948 research outputs found

    Operational alignment and calibration of the ISU for phase 2 of the V/STOL program. Volume 2 - Alignment

    Get PDF
    Strapdown inertia system for V/STOL program with theoretical error analysis using Kalman filter estimation theory and computer simulatio

    An evaluation of seasonal variations in footwear worn by adults with inflammatory arthritis: a cross-sectional observational study using a web-based survey

    Get PDF
    Background: Foot problems are common in adults with inflammatory arthritis and therapeutic footwear can be effective in managing arthritic foot problems. Accessing appropriate footwear has been identified as a major barrier, resulting in poor adherence to treatment plans involving footwear. Indeed, previous New Zealand based studies found that many people with rheumatoid arthritis and gout wore inappropriate footwear. However, these studies were conducted in a single teaching hospital during the New Zealand summer therefore the findings may not be representative of footwear styles worn elsewhere in New Zealand, or reflect the potential influence of seasonal climate changes. The aim of the study was to evaluate seasonal variations in footwear habits of people with inflammatory arthritic conditions in New Zealand. Methods: A cross-sectional study design using a web-based survey. The survey questions were designed to elicit demographic and clinical information, features of importance when choosing footwear and seasonal footwear habits, including questions related to the provision of therapeutic footwear/orthoses and footwear experiences. Results: One-hundred and ninety-seven participants responded who were predominantly women of European descent, aged between 46–65 years old, from the North Island of New Zealand. The majority of participants identified with having either rheumatoid arthritis (35%) and/or osteoarthritis (57%) and 68% reported established disease (>5 years duration). 18% of participants had been issued with therapeutic footwear. Walking and athletic shoes were the most frequently reported footwear type worn regardless of the time of year. In the summer, 42% reported wearing sandals most often. Comfort, fit and support were reported most frequently as the footwear features of greatest importance. Many participants reported difficulties with footwear (63%), getting hot feet in the summer (63%) and the need for a sandal which could accommodate a supportive insole (73%). Conclusions: Athletic and walking shoes were the most popular style of footwear reported regardless of seasonal variation. During the summer season people with inflammatory arthritis may wear sandals more frequently in order to accommodate disease-related foot deformity. Healthcare professionals and researchers should consider seasonal variation when recommending appropriate footwear, or conducting footwear studies in people with inflammatory arthritis, to reduce non-adherence to prescribed footwear

    The p80 homology region of TEP1 is sufficient for its association with the telomerase and vault RNAs, and the vault particle

    Get PDF
    TEP1 is a protein component of two ribonucleoprotein complexes: vaults and telomerase. The vault-associated small RNA, termed vault RNA (VR), is dependent upon TEP1 for its stable association with vaults, while the association of telomerase RNA with the telomerase complex is independent of TEP1. Both of these small RNAs have been shown to interact with amino acids 1–871 of TEP1 in an indirect yeast three-hybrid assay. To understand the determinants of TEP1–RNA binding, we generated a series of TEP1 deletions and show by yeast three-hybrid assay that the entire Tetrahymena p80 homology region of TEP1 is required for its interaction with both telomerase and VRs. This region is also sufficient to target the protein to the vault particle. Electrophoretic mobility shift assays using the recombinant TEP1 RNA-binding domain (TEP1–RBD) demonstrate that it binds RNA directly, and that telomerase and VRs compete for binding. VR binds weakly to TEP1–RBD in vitro, but mutation of VR sequences predicted to disrupt helices near its central loop enhances binding. Antisense oligonucleotide-directed RNase H digestion of endogenous VR indicates that this region is largely single stranded, suggesting that TEP1 may require access to the VR central loop for efficient binding

    Clinical effectiveness and cost-effectiveness of foot orthoses for people with established rheumatoid arthritis: an exploratory clinical trial

    Get PDF
    Objectives: Foot orthoses are commonly prescribed as an intervention for people with rheumatoid arthritis (RA). Data relating to the cost-effectiveness of foot orthoses in people with RA are limited. The aim was to evaluate the clinical and cost-effectiveness of two types of foot orthoses in people with established RA. Method: A single-blind randomized controlled trial was undertaken to compare custom-made foot orthoses (CMFOs) and simple insoles (SIs) in 41 people with established RA. The Foot Function Index (FFI) was used to measure foot pain, disability, and functional limitation. Costs were estimated from the perspective of the UK National Health Service (NHS), societal (patient and family) perspective, and secondary care resource use in terms of the intervention and staff time. Effects were assessed in terms of health gain expressed as quality-adjusted life years (QALYs). Results: At baseline, 20 participants received a CMFO and 21 participants received an SI. After 16 weeks foot pain improved in both the CMFOs (p = 0.000) and the SIs (p < 0.01). However, disability scores improved for CMFOs (p < 0.001) but not for SIs (p = 0.40). The cost-effectiveness results demonstrated no difference in cost between the arms (CMFOs: £159.10; SIs: £79.10; p = 0.35), with the CMFOs being less effective in terms of cost per QALY gain (p < 0.001). Conclusions: In people with established RA, semi-rigid customized foot orthoses can improve pain and disability scores in comparison to simple insoles. From a cost-effectiveness perspective, the customized foot orthoses were far more expensive to manufacture, with no significant cost per QALY gain

