115 research outputs found

    Self-reported cold sensitivity in normal subjects and in patients with traumatic hand injuries or hand-arm vibration syndrome

    Get PDF
    Background: Cold sensitivity is a common and disabling complaint following hand injuries. The main purpose of this study was to describe self-reported consequences of cold sensitivity and the association with disability and health-related quality of life in patients with hand injuries or hand-arm vibration syndrome (HAVS) and in normal subjects. Methods: Responses to the Cold Intolerance Symptom Severity (CISS) questionnaire, Potential Work Exposure Scale (PWES), Disability of the Arm, Shoulder and Hand (DASH) and Short-Form 36 questionnaire (SF-36) were investigated in normal subjects (n = 94), hand injured patients (amputation and nerve injuries, n = 88) and patients with HAVS (n = 30). The results are presented as median (range), percent and mean deviation from norms. The Kruskal Wallis Test or Mann-Whitney U-Test were used to identify significant differences between multiple groups or subgroups. The Spearman rank correlation was used to study the relationship between cold sensitivity and disability. Results: Abnormal cold sensitivity (CISS score > 50) was seen in 75% and 45% of patients with HAVS and a traumatic hand injury, respectively. Patients were significantly more exposed to cold in their work environment than the normal population, with a consequently negative effect on work ability due to cold sensitivity. Patients with abnormal cold sensitivity were more seriously disabled and had a poorer health-related quality of life than patients with normal cold sensitivity [higher DASH scores and e. g. significantly larger mean deviation from norms in the subscales Role Physical and Bodily Pain (SF-36)]. Conclusion: Severe and abnormal cold sensitivity may have a profound impact on work capacity, leisure, disability and health-related quality of life. It is frequently seen in patients with traumatic hand injuries and particularly apparent in patients with HAVS

    Design and technical construction of a tactile display for sensory feedback in a hand prosthesis system

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The users of today's commercial prosthetic hands are not given any conscious sensory feedback. To overcome this deficiency in prosthetic hands we have recently proposed a sensory feedback system utilising a "tactile display" on the remaining amputation residual limb acting as man-machine interface. Our system uses the recorded pressure in a hand prosthesis and feeds back this pressure onto the forearm skin. Here we describe the design and technical solution of the sensory feedback system aimed at hand prostheses for trans-radial/humeral amputees. Critical parameters for the sensory feedback system were investigated.</p> <p>Methods</p> <p>A sensory feedback system consisting of five actuators, control electronics and a test application running on a computer has been designed and built. Firstly, we investigate which force levels were applied to the forearm skin of the user while operating the sensory feedback system. Secondly, we study if the proposed system could be used together with a myoelectric control system. The displacement of the skin caused by the sensory feedback system would generate artefacts in the recorded myoelectric signals. Accordingly, EMG recordings were performed and an analysis of the these are included. The sensory feedback system was also preliminarily evaluated in a laboratory setting on two healthy non-amputated test subjects with a computer generating the stimuli, with regards to spatial resolution and force discrimination.</p> <p>Results</p> <p>We showed that the sensory feedback system generated approximately proportional force to the angle of control. The system can be used together with a myoelectric system as the artefacts, generated by the actuators, were easily removed using a simple filter. Furthermore, the application of the system on two test subjects showed that they were able to discriminate tactile sensation with regards to spatial resolution and level of force.</p> <p>Conclusions</p> <p>The results of these initial experiments in non-amputees indicate that the proposed tactile display, in its simple form, can be used to relocate tactile input from an artificial hand to the forearm and that the system can coexist with a myoelectric control systems. The proposed system may be a valuable addition to users of myoelectric prosthesis providing conscious sensory feedback during manipulation of objects.</p

    Patients´ Experiences of Pain Following Day Surgery - At 48 Hours, Seven Days and Three Months

