113 research outputs found
Reconstruction of longitudinal electrons bunch profiles at FACET, SLAC
Work supported by funding from Universite Paris Sud, program "Attractivite" and by the ANR under contract ANR-12-JS05-0003-01 - http://accelconf.web.cern.ch/AccelConf/IPAC2014/papers/thpme093.pdfInternational audienceThe E-203 collaboration is testing a device on FACET at SLAC to measure the longitudinal profile of electron bunches using Smith-Purcell radiation [1]. At FACET the electron bunches have an energy of 20 GeV and a duration of a few hundred femtoseconds [2]. Smith-Purcell radiation is emitted when a charged particle passes close to the sur- face of a metallic grating. We have studied the stability of the measurement from pulse to pulse and the resolution of the measure depending on the number of gratings used
Development of a quality assurance process for the SoLid experiment
The SoLid experiment has been designed to search for an oscillation pattern induced by a light sterile neutrino state, utilising the BR2 reactor of SCK circle CEN, in Belgium.
The detector leverages a new hybrid technology, utilising two distinct scintillators in a cubic array, creating a highly segmented detector volume. A combination of 5 cm cubic polyvinyltoluene cells, with (LiF)-Li-6:ZnS(Ag) sheets on two faces of each cube, facilitate reconstruction of the neutrino signals. Whilst the high granularity provides a powerful toolset to discriminate backgrounds; by itself the segmentation also represents a challenge in terms of homogeneity and calibration, for a consistent detector response. The search for this light sterile neutrino implies a sensitivity to distortions of around O(10)% in the energy spectrum of reactor (v) over bare. Hence, a very good neutron detection efficiency, light yield and homogeneous detector response are critical for data validation. The minimal requirements for the SoLid physics program are a light yield and a neutron detection efficiency larger than 40 PA/MeV/cube and 50% respectively. In order to guarantee these minimal requirements, the collaboration developed a rigorous quality assurance process for all 12800 cubic cells of the detector. To carry out the quality assurance process, an automated calibration system called CALIPSO was designed and constructed. CALIPSO provides precise, automatic placement of radioactive sources in front of each cube of a given detector plane (16 x 16 cubes). A combination of Na-22, Cf-252 and AmBe gamma and neutron sources were used by CALIPSO during the quality assurance process. Initially, the scanning identified defective components allowing for repair during initial construction of the SoLid detector. Secondly, a full analysis of the calibration data revealed initial estimations for the light yield of over 60 PA/MeV and neutron reconstruction efficiency of 68%, validating the SoLid physics requirements
Sperm death and dumping in Drosophila
Mating with more than one male is the norm for females of many species. In addition to generating competition between the ejaculates of different males, multiple mating may allow females to bias sperm use. In Drosophila melanogaster, the last male to inseminate a female sires approximately 80% of subsequent progeny. Both sperm displacement, where resident sperm are removed from storage by the incoming ejaculate of the copulating male, and sperm incapacitation, where incoming seminal fluids supposedly interfere with resident sperm, have been implicated in this pattern of sperm use. But the idea of incapacitation is problematic because there are no known mechanisms by which an individual could damage rival sperm and not their own. Females also influence the process of sperm use, but exactly how is unclear. Here we show that seminal fluids do not kill rival sperm and that any 'incapacitation' is probably due to sperm ageing during sperm storage. We also show that females release stored sperm from the reproductive tract (sperm dumping) after copulation with a second male and that this requires neither incoming sperm nor seminal fluids. Instead, males may cause stored sperm to be dumped or females may differentially eject sperm from the previous mating
Presentation of the Smith-Purcell Experiment at SOLEIL
TUPC37 - Work supported by seed funding from Université Paris-Sud, program "Attractivité" and by the ANR under contract ANR-12-JS05-0003-01International audienceThe potential of Coherent Smith-Purcell radiation as a longitudinal bunch profile monitor has already been demonstrated and has recently been extended to the sub-picosecond range. As a critical step toward the construction of a single shot bunch profile monitor using Coherent Smith-Purcell radiation it is important to measure very accurately the distribution of such radiation. Optimum background suppression techniques need to be found and relatively cheap detectors suitable for the far infra-red need to be qualified. To performthese tasks a test stand has been installed at the end of the linac of the synchrotron SOLEIL. This test stand and the first results from its commissioning will be presented here
Catalysis in flow: the practical and selective aerobic oxidation of alcohols to aldehydes and ketones
Results of the BiPo-1 prototype for radiopurity measurements for the SuperNEMO double beta decay source foils
The development of BiPo detectors is dedicated to the measurement of
extremely high radiopurity in Tl and Bi for the SuperNEMO
double beta decay source foils. A modular prototype, called BiPo-1, with 0.8
of sensitive surface area, has been running in the Modane Underground
Laboratory since February, 2008. The goal of BiPo-1 is to measure the different
components of the background and in particular the surface radiopurity of the
plastic scintillators that make up the detector. The first phase of data
collection has been dedicated to the measurement of the radiopurity in
Tl. After more than one year of background measurement, a surface
activity of the scintillators of (Tl) 1.5
Bq/m is reported here. Given this level of background, a larger BiPo
detector having 12 m of active surface area, is able to qualify the
radiopurity of the SuperNEMO selenium double beta decay foils with the required
sensitivity of (Tl) 2 Bq/kg (90% C.L.) with a six
month measurement.Comment: 24 pages, submitted to N.I.M.