    Percutaneous Transvenous Melody Valve-in-Ring Procedure for Mitral Valve Replacement

    Get PDF
    ObjectivesThe purpose of this study was to demonstrate the feasibility of percutaneous transvenous mitral valve-in-ring (VIR) implantation using the Melody valve in an ovine model.BackgroundThe recurrence of mitral regurgitation following surgical mitral valve (MV) repair in both adult and pediatric patients remains a significant clinical problem. Mitral annuloplasty rings are commonly used in MV repair procedures and may serve as secure landing zones for percutaneous valves.MethodsFive sheep underwent surgical MV annuloplasty (24 mm, n = 2; 26 mm, n = 2; 28 mm, n = 1). Animals underwent cardiac catheterization with VIR implantation via a transfemoral venous, transatrial septal approach 1 week following surgery. Hemodynamic, angiographic, and echocardiographic data were recorded before and after VIR.ResultsVIR was technically successful and required <1 h of procedure time in all animals. Fluoroscopy demonstrated securely positioned Melody valves within the annuloplasty ring in all animals. Angiography revealed no significant MV regurgitation in 4 and moderate central MV regurgitation in the animal with the 28-mm annuloplasty. All animals demonstrated vigorous left ventricular function, no outflow tract obstruction, and no aortic valve insufficiency.ConclusionsThis study demonstrated the feasibility of a purely percutaneous approach to MV replacement in patients with preexisting annuloplasty rings. This novel approach may be of particular benefit to patients with failed repair of ischemic mitral regurgitation and in pediatric patients with complex structural heart disease

    Aluminum Effects in Infants and Children

    Get PDF
    Aluminum has no known biological function; however, it is a contaminant present in most foods and medications. Aluminum is excreted by the renal system, and patients with renal diseases should avoid aluminum-containing medications. Studies demonstrating long-term toxicity from the aluminum content in parenteral nutrition components led the US Food and Drug Administration to implement rules for these solutions. Large-volume ingredients were required to reduce the aluminum concentration, and small-volume components were required to be labeled with the aluminum concentration. Despite these rules, the total aluminum concentration from some components continues to be above the recommended final concentration. The concerns about toxicity from the aluminum present in infant formulas and antiperspirants have not been substantiated but require more research. Aluminum is one of the most effective adjuvants used in vaccines, and a large number of studies have documented minimal adverse effects from this use. Long-term, high-concentration exposure to aluminum has been linked in meta-analyses with the development of Alzheimer disease

    Plasmas and Controlled Nuclear Fusion

    Get PDF
    Contains reports on two research projects.National Science Foundation (Grant GK-2581

    Reliability of capturing foot parameters using digital scanning and the neutral suspension casting technique

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>A clinical study was conducted to determine the intra and inter-rater reliability of digital scanning and the neutral suspension casting technique to measure six foot parameters. The neutral suspension casting technique is a commonly utilised method for obtaining a negative impression of the foot prior to orthotic fabrication. Digital scanning offers an alternative to the traditional plaster of Paris techniques.</p> <p>Methods</p> <p>Twenty one healthy participants volunteered to take part in the study. Six casts and six digital scans were obtained from each participant by two raters of differing clinical experience. The foot parameters chosen for investigation were cast length (mm), forefoot width (mm), rearfoot width (mm), medial arch height (mm), lateral arch height (mm) and forefoot to rearfoot alignment (degrees). Intraclass correlation coefficients (ICC) with 95% confidence intervals (CI) were calculated to determine the intra and inter-rater reliability. Measurement error was assessed through the calculation of the standard error of the measurement (SEM) and smallest real difference (SRD).</p> <p>Results</p> <p>ICC values for all foot parameters using digital scanning ranged between 0.81-0.99 for both intra and inter-rater reliability. For neutral suspension casting technique inter-rater reliability values ranged from 0.57-0.99 and intra-rater reliability values ranging from 0.36-0.99 for rater 1 and 0.49-0.99 for rater 2.</p> <p>Conclusions</p> <p>The findings of this study indicate that digital scanning is a reliable technique, irrespective of clinical experience, with reduced measurement variability in all foot parameters investigated when compared to neutral suspension casting.</p
    corecore