9 research outputs found

    Socioeconomic inequalities in pregnancy outcome associated with Down syndrome: a population-based study.

    Get PDF
    OBJECTIVE: To investigate socioeconomic inequalities in outcome of pregnancy associated with Down syndrome (DS) compared with other congenital anomalies screened for during pregnancy. DESIGN AND SETTING: Retrospective population-based registry study (East Midlands & South Yorkshire in England). PARTICIPANTS: All registered cases of DS and nine selected congenital anomalies with poor prognostic outcome (the UK Fetal Anomaly Screening Programme (FASP)9) with an end of pregnancy date between 1 January 1998 and 31 December 2007. MAIN OUTCOME MEASURES: Poisson regression models were used to explore outcome measures, including socioeconomic variation in rates of anomaly; antenatal detection; pregnancy outcome; live birth incidence and neonatal mortality. Deprivation was measured using the Index of Multiple Deprivation 2004 at super output area level. RESULTS: There were 1151 cases of DS and 1572 cases of the nine severe anomalies combined. The overall rate of antenatal detection was 57% for DS, which decreased with increasing deprivation (rate ratio comparing the most deprived tenth with the least deprived: 0.76 (0.60 to 0.97)). Antenatal detection rates were considerably higher for FASP9 anomalies (86%), with no evidence of a trend with deprivation (0.99 95% CI (0.84 to 1.17)). The termination of pregnancy rate following antenatal diagnosis was higher for DS (86%) than the FASP9 anomalies (70%). Both groups showed wide socioeconomic variation in the termination of pregnancy rate (rate ratio: DS: 0.76 (0.58 to 0.99); FASP9 anomalies: 0.80 (0.65 to 0.97)). Consequently, socioeconomic inequalities in live birth and neonatal mortality rates associated with these anomalies arise that were not observed in utero. CONCLUSIONS: Socioeconomic inequalities exist in the antenatal detection of DS, and subsequent termination rates are much higher for DS than other anomalies. Termination rates for all anomalies are lower in more deprived areas leading to wide socioeconomic inequalities in live born infants with a congenital anomaly, particularly DS, and subsequent neonatal mortality

    Supermarket/Hypermarket Opportunistic Screening for Atrial Fibrillation (SHOPS-AF) using sensors embedded in the handles of supermarket trolleys: A feasibility study

    Get PDF
    BackgroundAtrial fibrillation (AF) increases the risk of death, stroke, heart failure, cognitive decline, and healthcare costs but is often asymptomatic and undiagnosed. There is currently no national screening programme for AF. The advent of validated hand-held devices allows AF to be detected in non-healthcare settings, enabling screening to be undertaken within the community. Method and ResultsIn this novel observational study, we embedded a MyDiagnostick single lead ECG sensor into the handles of shopping trolleys in four supermarkets in the Northwest of England: 2155 participants were recruited. Of these, 231 participants either activated the sensor or had an irregular pulse, suggesting AF. Some participants agreed to use the sensor but refused to provide their contact details, or consent to pulse assessment. In addition, some data were missing, resulting in 203 participants being included in the final analyses. Fifty-nine participants (mean age 73.6 years, 43% female) were confirmed or suspected of having AF; 20 were known to have AF and 39 were previously undiagnosed. There was no evidence of AF in 115 participants and the remaining 46 recordings were non-diagnostic, mainly due to artefact. Men and older participants were significantly more likely to have newly diagnosed AF. Due to the number of non-diagnostic ECGs (n=46), we completed three levels of analyses, excluding all non-diagnostic ECGs, assuming all non-diagnostic ECGs were masking AF, and assuming all non-diagnostic ECGs were not AF. Based on the results of the three analyses, the sensor's sensitivity (95% CI) ranged from 0.70 - 0.93; specificity from 0.15 - 0.97; positive predictive values (PPV) and negative predictive values (NPV) ranged from 0.24 - 0.56 and 0.55-1.00, respectively. These values should be interpreted with caution, as the ideal reference standard on 1934 participants was imperfect. ConclusionThe study demonstrates that the public will engage with AF screening undertaken as part of their daily routines using hand-held devices. Sensors can play a key role in identifying asymptomatic patients in this way, but the technology must be further developed to reduce the quantity of non-diagnostic ECGs

    ā€œBeing Guidedā€: What Oncofertility Patientsā€™ Decisions Can Teach Us About the Efficacy of Autonomy, Agency, and Decision-Making Theory in the Contemporary Critical Encounter

    Get PDF
    Recent research on patient decision-making reveals a disconnect between theories of autonomy, agency, and decision-making and their practice in contemporary clinical encounters. This study examines these concepts in the context of female patients making oncofertility decisions in the United Kingdom in light of the phenomenon of ā€œbeing guided.ā€ Patients experience being guided as a way to cope with, understand, and defer difficult treatment decisions. Previous discussions condemn guided decision-making, but this research suggests that patients make an informed, autonomous decision to be guided by doctors. Thus, bioethicists must consider the multifaceted ways that patients enact their autonomy in medical encounters

    Facilitators and barriers of physical activity participation in children with a single ventricle physiology: a mixed-methods study.