Continuing Educational Needs and Preferences for Swiss Registered Dietitians: Lessons Learned.
Bern University of Applied Sciences (BFH) in Switzerland offers continuing educational programs for registered dietitians. In order to initialize effective changes to maximize attendance, the promotors and barriers influencing the participation of Swiss registered dietitians to continuing education classes were identified. A survey was conducted from December 2013 to January 2014 and sent to 630 registered members of the Swiss Association of Registered Dietitians (SVDE). The questionnaire was developed on the web-based software Survey Monkey® and included 37 open- and closed-ended questions. Evaluation questions were based on a four-point Likert scale and space for individual comments was ensured. Data analysis included descriptive statistics and chi-squared tests. The final sample included 202 dietitians, the majority being female (96%), between 25 and 54 years old (90%) and 45% worked in clinical settings. Almost 70% had participated in a BFH continuing education course. Respondents were overall very satisfied with parameters including course registration, organisation, content, professional competence of teachers, and practical relevance. Preferred course format were short courses (1-2 days). The lecturer’s limited practical experience, no interest to the subject matter, and no cost coverage by employer were mentioned as the main barriers for attending courses. Based on lessons learned from this evaluation, the following aspects should be considered in order to secure the attractiveness of such programs: Favouring shorter more intensive courses and having them taught by lecturers with a strong practical experience, and hence with more insightful approach. Topics should be established based on the audience’s expectations and needs, possibly through an inquiry among professional societies. In addition, overlapping fields as for example nutritional psychology, gerontology, and transdisciplinary approaches could be further included to broaden the dietitians’ perspectives and encourage a more holistic approach. Finally, the registration process and quality of teaching environment should be seamless, in order to avoid negative influences on the course.
Keywords
Continuing education; Dietetics; Nutritionists; Needs assessmen
Zum Zusammenhang von Geschlechterungleichheiten in Bildung, Beruf und Karriere : ein Ausblick
Ziel der folgenden Ausführungen im abschliessenden Teil dieses Sammelbands zur Entwicklung und Genese von geschlechtsspezifischen Bildungsungleichheiten ist es, den Blick zu öffnen in Richtung Berufsleben. Wie sind die verbesserten Bildungsmöglichkeiten von Frauen zu interpretieren? Ist es in den letzten Jahrzehnten gelungen, eines der grundlegendsten gesellschaftlichen Ungleichheitsverhältnisse zu beseitigen? Oder beginnt sich dieses sogar zu verkehren in eine gesellschaftliche Benachteiligung der Männer? Wir gehen bei unseren Überlegungen von der These aus, dass ein Abbau von Benachteiligungen der Frauen im Bildungssystem für sich genommen noch wenig aussagekräftig ist, wenn wir uns mit der klassischen soziologischen Frage der Persistenz bzw. des Wandels von gesellschaftlichen Ungleichheiten befassen wollen. Erst wenn die ganze Verknüpfung von Bildung und gesellschaftlicher Ungleichheit in den Blick genommen wird und sich dabei zeigt, dass Frauen ihre Bildungsgewinne auch in entsprechende Chancen im Beschäftigungssystem umsetzen können, sind ihre verbesserten Bildungschancen ein Gewinn für die Individuen und ein Fortschritt für die Gesellschaft – und erst dann könnten mögliche Bildungsvorteile von Frauen, wie sie in den vorliegenden Aufsätzen z.T. diagnostiziert werden, gar als neue gesellschaftliche Benachteiligungen von Männern skandalisiert werden
Nutritional genomics A survey to identify knowledge, interest, and continuing education needs among swiss and Portuguese nutritionists and dietitians
SoLid: A short baseline reactor neutrino experiment
The SoLid experiment, short for Search for Oscillations with a Lithium-6 detector, is a new generation neutrino experiment which tries to address the key challenges for high precision reactor neutrino measurements at very short distances from a reactor core and with little or no overburden. The primary goal of the SoLid experiment is to perform a precise measurement of the electron antineutrino energy spectrum and flux and to search for very short distance neutrino oscillations as a probe of eV-scale sterile neutrinos. This paper describes the SoLid detection principle, the mechanical design and the construction of the detector. It then reports on the installation and commissioning on site near the BR2 reactor, Belgium, and finally highlights its performance in terms of detector response and calibration
- …