15 research outputs found
Current state of perinatal postmortem magnetic resonance imaging: European Society of Paediatric Radiology questionnaire-based survey and recommendations.
BACKGROUND: Postmortem magnetic resonance imaging (MRI) in perinatal and childhood deaths is increasingly used as a noninvasive adjunct or alternative to autopsy. Imaging protocols vary between centres and consensus guidelines do not exist. OBJECTIVE: Our aim was to develop practical, standardised recommendations for perinatal postmortem MRI. MATERIALS AND METHODS: Recommendations were based on the results of two surveys regarding local postmortem MRI practices sent electronically to all 14 members of the European Society of Paediatric Radiology (ESPR) Postmortem Imaging Task Force and 17 members of the International Society of Forensic Radiology and Imaging Task Force (25 different centres). RESULTS: Overall, 11/14 (78.6%) respondents from different institutions perform postmortem MRI. All of these centres perform postmortem MRI for perinatal and neonatal deaths, but only 6/11 (54.5%) perform imaging in older children. CONCLUSION: We propose a clinical standard for postmortem MRI sequences plus optional sequences for neuroimaging and cardiac anatomy depending on available scanning time and referral indications
Projected WIMP sensitivity of the LUX-ZEPLIN dark matter experiment
LUX-ZEPLIN (LZ) is a next-generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector with an active mass of 7 tonnes, LZ will search primarily for low-energy interactions with weakly interacting massive particles (WIMPs), which are hypothesized to make up the dark matter in our galactic halo. In this paper, the projected WIMP sensitivity of LZ is presented based on the latest background estimates and simulations of the detector. For a 1000 live day run using a 5.6-tonne fiducial mass, LZ is projected to exclude at 90% confidence level spin-independent WIMP-nucleon cross sections above 1.4 × 10-48cm2 for a 40 GeV/c2 mass WIMP.
Additionally, a 5σ discovery potential is projected, reaching cross sections below the exclusion limits of recent experiments. For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of 2.3 × 10−43 cm2 (7.1 × 10−42 cm2) for a 40 GeV/c2
mass WIMP is expected. With underground installation well underway, LZ is on track for commissioning at SURF in 2020
Measurement of the gamma ray background in the Davis Cavern at the Sanford Underground Research Facility
Deep underground environments are ideal for low background searches due to the attenuation of cosmic rays by passage through the earth. However, they are affected by backgrounds from γ-rays emitted by 40K and the 238U and 232Th decay chains in the surrounding rock. The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a liquid xenon TPC located within the Davis campus at the Sanford Underground Research Facility, Lead, South Dakota, at the 4,850-foot level. In order to characterise the cavern background, in-situ γ-ray measurements were taken with a sodium iodide detector in various locations and with lead shielding. The integral count rates (0--3300~keV) varied from 596~Hz to 1355~Hz for unshielded measurements, corresponding to a total flux in the cavern of 1.9±0.4~γ cm−2s−1. The resulting activity in the walls of the cavern can be characterised as 220±60~Bq/kg of 40K, 29±15~Bq/kg of 238U, and 13±3~Bq/kg of 232Th
Current and future funding streams for paediatric postmortem imaging: European Society of Paediatric Radiology survey results.
BACKGROUND: Perinatal and childhood postmortem imaging has been accepted as a noninvasive alternative or adjunct to autopsy. However, the variation in funding models from institution to institution is a major factor prohibiting uniform provision of this service. OBJECTIVE: To describe current funding models employed in European and non-European institutions offering paediatric postmortem imaging services and to discuss the perceived barriers to future postmortem imaging service provision. MATERIALS AND METHODS: A web-based 16-question survey was distributed to members of the European Society of Paediatric Radiology (ESPR) and ESPR postmortem imaging task force over a 6-month period (March-August 2021). Survey questions related to the radiologic and autopsy services being offered and how each was funded within the respondent's institute. RESULTS: Eighteen individual responses were received (13/18, 72.2% from Europe). Only one-third of the institutions (6/18, 33.3%) have fully funded postmortem imaging services, with the remainder receiving partial (6/18, 33.3%) or no funding (5/18, 27.8%). Funding (full or partial) was more commonly available for forensic work (13/18, 72%), particularly where this was nationally provided. Where funding was not provided, the imaging and reporting costs were absorbed by the institute. CONCLUSION: Increased access is required for the expansion of postmortem imaging into routine clinical use. This can only be achieved with formal funding on a national level, potentially through health care commissioning and acknowledgement by health care policy makers and pathology services of the value the service provides following the death of a fetus or child. Funding should include the costs involved in training, equipment, reporting and image acquisition
Cosmogenic production of Ar 37 in the context of the LUX-ZEPLIN experiment
© 2022 authors. Published by the American Physical Society.We estimate the amount of Ar37 produced in natural xenon via cosmic-ray-induced spallation, an inevitable consequence of the transportation and storage of xenon on the Earth's surface. We then calculate the resulting Ar37 concentration in a 10-tonne payload (similar to that of the LUX-ZEPLIN experiment) assuming a representative schedule of xenon purification, storage, and delivery to the underground facility. Using the spallation model by Silberberg and Tsao, the sea-level production rate of Ar37 in natural xenon is estimated to be 0.024 atoms/kg/day. Assuming the xenon is successively purified to remove radioactive contaminants in 1-tonne batches at a rate of 1 tonne/month, the average Ar37 activity after 10 tons are purified and transported underground is 0.058-0.090 μBq/kg, depending on the degree of argon removal during above-ground purification. Such cosmogenic Ar37 will appear as a noticeable background in the early science data, while decaying with a 35-day half-life. This newly noticed production mechanism of Ar37 should be considered when planning for future liquid-xenon-based experiments.11Nsciescopu
Identification of radiopure titanium for the LZ dark matter experiment and future rare event searches
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle interactions with a detector containing a total of 10 tonnes of liquid xenon within a double-vessel cryostat. The large mass and proximity of the cryostat to the active detector volume demand the use of material with extremely low intrinsic radioactivity. We report on the radioassay campaign conducted to identify suitable metals, the determination of factors limiting radiopure production, and the selection of titanium for construction of the LZ cryostat and other detector components. This titanium has been measured with activities of 238Ue < 1.6 mBq/kg, 238Ul < 0.09 mBq/kg, 232The=0.28±0.03 mBq/kg, 232Thl=0.25±0.02 mBq/kg, 40K < 0.54 mBq/kg, and 60Co < 0.02 mBq/kg (68% CL). Such low intrinsic activities, which are some of the lowest ever reported for titanium, enable its use for future dark matter and other rare event searches. Monte Carlo simulations have been performed to assess the expected background contribution from the LZ cryostat with this radioactivity. In 1,000 days of WIMP search exposure of a 5.6-tonne fiducial mass, the cryostat will contribute only a mean background of 0.160 ± 0.001(stat) ± 0.030(sys) counts
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector
A Next-Generation Liquid Xenon Observatory for Dark Matter and Neutrino Physics
The nature of dark matter and properties of neutrinos are among the most pressing issues in contemporary particle physics. The dual-phase xenon time-projection chamber is the leading technology to cover the available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity to many alternative dark matter candidates. These detectors can also study neutrinos through neutrinoless double-beta decay and through a variety of astrophysical sources. A next-generation xenon-based detector will therefore be a true multi-purpose observatory to significantly advance particle physics, nuclear physics, astrophysics, solar physics, and cosmology. This review article presents the science cases for such a detector