3,143 research outputs found

    Experiments for satellite and material recovery from orbit. Volume I - Summary Final report

    Get PDF
    Experiment missions for OSO satellite rendezvous, capture, material retrieval, refurbishment, and extravehicular operation wor

    Experiments for Satellite and Material Recovery from Orbit. Volume III - Experiment Missions Final Report

    Get PDF
    Experiment missions for OSO satellite rendezvous, capture, material recovery, refurbishment, and extravehicular operation wor

    Alien Registration- Roach, Howard V. (Fort Fairfield, Aroostook County)

    Get PDF
    https://digitalmaine.com/alien_docs/35746/thumbnail.jp

    Ultrasound increases the aqueous extraction of phenolic compounds with high antioxidant activity from olive pomace

    Get PDF
    Olive pomace is a waste produced by the olive oil industry in massive quantities each year. Disposal of olive pomace is difficult due to high concentrations of phenolic compounds, which is an environmental concern. However, phenolic compounds have applications in the health industry. Therefore, extraction of phenolic compounds from olive pomace has the potential to remove an environmentally hazardous portion of pomace while creating an additional source of income for farmers and producers. Using advanced technologies including Ultrasound Assisted Extraction (UAE), combined with water as an extraction solvent, has recently gained popularity. The present study outlines the optimal UAE conditions for the extraction of phenolic compounds with high antioxidant activity from olive pomace. Optimal conditions were developed using RSM for parameters power, time and sample-to-solvent ratio. Total phenolic compounds determined by Folin Ciocalteu method and total major bioactive compounds determined by HPLC as well as antioxidant capacity (DPPH and CUPRAC) were investigated. The optimal conditions for the extraction of phenolic compounds with high antioxidant activity were 2 g of dried pomace/100 mL of water at 250 W power for 75 min. UAE improved the extraction efficiency of water and yielded extracts with high levels of phenolic compounds and strong antioxidant activity

    Novel method for detection of glycogen in cells

    Get PDF
    Glycogen, a branched polymer of glucose, functions as an energy reserve in many living organisms. Abnormalities in glycogen metabolism, usually excessive accumulation, can be caused genetically, most often through mutation of the enzymes directly involved in synthesis and degradation of the polymer leading to a variety of glycogen storage diseases (GSDs). Microscopic visualization of glycogen deposits in cells and tissues is important for the study of normal glycogen metabolism as well as diagnosis of GSDs. Here, we describe a method for the detection of glycogen using a renewable, recombinant protein which contains the carbohydrate-binding module (CBM) from starch-binding domain containing protein 1 (Stbd1). We generated a fusion protein containing g lutathione S-transferase, a cM c eptitope and the tbd1 BM (GYSC) for use as a glycogen-binding probe, which can be detected with secondary antibodies against glutathione S-transferase or cMyc. By enzyme-linked immunosorbent assay, we demonstrate that GYSC binds glycogen and two other polymers of glucose, amylopectin and amylose. Immunofluorescence staining of cultured cells indicate a GYSC-specific signal that is co-localized with signals obtained with anti-glycogen or anti-glycogen synthase antibodies. GYSC-positive staining inside of lysosomes is observed in individual muscle fibers isolated from mice deficient in lysosomal enzyme acid alpha-glucosidase, a well-characterized model of GSD II (Pompe disease). Co-localized GYSC and glycogen signals are also found in muscle fibers isolated from mice deficient in malin, a model for Lafora disease. These data indicate that GYSC is a novel probe that can be used to study glycogen metabolism under normal and pathological conditions

    Development of a combined surface plasmon resonance/surface acoustic wave device for the characterization of biomolecules

    Get PDF
    It is known that acoustic sensor devices, if operated in liquid phase, are sensitive not just to the mass of the analyte but also to various other parameters, such as size, shape, charge and elastic constants of the analyte as well as bound and viscously entrained water. This can be used to extract valuable information about a biomolecule, particularly if the acoustic device is combined with another sensor element which is sensitive to the mass or amount of analyte only. The latter is true in good approximation for various optical sensor techniques. This work reports on the development of a combined surface plasmon resonance/surface acoustic wave sensor system which is designed for the investigation of biomolecules such as proteins or DNA. Results for the deposition of neutravidin and DNA are reported

    Experiments for satellite and material recovery from orbit. Volume II - Technical Final report

    Get PDF
    Experiment missions for OSO satellite rendezvous, capture, material retrieval, refurbishment, and extravehicular operation wor

    Effect of Magnetization Inhomogeneity on Magnetic Microtraps for Atoms

    Get PDF
    We report on the origin of fragmentation of ultracold atoms observed on a permanent magnetic film atom chip. A novel technique is used to characterize small spatial variations of the magnetic field near the film surface using radio frequency spectroscopy of the trapped atoms. Direct observations indicate the fragmentation is due to a corrugation of the magnetic potential caused by long range inhomogeneity in the film magnetization. A model which takes into account two-dimensional variations of the film magnetization is consistent with the observations.Comment: 4 pages, 4 figure

    Asynchrony adaptation reveals neural population code for audio-visual timing

    Get PDF
    The relative timing of auditory and visual stimuli is a critical cue for determining whether sensory signals relate to a common source and for making inferences about causality. However, the way in which the brain represents temporal relationships remains poorly understood. Recent studies indicate that our perception of multisensory timing is flexible—adaptation to a regular inter-modal delay alters the point at which subsequent stimuli are judged to be simultaneous. Here, we measure the effect of audio-visual asynchrony adaptation on the perception of a wide range of sub-second temporal relationships. We find distinctive patterns of induced biases that are inconsistent with the previous explanations based on changes in perceptual latency. Instead, our results can be well accounted for by a neural population coding model in which: (i) relative audio-visual timing is represented by the distributed activity across a relatively small number of neurons tuned to different delays; (ii) the algorithm for reading out this population code is efficient, but subject to biases owing to under-sampling; and (iii) the effect of adaptation is to modify neuronal response gain. These results suggest that multisensory timing information is represented by a dedicated population code and that shifts in perceived simultaneity following asynchrony adaptation arise from analogous neural processes to well-known perceptual after-effects

    Size-induced distortions in perceptual maps of visual space

    Get PDF
    In order to interact with our environment, the human brain constructs maps of visual space. The orderly mapping of external space across the retinal surface, termed retinotopy, is maintained at subsequent levels of visual cortical processing and underpins our capacity to make precise and reliable judgments about the relative location of objects around us. While these maps, at least in the visual system, support high precision judgments about the relative location of objects, they are prone to significant perceptual distortion. Here, we ask observers to estimate the separation of two visual stimuliVa spatial interval discrimination task. We show that large stimulus sizes require much greater separation in order to be perceived as having the same separation as small stimulus sizes. The relationship is linear, task independent, and unrelated to the perceived position of object edges. We also show that this type of spatial distortion is not restricted to the object itself but can also be revealed by changing the spatial scale of the background, while object size remains constant. These results indicate that fundamental spatial properties, such as retinal image size or the scale at which an object is analyzed, exert a marked influence on spatial coding
    corecore