    No full text
    BackgroundThe present study focuses on assessing the physical activity level of children with Fontan circulation for Hypoplastic Left Heart Syndrome and identifying potential barriers and facilitators toward their participation in physical activity.Patients and methodsSeven children aged 5-16 years (mean (SD) 8.8 (3.7) years) with a Fontan procedure for hypoplastic left heart syndrome, their parents (n = 7), and siblings (n = 1) were recruited. Data were collected using a mixed-methods approach: (i) children wore an activity monitor for 7 days to record physical activity, with sedentary time and level of activity calculated from accelerometer data; (ii) children completed a bespoke questionnaire recording limitations in physical activity; (iii) parents completed a semi-structured interview discussing perceptions about their child's physical activity participation. Qualitative data were analysed using thematic analysis.ResultsActivity monitors data recorded highly active children with a mean (SD) of 153(36) minutes/day spent in moderate-to-vigorous physical activity. Time spent in sedentary behaviour was also high (57.5% of total accelerometer wearing-time). Four key themes relating to parental perceptions of physical activity were identified: (i) A new lease of life -post-Fontan; (ii) Setting limits - managing limitations; (iii) The wider world - how others set limits; and (iv) "I fear the future" - parental concerns.ConclusionFollowing completion of the Fontan circulation, children engaged in higher levels of physical activity in comparison to the national average. However, more than half their time was spent in sedentary behaviour. Fears and anxiety from parents and teachers may act as a barrier toward physical activity participation

    Diagnosis of a severe congenital anomaly: a qualitative analysis of parental decision-making and the implications for healthcare encounters.

    No full text
    Most parents-to-be embark on a pregnancy assuming they will have a healthy child but in around 3% of pregnancies a lethal or life-limiting anomaly is present. 1 In the United Kingdom (UK), parents-to-be are offered antenatal screening for 11 congenital anomalies: serious cardiac, anencephaly, spina bifida, renal agenesis, lethal skeletal dysplasia, congenital diaphragmatic hernia, trisomies 13 and 18, cleft lip and gastroschisis through the Fetal Anomaly Screening Programme (FASP). The first nine of these anomalies may be defined as ā€˜severeā€™ as they carry a significant morbidity or mortality risk, and depending on a number of factors, parents-to-be may be offered the option to terminate the affected pregnancy. The other anomalies, cleft lip and gastroschisis, benefit from antenatal or postnatal treatment. 2 In England and Wales, around 70% of women terminate pregnancies affected by a FASP anomaly

    Effectiveness and Safety of Antithrombotic Medication in Patients With Atrial Fibrillation and Intracranial Hemorrhage: Systematic Review and Meta-Analysis

    Get PDF
    BackgroundFor patients with atrial fibrillation who survive an intracranial hemorrhage (ICrH), the decision to offer oral anticoagulation (OAC) is challenging and necessitates balancing risk of thromboembolic events with risk of recurrent ICrH.MethodsThis systematic review assesses the effectiveness and safety of OAC and/or antiplatelets in patients with atrial fibrillation with nontraumatic ICrH. Bibliographic databases CENTRAL, MEDLINE, EMBASE, and CINAHL were searched. Articles on adults with atrial fibrillation with spontaneous ICrH (intracerebral, subdural, and subarachnoid), receiving antithrombotic therapy for stroke prevention were eligible for inclusion.ResultsTwenty articles (50ā€‰470 participants) included 2 randomized controlled trials (n=304)' 8 observational studies, 8 cohort studies, and 2 studies that meta-analyzed individual-level data from observational studies. OAC therapy was associated with a significant reduction in thromboembolic events (summary relative risk [sRR], 0.51 [95% CI, 0.30-0.86], heterogeneity I2=2%; P=0.39, n=5 studies) and all-cause mortality (sRR, 0.52 [95% CI, 0.38-0.71], heterogeneity I2=0; P=0.44, n=3 studies). OAC therapy was not associated with an increased risk of recurrent ICrH (sRR, 1.44 [95% CI, 0.38-5.46], heterogeneity I2=70%, P=0.02, n=5 studies). Nonvitamin K antagonist OACs were more effective at reducing the risk of thromboembolic events (sRR, 0.65 [95% CI, 0.44-0.97], heterogeneity I2=72%, P=0.03, n=3 studies) and were associated with a lower risk of recurrent ICrH (sRR, 0.52 [95% CI, 0.40-0.67], heterogeneity I2=0%, P=0.43, n=3 studies) than warfarin.ConclusionsIn nontraumatic ICrH survivors with atrial fibrillation, OAC therapy is associated with a reduced risk of thromboembolic events and all-cause mortality without significantly increasing risk of recurrent ICrH. This finding is primarily based on observational data, and further larger randomized controlled trials are needed to corroborate or refute these findings

