence and BC-related deaths but can lead to cardiotoxicity, resulting in an increased risk of long-term major cardiovascular events. It is therefore of primary importance to early detect subclinical left ventricular (LV) dysfunction in BC patients after RT and to determine the dose-response relationships between cardiac doses and these events. Methods: Within the frame of the MEDIRAD European project (2017-2022), the prospective multicenter EARLY-HEART study (ClinicalTrials.gov Identifier: NCT03297346) included chemotherapy naĂŻve BC women aged 40-75 years and treated with lumpectomy and adjuvant RT. Myocardial strain analysis was provided using speckle-tracking echocardiography performed at baseline and 6 months following RT. A global longitudinal strain (GLS) reduction >15% between baseline and follow-up was defined as a GLS-based subclinical LV dysfunction. Individual patient dose distributions were obtained using multi-atlas-based auto-segmentation of the heart. Dose-volume parameters were studied for the whole heart (WH) and left ventricle (LV). Results: The sample included 186 BC women (57.5 ± 7.9 years, 64% left-sided BC). GLS-based subclinical LV dysfunction was observed in 22 patients (14.4%). These patients had significantly higher cardiac exposure regarding WH and LV doses compared to patients without LV dysfunction (for mean WH dose: 2.66 ± 1.75 Gy versus 1.64 ± 0.96 Gy, p = 0.01). A significantly increased risk of subclinical LV dysfunction was observed with the increase in the dose received to the WH [ORs from 1.13 (V5) to 1.74 (Dmean); p <0.01] and to the LV [ORs from 1.10 (V5) to 1.46 (Dmean); p <0.01]. Based on ROC analysis, the LV-V5 parameter may be the best predictor of the short-term onset of subclinical LV dysfunction. Conclusion: These results highlighted that all cardiac doses were strongly associated with the occurrence of subclinical LV dysfunction arising 6 months after BC RT. Whether measurements of GLS at baseline and 6 months after RT combined with cardiac doses can early predict efficiently subclinical events occurring 24 months after RT remains to be investigated.The European Community’s Horizon 2020 Programme supported the EARLY-HEART study conducted in the frame of the MEDIRAD - Implications of Medical Low Dose Radiation Exposure - project spanning from 2017 to 2021 granted by the Euratom Research and Training Programme 2014-2014 under agreement No. 755523.info:eu-repo/semantics/publishedVersio

    Early detection of cardiovascular changes after radiotherapy for breast cancer: protocol for a European multicenter prospective cohort study (MEDIRAD EARLY HEART Study)

    Get PDF
    Background: breast cancer is the most common cancer among women, and radiotherapy plays a major role in its treatment. However, breast cancer radiotherapy can lead to incidental irradiation of the heart, resulting in an increased risk for a variety of heart diseases arising many years after radiotherapy. Therefore, identifying breast cancer patients at the highest risk for radiation-induced cardiac complications is crucial for developing strategies for primary and secondary prevention, which may contribute to healthy aging. There is still a need for precise knowledge on the relationship between radiation dose to specific cardiac structures and early subclinical cardiac changes and their occurrence over time that could finally lead to cardiac complications. Objective: the MEDIRAD EARLY HEART study aims to identify and validate new cardiac imaging and circulating biomarkers of radiation-induced cardiovascular changes arising within first 2 years of breast cancer radiotherapy and to develop risk models integrating these biomarkers combined with precise dose metrics of cardiac structures based on three-dimensional dosimetry. Methods: the EARLY HEART study is a multicenter, prospective cohort study in which 250 women treated for breast cancer and followed for 2 years after radiotherapy will be included. Women treated with radiotherapy without chemotherapy for a unilateral breast cancer and aged 40-75 years meet the inclusion criteria. Baseline and follow-up data include cardiac measurements based on two-dimensional speckle-tracking echocardiography, computed tomography coronary angiography, cardiac magnetic resonance imaging, and a wide panel of circulating biomarkers of cardiac injury. The absorbed dose will be evaluated globally for the heart and different substructures. Furthermore, the dose-response relationship will allow modeling the radiation-induced occurrence and evolution of subclinical cardiac lesions and biomarkers to develop prediction models. Results: this study details the protocol of the MEDIRAD EARLY HEART study and presents the main limits and advantages of this international project. The inclusion of patients began in 2017. Preliminary results are expected to be published in 2019, and complete analysis should be published in 2021. Conclusions: the MEDIRAD EARLY HEART study will allow identifying the main cardiac imaging and blood-based determinants of radiation-induced cardiac injuries to better propose primary and secondary preventive measures in order to contribute to enhanced patient care and quality of life

    Validation of separate multi-atlases for auto segmentation of cardiac substructures in CT-scans acquired in deep inspiration breath hold and free breathing

    Get PDF
    Background and purpose: Developing NTCP-models for cardiac complications after breast cancer (BC) radiotherapy requires cardiac dose-volume parameters for many patients. These can be obtained by using multi-atlas based automatic segmentation (MABAS) of cardiac structures in planning CT scans. We investigated the relevance of separate multi-atlases for deep inspiration breath hold (DIBH) and free breathing (FB) CT scans. Materials and methods: BC patients scanned in DIBH (n = 10) and in FB (n = 20) were selected to create separate multi-atlases consisting of expert panel delineations of the whole heart, atria and ventricles. The accuracy of atlas-generated contours was validated with expert delineations in independent datasets (n = 10 for DIBH and FB) and reported as Dice coefficients, contour distances and dose-volume differences in relation to interobserver variability of manual contours. Dependency of MABAS contouring accuracy on breathing technique was assessed by validation of a FB atlas in DIBH patients and vice versa (cross validation). Results: For all structures the FB and DIBH atlases resulted in Dice coefficients with their respective reference contours > 0.8 and average contour distances < 2 mm smaller than slice thickness of (CTs). No significant differences were found for dose-volume parameters in volumes receiving relevant dose levels (WH, LV and RV). Accuracy of the DIBH atlas was at least similar to, and for the ventricles better than, the interobserver variation in manual delineation. Cross-validation between breathing techniques showed a reduced MABAS performance. Conclusion: Multi-atlas accuracy was at least similar to interobserver delineation variation. Separate atlases for scans made in DIBH and FB could benefit atlas performance because accuracy depends on breathing technique

