1,238 research outputs found

    Software Provisioning of the Protech Integrated Engineering Automation System

    Get PDF
    This is a presentation of the basic principle, operational functions and modules of the software for planning, programming and control of the serial production in the engineering automation system environment. We specified the software provisioning of the particular application and the benefits from its use in the manufacture process. There is a description of the available data bases for the input of the basic technological information about the work-pieces and details and for setting-up of the metal-processing tools. This product traces the technological sequence and the specifics of the production process of machines with computer and numerical control (CNC), the direct connection and dependency of the individual modules within the processing and exchange of the running current information

    Induction of PNAd and N-acetylglucosamine 6-O-sulfotransferases 1 and 2 in mouse collagen-induced arthritis

    Get PDF
    BACKGROUND: Leukocyte recruitment across blood vessels is fundamental to immune surveillance and inflammation. Lymphocyte homing to peripheral lymph nodes is mediated by the adhesion molecule, L-selectin, which binds to sulfated carbohydrate ligands on high endothelial venules (HEV). These glycoprotein ligands are collectively known as peripheral node addressin (PNAd), as defined by the function-blocking monoclonal antibody known as MECA-79. The sulfation of these ligands depends on the action of two HEV-expressed N-acetylglucosamine 6-O-sulfotransferases: GlcNAc6ST-2 and to a lesser degree GlcNAc6ST-1. Induction of PNAd has also been shown to occur in a number of human inflammatory diseases including rheumatoid arthritis (RA). RESULTS: In order to identify an animal model suitable for investigating the role of PNAd in chronic inflammation, we examined the expression of PNAd as well as GlcNAc6ST-1 and -2 in collagen-induced arthritis in mice. Here we show that PNAd is expressed in the vasculature of arthritic synovium in mice immunized with collagen but not in the normal synovium of control animals. This de novo expression of PNAd correlates strongly with induction of transcripts for both GlcNAc6ST-1 and GlcNAc6ST-2, as well as the expression of GlcNAc6ST-2 protein. CONCLUSION: Our results demonstrate that PNAd and the sulfotransferases GlcNAc6ST-1 and 2 are induced in mouse collagen-induced arthritis and suggest that PNAd antagonists or inhibitors of the enzymes may have therapeutic benefit in this widely-used mouse model of RA

    Sulfation of a High Endothelial Venule–Expressed Ligand for L-Selectin: Effects on Tethering and Rolling of Lymphocytes

    Get PDF
    During lymphocyte homing, L-selectin mediates the tethering and rolling of lymphocytes on high endothelial venules (HEVs) in secondary lymphoid organs. The L-selectin ligands on HEV are a set of mucin-like glycoproteins, for which glycosylation-dependent cell adhesion molecule 1 (GlyCAM-1) is a candidate. Optimal binding in equilibrium measurements requires sulfation, sialylation, and fucosylation of ligands. Analysis of GlyCAM-1 has revealed two sulfation modifications (galactose [Gal]-6-sulfate and N-acetylglucosamine [GlcNAc]-6-sulfate) of sialyl Lewis x. Recently, three related sulfotransferases (keratan sulfate galactose-6-sulfotransferase [KSGal6ST], high endothelial cell N-acetylglucosamine-6-sulfotransferase [GlcNAc6ST], and human GlcNAc6ST) were cloned, which can generate Gal-6-sulfate and GlcNAc-6-sulfate in GlyCAM-1. Imparting these modifications to GlyCAM-1, together with appropriate fucosylation, yields enhanced rolling ligands for both peripheral blood lymphocytes and Jurkat cells in flow chamber assays as compared with those generated with exogenous fucosyltransferase. Either sulfation modification results in an increased number of tethered and rolling lymphocytes, a reduction in overall rolling velocity associated with more frequent pausing of the cells, and an enhanced resistance of rolling cells to detachment by shear. All of these effects are predicted to promote the overall efficiency of lymphocyte homing. In contrast, the rolling interactions of E-selectin transfectants with the same ligands are not affected by sulfation

    Ideally embedded space-times

    Full text link
    Due to the growing interest in embeddings of space-time in higher-dimensional spaces we consider a specific type of embedding. After proving an inequality between intrinsically defined curvature invariants and the squared mean curvature, we extend the notion of ideal embeddings from Riemannian geometry to the indefinite case. Ideal embeddings are such that the embedded manifold receives the least amount of tension from the surrounding space. Then it is shown that the de Sitter spaces, a Robertson-Walker space-time and some anisotropic perfect fluid metrics can be ideally embedded in a five-dimensional pseudo-Euclidean space.Comment: layout changed and typos corrected; uses revtex

    Stress echocardiography for left ventricular diastolic dysfunction detection in patients with non-severe chronic obstructive pulmonary disease: a cross-sectional study

    Get PDF
    Aim To assess whether the simultaneous performance of exercise stress echocardiography and cardio-pulmonary testing (ESE-CPET) may facilitate the timely diagnosis of subclinical left ventricular diastolic dysfunction (LVDD) in patients with non-severe chronic obstructive pulmonary disease (COPD), preserved left ventricular systolic function, and exertional dyspnea or exercise intolerance. Methods This cross-sectional study, conducted between May 2017 and April 2018, involved 104 non-severe COPD patients with exertional dyspnea and preserved ejection fraction who underwent echocardiography before CPET and 1-2 minutes after peak exercise. Based on the peak E/e’ ratio, patients were divided into the group with stressinduced LVDD – E/e’>15 and the group without stress-induced LVDD. We assessed the association between LVDD and the following CPET variables: minute ventilation, peak oxygen uptake (VO2), ventilatory efficiency, heart rate reserve, and blood pressure.Results During ESE-CPET, stress-induced LVDD occurred in 67/104 patients (64%). These patients had lower work load, peak VO2, O2 pulse, and minute ventilation (VE), and higher VE/VCO2 slope than patients without stress-induced LVDD (35.18 ± 10.4 vs 37.01 ± 11.11, P < 0.05). None of the CPET variables correlated with E/e’. Conclusion Combined ESE-CPET may distinguish masked LVDD in patients with non-severe COPD with exertional dyspnea and preserved left ventricular systolic function. None of the CPET variables was a predictor for subclinical LVDD