    Get PDF
    Recent studies indicate that patients experience pain after day surgery for a longer period than previously known. This requires verification. This was a prospective, descriptive correlational study. A convenience sample of 298 day surgery patients undergoing various surgical procedures was asked to report pain intensity and its interference with daily function 48 hours, seven days and three months after day surgery. Correlation and regression analyses were performed. On a NRS, 55% (n=230) reported pain (≥4) 48 hours after surgery, as did 43% (n=213) at seven days. Pain interfered with normal activities at ≥4 NRS at 48 hours and at seven days, after which it decreased

    Fingersomatotopy in area 3b: an fMRI-study

    Get PDF
    BACKGROUND: The primary sensory cortex (S1) in the postcentral gyrus is comprised of four areas that each contain a body map, where the representation of the hand is located with the thumb most laterally, anteriorly and inferiorly and the little finger most medially, posteriorly and superiorly. Previous studies on somatotopy using functional MRI have either used low field strength, have included a small number of subjects or failed to attribute activations to any area within S1. In the present study we included twenty subjects, who were investigated at 3 Tesla (T). We focused specifically on Brodmann area 3b, which neurons have discrete receptive fields with a potentially more clearcut somatotopic organisation. The spatial distribution for all fingers' peak activation was determined and group as well as individual analysis was performed. RESULTS: Activation maps from 18 subjects were of adequate quality; in 17 subjects activations were present for all fingers and these data were further analysed. In the group analysis the thumb was located most laterally, anteriorly and inferiorly with the other fingers sequentially positioned more medially, posteriorly and superiorly. At the individual level this somatotopic relationship was present for the thumb and little finger, with a higher variability for the fingers in between. The Euclidian distance between the first and fifth finger was 17.2 mm, between the first and second finger 10.6 mm and between the remaining fingers on average 6.3 mm. CONCLUSION: Results from the group analysis, that is both the location of the fingers and the Euclidian distances, are well comparable to results from previous studies using a wide range of modalities. On the subject level the spatial localisation of the fingers showed a less stringent somatotopic order so that the location of a finger in a single subject cannot be predicted from the group result

    Oral health-related quality of life in 4-16-year-olds with and without juvenile idiopathic arthritis

    Get PDF
    Background: Few studies have investigated oral health-related quality of life (OHRQoL) in young individuals with juvenile idiopathic arthritis (JIA). Aims were to investigate whether OHRQoL differs between children and adolescents with JIA compared to controls without JIA, while adjusting for socio-demographic-, behavioral- and oral health-related covariates. Furthermore, to explore whether socio-behavioral and oral health-related covariates of OHRQoL vary according to group affiliation and finally, specifically for individuals with JIA, to investigate whether disease-specific features associate with OHRQoL. We hypothesized that participants with JIA have poorer OHRQoL compared to participants without JIA. Methods: In this comparative cross-sectional study participants with JIA (n = 224) were matched to controls without JIA (n = 224). OHRQoL was assessed according to Early Childhood Oral Health Impact Scale (ECOHIS) (4–11-years-olds) and the child version of Oral Impacts on Daily Performances (Child-OIDP) (12–16-years-olds). JIA-specific characteristics were assessed by pediatric rheumatologists and socio-demographic, behavioral and self-reported oral health information collected by questionnaires. Index teeth were examined for caries by calibrated dentists. Multiple variable analyses were performed using logistic regression, reporting odds ratio (OR) and 95% confidence interval (CI). Two-way interactions were tested between group affiliation and the socio-behavioral- and oral health-related variables on the respective outcome variables. Results: In total, 96 participants with JIA and 98 controls were evaluated according to ECOHIS, corresponding numbers for Child-OIDP was 125 and 124. Group affiliation was not associated with impaired ECOHIS or Child-OIDP in adjusted analyses (OR = 1.95, 95% CI 0.94–4.04 and OR = 0.99, 95% CI 0.46–2.17, respectively). Female adolescents with JIA were more likely than males to report oral impacts according to Child-OIDP. Continued activity or flare was found to adversely affect Child-OIDP, also self-reported outcome measures in JIA associated with Child-OIDP. Conclusions: This study did not provide consistent evidence to confirm the hypothesis that children and adolescents with JIA are more likely to have impaired OHRQoL compared to their peers without JIA. However, female adolescents with JIA were more likely than males to report impacts on OHRQoL. Furthermore, within the JIA group, adolescents with continued disease activity, flare or reporting pain, physical disability, had higher risk than their counterparts of impaired OHRQoL.publishedVersio

