439 research outputs found

    The structure and composition of exhumed faults, and their implications for seismic processes

    Get PDF
    Field studies of faults exhumed from seismogenic depths provide useful data to constrain seismologic models of fault zone processes and properties. Data collected on the San Andreas Fault in the San Gabriel Mountains has shown that large-displacement faults consist of one to several very narrow slip zones embedded in a cataclastically deformed sheared region several meters thick. However these faults have not been buried to depths greater than 5 km. Fault zones in the Sierra Nevada, California allow us to study the microstructures resulting from the deformation mechanisms active at seismogenic depths. Syn-fault mineralization shows that these left-lateral strike-slip faults formed at 5-12 km depth. Detailed microstructural analyses of the small faults reveal that they evolved from cooling joints filled by chlorite, epidote and quartz. These joints were then reactivated to form shear faults with accompanying brittle fracture and cataclastic deformation, ultimately developing very fined-grained cataclasites and ultracataclasites. The shear-induced microstructures are developed on faults with as little as several mm of slip showing that narrow slip-surfaces develop early in the lifetime of these faults. Subsequent slip has little effect on the microstructures. The inferred similarity of deformation mechanisms in faults 10 m to 10 km long indicates that basic slip processes on the faults are scale invariant, and may be a cause for the inferred constant b-value for small earthquakes. Analysis of map-scale fault linkages and terminations indicate that linkage zones are up to 400 m wide and 1 km long, and consist of altered and fractured rocks with numerous through-going slip surfaces. Terminations are regions of numerous splay faults that have cumulative offsets approaching those of the main faults. The slip distribution and structure of the terminations and linkage zones suggest that seismic slip may propagate into these zones of enhanced toughness, and that through-going slip can occur when a sufficient linkage of faults in the zone allow slip to be transmitted

    The Variability of Sagittarius A* at Centimeter Wavelengths

    Get PDF
    We present the results of a 3.3-year project to monitor the flux density of Sagittarius A* at 2.0, 1.3, and 0.7 cm with the VLA. The fully calibrated light curves for Sgr A* at all three wavelengths are presented. Typical errors in the flux density are 6.1%, 6.2%, and 9.2% at 2.0, 1.3, and 0.7 cm, respectively. There is preliminary evidence for a bimodal distribution of flux densities, which may indicate the existence of two distinct states of accretion onto the supermassive black hole. At 1.3 and 0.7 cm, there is a tail in the distribution towards high flux densities. Significant variability is detected at all three wavelengths, with the largest amplitude variations occurring at 0.7 cm. The rms deviation of the flux density of Sgr A* is 0.13, 0.16, and 0.21 Jy at 2.0, 1.3, and 0.7 cm, respectively. During much of this monitoring campaign, Sgr A* appeared to be relatively quiescent compared to results from previous campaigns. At no point during the monitoring campaign did the flux density of Sgr A* more than double its mean value. The mean spectral index of Sgr A* is alpha=0.20+/-0.01, with a standard deviation of 0.14. The spectral index appears to depend linearly on the observed flux density at 0.7 cm with a steeper index observed during outbursts. This correlation is consistent with the expectation for outbursts that are self-absorbed at wavelengths of 0.7 cm or longer and inconsistent with the effects of simple models for interstellar scintillation. Much of the variability of Sgr A*, including possible time lags between flux density changes at the different wavelengths, appears to occur on time scales less than the time resolution of our observations (8 days). Future observations should focus on the evolution of the flux density on these time scales.Comment: 16 pages, 10 figures, accepted for publication in A

    Analyzing the discharge regime of a large tropical river through remote sensing, ground-based climatic data, and modeling

    Get PDF
    This study demonstrates the potential for applying passive microwave satellite sensor data to infer the discharge dynamics of large river systems using the main stem Amazon as a test case. The methodology combines (1) interpolated ground-based meteorological station data, (2) horizontally and vertically polarized temperature differences (HVPTD) from the 37-GHz scanning multichannel microwave radiometer (SMMR) aboard the Nimbus 7 satellite, and (3) a calibrated water balance/water transport model (WBM/WTM). Monthly HVPTD values at 0.25° (latitude by longitude) resolution were resampled spatially and temporally to produce an enhanced HVPTD time series at 0.5° resolution for the period May 1979 through February 1985. Enhanced HVPTD values were regressed against monthly discharge derived from the WBM/WTM for each of 40 grid cells along the main stem over a calibration period from May 1979 to February 1983 to provide a spatially contiguous estimate of time-varying discharge. HVPTD-estimated flows generated for a validation period from March 1983 to February 1985 were found to be in good agreement with both observed arid modeled discharges over a 1400-km section of the main stem Amazon. This span of river is bounded downstream by a region of tidal influence and upstream by low sensor response associated with dense forest canopy. Both the WBM/WTM and HVPTD-derived flow rates reflect the significant impact of the 1982–1983 El Niño-;Southern Oscillation (ENSO) event on water balances within the drainage basin

