82 research outputs found

    Analysis of the degradation of amorphous silicon-based modules after 11 years of exposure by means of IEC60891:2021 procedure 3

    Get PDF
    The degradation of two amorphous silicon-based photovoltaic (PV) modules, namely, of single junction amorphous silicon (a-Si) and of micromorph tandem (a-Si/μ-Si), after 11 years of exposure in the south of Spain is analyzed. Their I-V curves were measured outdoors to study the changes of the electrical parameters in the course of three different periods: during the initial days of exposure, during the first year, and in the subsequent 10-year period. The translation of the curves to an identical set of operating conditions, which enables a meaningful comparison, was done by the dif ferent correction procedures described in the standard IEC60891:2021, including the procedure 3, which does not require the knowledge of module parameters, whose values are typically not available. The annual power degradation rates over the entire 11-year period are 1.12% for the a-Si module, which is 3.02% for the first year, and 0.98% for the a-Si/μ-Si, which is 2.29% for the initial yearThis work is supported by Ministero dell'Istruzione, dell'Università e della Ricerca (Italy) (grant PRIN2020-HOTSPHOT 2020LB9TBC and grant PRIN2017-HEROGRIDS 2017WA5ZT3_003); Università degli Studi di Salerno (FARB funds); Ministerio de Ciencia, Innovacion y Universidades (Spain) (grant RTI2018-095097-B-I0)

    Design the efficiency color: Luminescent Solar Concentrators and user acceptance

    Get PDF
    Experiments were carried out with different semitransparent and colorless luminophores, so that passive energy facades of urban buildings capture effective energy through their glass. Inorganic dyes are used with rare earth elements such as Eu3 + and Nd3 + / Yb3 + lanthanide pair, to move solar spectrum towards nir wavelength range, which is the near infrared (nir) spectral region from the end of the highest visible lengths (around 780 nm) up to 3000 nm (13000 cm-1 to 3300 cm-1 ), combined with nanostructured silica particles to increase the luminescent quantum yields and brightness. User acceptance study based on emotions, considers the acceptance degree regarding presence of color in glass. Experimental results demonstrate optical power efficiency, higher with inorganic dyes (2.2%) than lanthanides (1.3%) for samples of crystals with Luminescent Solar Concentrators (csls) of 3.5 x 3.5 cm2 tinted and fully transparent, with optical transmittance ≈ 90%. Question about the presence of color in glass and its relationship with energy efficiency is solved

    Efficient total energy calculations from self-energy models

    Get PDF
    We propose a new method for calculating total energies of systems of interacting electrons, which requires little more computational resources than standard density-functional theories. The total energy is calculated within the framework of many-body perturbation theory by using an efficient model of the self-energy, that nevertheless retains the main features of the exact operator. The method shows promising performance when tested against quantum Monte Carlo results for the linear response of the homogeneous electron gas and structural properties of bulk silicon

    New 3-Dimensional Volumetric Ultrasound Method for Accurate Quantification of Atherosclerotic Plaque Volume.

    Get PDF
    Carotid and femoral plaque burden is a recognized biomarker of cardiovascular disease risk. A new electronic-sweep 3-dimensional (3D)-matrix transducer method can improve the functionality and image quality of vascular ultrasound atherosclerosis imaging. This study aimed to validate this method for plaque volume measurement in early and intermediate-advanced plaques in the carotid and femoral territories. Plaque volumes were measured ex vivo in pig carotid and femoral artery specimens by 3-dimensional vascular ultrasound (3DVUS) using a 3D-matrix (electronic-sweep) transducer and its associated 3D plaque quantification software, and were compared with gold-standard histology. To test the clinical feasibility and accuracy of the 3D-matrix transducer, an experiment was conducted in intermediate-high risk individuals with carotid and femoral atherosclerosis. The results were compared with those obtained using the previously validated mechanical-sweep 3D transducer and established 2-dimensional (2D)-based plaque quantification software. In the ex vivo study, the authors assessed 19 atherosclerotic plaques (plaque volume, 0.76 µL-56.30 μL), finding strong agreement between measurements with the 3D-matrix transducer and the histological gold-standard (intraclass correlation coefficient [ICC]: 0.992; [95% CI: 0.978-0.997]). In the clinical analysis of 20 patients (mean age 74.6 ± 4.45 years; 40% men), the authors found 64 (36 carotid and 28 femoral) of 80 scanned territories with atherosclerosis (measured atherosclerotic volume, 10 μL-859 μL). There was strong agreement between measurements made from electronic-sweep and mechanical-sweep 3DVUS transducers (ICC: 0.997 [95% CI: 0.995-0.998]). Agreement was also high between plaque volumes estimated by the 2D and 3D plaque quantification software applications (ICC: 0.999 [95% CI: 0.998-0.999]). Analysis time was significantly shorter with the 3D plaque quantification software than with the 2D multislice approach with a mean time reduction of 46%. 3DVUS using new matrix transducer technology, together with improved 3D plaque quantification software, simplifies the accurate volume measurement of early (small) and intermediate-advanced plaques located in carotid and femoral arteries.This study was partially funded by grants from the Ministerio de Economia, Industria y Competividad (MEIC) with cofunding from the European Regional Development Fund (ERDF) (SAF2016-75580-R to Dr Bentzon) and (BES-2016-076633 to Dr Nogales). Research funding was also received from the Instituto de Salud Carlos III Spain (PIE16/ 00021 to Drs Bueno and Fuster). The CNIC is supported by the Min- isterio de Ciencia, Innovacion y Universidades (MICINN) and the Pro CNIC Foundation and is a Severo Ochoa Center of Excellence (CEX2020-001041-S). This study forms part of a Master Research Agreement between the CNIC and Philips Healthcare. Drs Sánchez- González, Entrekin, and Collet-Billon are employees of Philips Healthcare. All other authors have reported that they have no re- lationships to disclose related to the contents of this paper.S