    Functional loss of IKBE leads to NF-KB deregulation in aggressive chronic lymphocytic leukemia

    Get PDF
    NF-?B is constitutively activated in chronic lymphocytic leukemia (CLL); however, the implicated molecular mechanisms remain largely unknown. Thus, we performed targeted deep sequencing of 18 core complex genes within the NF-?B pathway in a discovery and validation CLL cohort totaling 315 cases. The most frequently mutated gene was NFKBIE (21/315 cases; 7%), which encodes I?B?, a negative regulator of NF-?B in normal B cells. Strikingly, 13 of these cases carried an identical 4-bp frameshift deletion, resulting in a truncated protein. Screening of an additional 377 CLL cases revealed that NFKBIE aberrations predominated in poor-prognostic patients and were associated with inferior outcome. Minor subclones and/or clonal evolution were also observed, thus potentially linking this recurrent event to disease progression. Compared with wild-type patients, NFKBIE-deleted cases showed reduced I?B? protein levels and decreased p65 inhibition, along with increased phosphorylation and nuclear translocation of p65. Considering the central role of B cell receptor (BcR) signaling in CLL pathobiology, it is notable that I?B? loss was enriched in aggressive cases with distinctive stereotyped BcR, likely contributing to their poor prognosis, and leading to an altered response to BcR inhibitors. Because NFKBIE deletions were observed in several other B cell lymphomas, our findings suggest a novel common mechanism of NF-?B deregulation during lymphomagenesis. <br/

    Photostability of commercial sunscreens upon sun exposure and irradiation by ultraviolet lamps

    Get PDF
    BACKGROUND: Sunscreens are being widely used to reduce exposure to harmful ultraviolet (UV) radiation. The fact that some sunscreens are photounstable has been known for many years. Since the UV-absorbing ingredients of sunscreens may be photounstable, especially in the long wavelength region, it is of great interest to determine their degradation during exposure to UV radiation. Our aim was to investigate the photostability of seven commercial sunscreen products after natural UV exposure (UVnat) and artificial UV exposure (UVart). METHODS: Seven commercial sunscreens were studied with absorption spectroscopy. Sunscreen product, 0.5 mg/cm(2), was placed between plates of silica. The area under the curve (AUC) in the spectrum was calculated for UVA (320–400 nm), UVA1 (340–400 nm), UVA2 (320–340 nm) and UVB (290–320 nm) before (AUC(before)) and after (AUC(after)) UVart (980 kJ/m(2 )UVA and 12 kJ/m(2 )of UVB) and before and after UVnat. If theAUC Index (AUCI), defined as AUCI = AUC(after)/AUC(before), was > 0.80, the sunscreen was considered photostable. RESULTS: Three sunscreens were unstable after 90 min of UVnat; in the UVA range the AUCI was between 0.41 and 0.76. In the UVB range one of these sunscreens was unstable with an AUCI of 0.75 after 90 min. Three sunscreens were photostable after 120 min of UVnat; in the UVA range the AUCI was between 0.85 and 0.99 and in the UVB range between 0.92 and 1.0. One sunscreen showed in the UVA range an AUCI of 0.87 after UVnat but an AUCI of 0.72 after UVart. Five of the sunscreens were stable in the UVB region. CONCLUSION: The present study shows that several sunscreens are photounstable in the UVA range after UVnat and UVart. There is a need for a standardized method to measure photostability, and the photostability should be marked on the sunscreen product
    • …
    corecore