    Socioeconomic inequalities in pregnancy outcome associated with Down Syndrome: a population based study

    No full text
    Objective: To investigate socioeconomic inequalities in outcome of pregnancy associated with Down syndrome (DS) compared with other congenital anomalies screened for during pregnancy. Design & Setting: Retrospective population-based registry study (East Midlands & South Yorkshire in England). Participants: All registered cases of DS and nine selected congenital anomalies with poor prognostic outcome (FASP9) with an end of pregnancy date between 1 January 1998 and 31 December 2007. Main outcome measures: Poisson regression models were used to explore outcome measures including: socioeconomic variation in rates of anomaly; antenatal detection; pregnancy outcome; live birth incidence; and neonatal mortality. Deprivation was measured using the Index of Multiple Deprivation 2004 at super output area level. Results: There were 1151 cases of DS and 1572 cases of the nine severe anomalies combined. The overall rate of antenatal detection was 57% for DS, which decreased with increasing deprivation (Rate ratio comparing the most deprived tenth with the least deprived: 0.76 (0.60 to 0.97)). Antenatal detection rates were considerably higher for FASP9 anomalies (86%), with no evidence of a trend with deprivation (0.99 95% CI (0.84 to 1.17)). The termination of pregnancy rate following antenatal diagnosis was higher for Down syndrome (86%) than the FASP9 anomalies (70%). Both groups showed wide socioeconomic variation in the termination of pregnancy rate (Rate ratio: DS: 0.76, (0.58 to 0.99); FASP9 anomalies: 0.80 (0.65 to 0.97)). Consequently, socioeconomic inequalities in live birth and neonatal mortality rates associated with these anomalies arise that were not observed in utero. Conclusions: Socioeconomic inequalities exist in the antenatal detection of DS, and subsequent termination rates are much higher for DS than other anomalies. Termination rates for all anomalies are lower in more deprived areas leading to wide socioeconomic inequalities in live born infants with a congenital anomaly, particularly DS, and subsequent neonatal mortality

    Supermarket/Hypermarket Opportunistic Screening for Atrial Fibrillation (SHOPS-AF): A Mixed Methods Feasibility Study Protocol

    Get PDF
    Aims: Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia and a key risk factor for ischaemic stroke. Following AF detection, treatment with oral anticoagulation can significantly lower mortality and morbidity rates associated with this risk. The availability of several hand-held devices which can detect AF may enable trained health professionals to adopt AF screening approaches which do not interfere with peopleā€™s daily routines. This study aims to investigate the effectiveness of a hand-held device (the MyDiagnostick single-lead Electrocardiogram (ECG) sensor) in screening for AF when embedded into the handles of supermarket trolleys. Methods: A mixed methods two-phase approach will be taken. The quantitative first phase will involve the recruitment of 2000 participants from a convenience sample at four large supermarkets with pharmacies. Prospective participants will be asked to conduct their shopping using a trolley embedded with a MyDiagnostick sensor. If the device identifies a participant with AF, the in-store pharmacist will be dispatched to take a manual pulse measurement and a static control sensor reading and offer a cardiologist consultation referral. When the sensor does not detect AF, a researcher will confirm the reading with a manual pulse measurement. ECGs will be compiled, and the sensitivity, specificity and positive and negative predictive values will be determined. A qualitative second phase will consist of semi-structured interviews carried out with those pharmacists and store managers in-store during the running of the trial period. These will explore the perceptions of staff regarding the merits of embedding sensors in the handles of supermarket trolleys to detect AF. Conclusion: This feasibility study will inform a larger future definitive trial
    corecore