    [18F]FDG Uptake in Adipose Tissue Is Not Related to Inflammation in Type 2 Diabetes Mellitus

    Get PDF
    PURPOSE: 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) uptake is a marker of metabolic activity and is therefore used to measure the inflammatory state of several tissues. This radionuclide marker is transported through the cell membrane via glucose transport proteins (GLUTs). The aim of this study is to investigate whether insulin resistance (IR) or inflammation plays a role in [18F]FDG uptake in adipose tissue (AT). PROCEDURES: This study consisted of an in vivo clinical part and an ex vivo mechanistic part. In the clinical part, [18F]FDG uptake in abdominal visceral AT (VAT) and subcutaneous AT (SAT) was determined using PET/CT imaging in 44 patients with early type 2 diabetes mellitus (T2DM) (age 63 [54-66] years, HbA1c [6.3 ± 0.4 %], HOMA-IR 5.1[3.1-8.5]). Plasma levels were measured with ELISA. In the mechanistic part, AT biopsies obtained from 8 patients were ex vivo incubated with [18F]FDG followed by autoradiography. Next, a qRT-PCR analysis was performed to determine GLUT and cytokine mRNA expression levels. Immunohistochemistry was performed to determine CD68+ macrophage infiltration and GLUT4 protein expression in AT. RESULTS: In vivo VAT [18F]FDG uptake in patients with T2DM was inversely correlated with HOMA-IR (r = - 0.32, p = 0.034), and positively related to adiponectin plasma levels (r = 0.43, p = 0.003). Ex vivo [18F]FDG uptake in VAT was not related to CD68+ macrophage infiltration, and IL-1ß and IL-6 mRNA expression levels. Ex vivo VAT [18F]FDG uptake was positively related to GLUT4 (r = 0.83, p = 0.042), inversely to GLUT3 (r = - 0.83, p = 0.042) and not related to GLUT1 mRNA expression levels. CONCLUSIONS: In vivo [18F]FDG uptake in VAT from patients with T2DM is positively correlated with adiponectin levels and inversely with IR. Ex vivo [18F]FDG uptake in AT is associated with GLUT4 expression but not with pro-inflammatory markers. The effect of IR should be taken into account when interpreting data of [18F]FDG uptake as a marker for AT inflammation

    Performance Evaluation of a Semi-automated Method for [F-18]FDG Uptake in Abdominal Visceral Adipose Tissue

    Get PDF
    PURPOSE: Severity of abdominal obesity and possibly levels of metabolic activity of abdominal visceral adipose tissue (VAT) are associated with an increased risk for cardiovascular disease (CVD). In this context, the purpose of the current study was to evaluate the reproducibility and repeatability of a semi-automated method for assessment of the metabolic activity of VAT using 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) positron emission tomography (PET)/x-ray computed tomography (CT). PROCEDURES: Ten patients with lung cancer who underwent two baseline whole-body [18F]FDG PET/low-dose (LD) CT scans within 1 week were included. Abdominal VAT was automatically segmented using CT between levels L1-L5. The initial CT-based segmentation was further optimized using PET data with a standardized uptake value (SUV) threshold approach (range 1.0-2.5) and morphological erosion (range 0-5 pixels). The [18F]FDG uptake in SUV that was measured by the automated method was compared with manual analysis. The reproducibility and repeatability were quantified using intraclass correlation coefficients (ICCs). RESULTS: The metabolic assessment of VAT on [18F]FDG PET/LDCT scans expressed as SUVmean, using an automated method showed high inter and intra observer (all ICCs > 0.99) and overall repeatability (ICC = 0.98). The manual method showed reproducible inter observer (all ICCs > 0.92), but less intra observer (ICC = 0.57) and less overall repeatability (ICC = 0.78) compared with the automated method. CONCLUSIONS: Our proposed semi-automated method provided reproducible and repeatable quantitative analysis of [18F]FDG uptake in VAT. We expect this method to aid future research regarding the role of VAT in development of CVD

    Widespread pesticide distribution in the European atmosphere questions their degradability in air

    Get PDF
    Risk assessment of pesticide impacts on remote ecosystems makes use of model-estimated degradation in air. Recent studies suggest these degradation rates to be overestimated, questioning current pesticide regulation. Here, we investigated the concentrations of 76 pesticides in Europe at 29 rural, coastal, mountain, and polar sites during the agricultural application season. Overall, 58 pesticides were observed in the European atmosphere. Low spatial variation of 7 pesticides suggests continental-scale atmospheric dispersal. Based on concentrations in free tropospheric air and at Arctic sites, 22 pesticides were identified to be prone to long-range atmospheric transport, which included 15 substances approved for agricultural use in Europe and 7 banned ones. Comparison between concentrations at remote sites and those found at pesticide source areas suggests long atmospheric lifetimes of atrazine, cyprodinil, spiroxamine, tebuconazole, terbuthylazine, and thiacloprid. In general, our findings suggest that atmospheric transport and persistence of pesticides have been underestimated and that their risk assessment needs to be improved
    corecore