    Tactical Surface Metering Procedures for Charlotte Douglas International Airport

    Get PDF
    NASA has been collaborating with the Federal Aviation Administration (FAA) and aviation industry partners to develop and demonstrate new concepts and technologies for the Integrated Arrival, Departure, and Surface (IADS) traffic management capabilities under the Airspace Technology Demonstration 2 (ATD-2) project. The primary goal of the ATD-2 project is to improve the predictability and the operational efficiency of the air traffic system in metroplex environments while maintaining or improving throughput by enhancing and integrating arrival, departure and surface prediction, scheduling, and management systems. In the Phase 1 Baseline IADS Demonstration, the tactical surface scheduling capability and the user interfaces for ramp controllers and ramp traffic managers were implemented for ramp operations. The purpose of the tactical surface scheduling capability is to provide the airline ramp controller with aircraft pushback advisories that prevent surface congestion and to respond to surface and airspace constraints that become known over relatively short time horizons. For this purpose, the tactical surface metering tool first estimates the capacity of current and near-future runway resources from flight schedule and surveillance data. With demand forecasts and predicted taxi trajectories, this tool computes an efficient runway schedule of aircraft in the planning horizon based on their readiness, Earliest Off-Block Times (EOBTs), and a ration by schedule (RBS) rule. Details on the implementation of the Tactical Surface Metering tool will be provided in the full paper. Both pushback and recommended hold times advisories provided by this surface metering tool are shown on the user interfaces for the ramp controller and the ramp traffic manager, called Ramp Traffic Console (RTC) and Ramp Manager Traffic Console (RMTC), respectively. There is excess queue time in the system due to demand capacity imbalance, this time can be taken as a hold on the runway queue or at the gate and was referred to as the Metering Value. This metering value can be adjusted by the Ramp Manager in collaboration with Air Traffic Controller-Tower Traffic Management Coordinator (TMC). They selected a set of metering values as default values for the tool during human-in-the-loop simulation. As the metering value increases, there is a decrease in the gate hold and increase in the queue time at the runway. Procedures and Information needs related to managing the surface metering procedures were researched in the simulated environment. These procedures will be compared to the procedures adopted at Charlotte Douglas International Airport when the tools were deployed and adopted in November 2017 for one departure push bank per day. Feedback regarding initial issues, information needs such as the need to see EOBTs on the flight data tags and how they compare to scheduled times will also be discussed in the full paper. Initial results will be provided regarding the choice of the metering value and how it was adjusted on a daily basis and what procedures evolved will also be presented in the paper

    Elucidation on the Effect of Operating Temperature to the Transport Properties of Polymeric Membrane Using Molecular Simulation Tool

    Get PDF
    Existing reports of gas transport properties within polymeric membrane as a direct consequence of operating temperature are in a small number and have arrived in diverging conclusion. The scarcity has been associated to challenges in fabricating defect free membranes and empirical investigations of gas permeation performance at the laboratory scale that are often time consuming and costly. Molecular simulation has been proposed as a feasible alternative of experimentally studied materials to provide insights into gas transport characteristic. Hence, a sequence of molecular modelling procedures has been proposed to simulate polymeric membranes at varying operating temperatures in order to elucidate its effect to gas transport behaviour. The simulation model has been validated with experimental data through satisfactory agreement. Solubility has shown a decrement in value when increased in temperature (an average factor of 1.78), while the opposite has been observed for gas diffusivity (an average factor of 1.32) when the temperature is increased from 298.15Â K to 323.15Â K. In addition, it is found that permeability decreases by 1.36 times as the temperature is increased

    Global Distribution of Polaromonas Phylotypes - Evidence for a Highly Successful Dispersal Capacity

    Get PDF
    Bacteria from the genus Polaromonas are dominant phylotypes in clone libraries and culture collections from polar and high-elevation environments. Although Polaromonas has been found on six continents, we do not know if the same phylotypes exist in all locations or if they exhibit genetic isolation by distance patterns. To examine their biogeographic distribution, we analyzed all available, long-read 16S rRNA gene sequences of Polaromonas phylotypes from glacial and periglacial environments across the globe. Using genetic isolation by geographic distance analyses, including Mantel tests and Mantel correlograms, we found that Polaromonas phylotypes are globally distributed showing weak isolation by distance patterns at global scales. More focused analyses using discrete, equally sampled distances classes, revealed that only two distance classes (out of 12 total) showed significant spatial structuring. Overall, our analyses show that most Polaromonas phylotypes are truly globally distributed, but that some, as yet unknown, environmental variable may be selecting for unique phylotypes at a minority of our global sites. Analyses of aerobiological and genomic data suggest that Polaromonas phylotypes are globally distributed as dormant cells through high-elevation air currents; Polaromonas phylotypes are common in air and snow samples from high altitudes, and a glacial-ice metagenome and the two sequenced Polaromonas genomes contain the gene hipA, suggesting that Polaromonas can form dormant cells
    • …
    corecore