    Diagrammatic self-energy approximations and the total particle number

    Get PDF
    There is increasing interest in many-body perturbation theory as a practical tool for the calculation of ground-state properties. As a consequence, unambiguous sum rules such as the conservation of particle number under the influence of the Coulomb interaction have acquired an importance that did not exist for calculations of excited-state properties. In this paper we obtain a rigorous, simple relation whose fulfilment guarantees particle-number conservation in a given diagrammatic self-energy approximation. Hedin's G(0)W(0) approximation does not satisfy this relation and hence violates the particle-number sum rule. Very precise calculations for the homogeneous electron gas and a model inhomogeneous electron system allow the extent of the nonconservation to be estimated

    Measurement, modeling and simulation of photovoltaic degradation rates

    Get PDF
    Photovoltaic degradation rates play a vital role in visualizing and analyzing the performance of the PV modules over the long run. A site survey is conducted to calculate PV degradation rates. The results have shown that for the first three years since the initial installation, the degradation rates have remained in line with the manufacturer values (i.e., less than 0.6%), while the next two years the degradation rates have almost increased by 40%. This is due to discoloration of the encapsulant causing the reduction of the short circuit current (Isc). Mathematically, modeling such visual loss factors has not considered so far. The visual loss factor equation is developed and incorporated in the output current equation of the PV module. Further, the I-V curves are simulated and compared with the measured I-V curves. The results have shown an acceptable error percentage of around 0.3%

    Noninvasive monitoring of serial changes in pulmonary vascular resistance and acute vasodilator testing using cardiac magnetic resonance

    Get PDF
    Objectives The study sought to evaluate the ability of cardiac magnetic resonance (CMR) to monitor acute and long-term changes in pulmonary vascular resistance (PVR) noninvasively. Background PVR monitoring during the follow-up of patients with pulmonary hypertension (PH) and the response to vasodilator testing require invasive right heart catheterization. Methods An experimental study in pigs was designed to evaluate the ability of CMR to monitor: 1) an acute increase in PVR generated by acute pulmonary embolization (n = 10); 2) serial changes in PVR in chronic PH (n = 22); and 3) changes in PVR during vasodilator testing in chronic PH (n = 10). CMR studies were performed with simultaneous hemodynamic assessment using a CMR-compatible Swan-Ganz catheter. Average flow velocity in the main pulmonary artery (PA) was quantified with phase contrast imaging. Pearson correlation and mixed model analysis were used to correlate changes in PVR with changes in CMR-quantified PA velocity. Additionally, PVR was estimated from CMR data (PA velocity and right ventricular ejection fraction) using a formula previously validated. Results Changes in PA velocity strongly and inversely correlated with acute increases in PVR induced by pulmonary embolization (r = –0.92), serial PVR fluctuations in chronic PH (r = –0.89), and acute reductions during vasodilator testing (r = –0.89, p ≤ 0.01 for all). CMR-estimated PVR showed adequate agreement with invasive PVR (mean bias –1.1 Wood units,; 95% confidence interval: –5.9 to 3.7) and changes in both indices correlated strongly (r = 0.86, p < 0.01). Conclusions CMR allows for noninvasive monitoring of acute and chronic changes in PVR in PH. This capability may be valuable in the evaluation and follow-up of patients with PH

    Intracoronary administration of allogeneic adipose tissue-derived mesenchymal stem cells improves myocardial perfusion but not left ventricle function, in a translational model of acute myocardial infarction

    Get PDF
    Background-¿Autologous adipose tissue-derived mesenchymal stem cells (ATMSCs) therapy is a promising strategy to improve post-myocardial infarction outcomes. In a porcine model of acute myocardial infarction, we studied the long-term effects and the mechanisms involved in allogeneic ATMSCs administration on myocardial performance. Methods and Results-¿Thirty-eight pigs underwent 50 minutes of coronary occlusion; the study was completed in 33 pigs. After reperfusion, allogeneic ATMSCs or culture medium (vehicle) were intracoronarily administered. Follow-ups were performed at short (2 days after acute myocardial infarction vehicle-treated, n=10; ATMSCs-treated, n=9) or long term (60 days after acute myocardial infarction vehicle-treated, n=7; ATMSCs-treated, n=7). At short term, infarcted myocardium analysis showed reduced apoptosis in the ATMSCs-treated animals (48.6 6% versus 55.9 5.7% in vehicle; P=0.017); enhancement of the reparative process with up-regulated vascular endothelial growth factor, granulocyte macrophage colony-stimulating factor, and stromal-derived factor-1a gene expression; and increased M2 macrophages (67.2 10% versus 54.7 10.2% in vehicle; P=0.016). In long-term groups, increase in myocardial perfusion at the anterior infarct border was observed both on day-7 and day-60 cardiac magnetic resonance studies in ATMSCs-treated animals, compared to vehicle (87.9 28.7 versus 57.4 17.7 mL/min per gram at 7 days; P=0.034 and 99 22.6 versus 43.3 14.7 22.6 mL/min per gram at 60 days; P=0.0001, respectively). At day 60, higher vascular density was detected at the border zone in the ATMSCs-treated animals (118 18 versus 92.4 24.3 vessels/mm2 in vehicle; P=0.045). Cardiac magnetic resonance-measured left ventricular ejection fraction of left ventricular volumes was not different between groups at any time point. Conclusions-¿In this porcine acute myocardial infarction model, allogeneic ATMSCs-based therapy was associated with increased cardioprotective and reparative mechanisms and with better cardiac magnetic resonance-measured perfusion. No effect on left ventricular volumes or ejection fraction was observed
    corecore