    Technical Note: 4D cone-beam CT reconstruction from sparse-view CBCT data for daily motion assessment in pencil beam scanned proton therapy (PBS-PT)

    Get PDF
    Purpose: The number of pencil beam scanned proton therapy (PBS-PT) facilities equipped with cone-beam computed tomography (CBCT) imaging treating thoracic indications is constantly rising. To enable daily internal motion monitoring during PBS-PT treatments of thoracic tumors, we assess the performance of Motion-Aware RecOnstructiOn method using Spatial and Temporal Regularization (MA-ROOSTER) four-dimensional CBCT (4DCBCT) reconstruction for sparse-view CBCT data and a realistic data set of patients treated with proton therapy. Methods: Daily CBCT projection data for nine non-small cell lung cancer (NSCLC) patients and one SCLC patient were acquired at a proton gantry system (IBA Proteus® One). Four-dimensional CBCT images were reconstructed applying the MA-ROOSTER and the conventional phase-correlated Feldkamp-Davis-Kress (PC-FDK) method. Image quality was assessed by visual inspection, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and the structural similarity index measure (SSIM). Furthermore, gross tumor volume (GTV) centroid motion amplitudes were evaluated. Results: Image quality for the 4DCBCT reconstructions using MA-ROOSTER was superior to the PC-FDK reconstructions and close to FDK images (median CNR: 1.23 [PC-FDK], 1.98 [MA-ROOSTER], and 1.98 [FDK]; median SNR: 2.56 [PC-FDK], 4.76 [MA-ROOSTER], and 5.02 [FDK]; median SSIM: 0.18 [PC-FDK vs FDK], 0.31 [MA-ROOSTER vs FDK]). The improved image quality of MA-ROOSTER facilitated GTV contour warping and realistic motion monitoring for most of the reconstructions. Conclusion: MA-ROOSTER based 4DCBCTs performed well in terms of image quality and appear to be promising for daily internal motion monitoring in PBS-PT treatments of (N)SCLC patients

    Imaging in population science: cardiovascular magnetic resonance in 100,000 participants of UK Biobank - rationale, challenges and approaches

    Get PDF
    PMCID: PMC3668194SEP was directly funded by the National Institute for Health Research Cardiovascular Biomedical Research Unit at Barts. SN acknowledges support from the Oxford NIHR Biomedical Research Centre and from the Oxford British Heart Foundation Centre of Research Excellence. SP and PL are funded by a BHF Senior Clinical Research fellowship. RC is supported by a BHF Research Chair and acknowledges the support of the Oxford BHF Centre for Research Excellence and the MRC and Wellcome Trust. PMM gratefully acknowledges training fellowships supporting his laboratory from the Wellcome Trust, GlaxoSmithKline and the Medical Research Council

    Evaluation of Clinical and Immunological Markers for predicting Virological Failure in a HIV/AIDS treatment cohort in Busia, Kenya

    Get PDF
    In resource-limited settings where viral load (VL) monitoring is scarce or unavailable, clinicians must use immunological and clinical criteria to define HIV virological treatment failure. This study examined the performance of World Health Organization (WHO) clinical and immunological failure criteria in predicting virological failure in HIV patients receiving antiretroviral therapy (ART)

    High-resolution ab initio three-dimensional X-ray diffraction microscopy

    Full text link
    Coherent X-ray diffraction microscopy is a method of imaging non-periodic isolated objects at resolutions only limited, in principle, by the largest scattering angles recorded. We demonstrate X-ray diffraction imaging with high resolution in all three dimensions, as determined by a quantitative analysis of the reconstructed volume images. These images are retrieved from the 3D diffraction data using no a priori knowledge about the shape or composition of the object, which has never before been demonstrated on a non-periodic object. We also construct 2D images of thick objects with infinite depth of focus (without loss of transverse spatial resolution). These methods can be used to image biological and materials science samples at high resolution using X-ray undulator radiation, and establishes the techniques to be used in atomic-resolution ultrafast imaging at X-ray free-electron laser sources.Comment: 22 pages, 11 figures, submitte

    FLASH free-electron laser single-shot temporal diagnostic: terahertz-field-driven streaking

    Get PDF
    We report on the commissioning of a terahertz (THz) field driven streak camera installed at the free-electron laser FLASH at DESY in Hamburg, being able to deliver the photon pulse duration as well as the arrival time information with around 10 fs resolution for each single XUV FEL pulse. Pulse durations between 300 fs and <15 fs have been measured for different FLASH FEL settings. A comparison between the XUV pulse arrival time and the FEL electron bunch arrival time measured at the FLASH linac section - exhibit a correlation width of 20 fs rms, thus demonstrating the excellent operation stability of FLASH. In addition, the THz streaking setup was operated simultaneously to an alternative method to determine the FEL pulse duration based on spectral analysis. FLASH pulse duration, derived from simple spectral analysis, are in good agreement with that from THz streaking measurement
    • …
    corecore