84 research outputs found

    Systematic review of outcome parameters following treatment of chronic exertional compartment syndrome in the lower leg

    Get PDF
    Objective: Surgery is the gold standard in the management of chronic exertional compartment syndrome (CECS) of the lower extremity, although recent studies also reported success following gait retraining. Outcome parameters are diverse, and reporting is not standardized. The aim of this systematic review was to analyze the current evidence regarding treatment outcome of CECS in the lower leg. Material and Methods: A literature search and systematic analysis were performed according to the PRISMA criteria. Studies reporting on outcome following treatment of lower leg CECS were included. Results: A total of 68 reports fulfilled study criteria (n =; 3783; age range 12-70 year; 7:4 male-to-female ratio). Conservative interventions such as gait retraining (n =; 2) and botulinum injection (n =; 1) decreased ICP ((Formula presented.) =; 68 mm Hg to (Formula presented.) =; 32 mm Hg) and resulted in a 47% (±42%) rate of satisfaction and a 50% (±45%) rate of return to physical activity. Fasciotomy significantly decreased ICP ((Formula presented.) =; 76 mm Hg to (Formula presented.) =; 24 mm Hg) and was associated with an 85% (±13%) rate of satisfaction and an 80% (±17%) rate of return to activity. Return to activity was significantly more often achieved (P <.01) in surgically treated patients, except in one study favoring gait retraining in army personnel. Conclusion: Surgical treatment of CECS in the lower leg results in higher rates of satisfaction and return to activity, compared to conservative treatment. However, the number of studies is limited and the level of evidence is low. Randomized controlled trials with multiple treatment arms and standardized outcome parameters are needed

    Electron Scattering From High-Momentum Neutrons in Deuterium

    Full text link
    We report results from an experiment measuring the semi-inclusive reaction d(e,eâ€Čps)d(e,e'p_s) where the proton psp_s is moving at a large angle relative to the momentum transfer. If we assume that the proton was a spectator to the reaction taking place on the neutron in deuterium, the initial state of that neutron can be inferred. This method, known as spectator tagging, can be used to study electron scattering from high-momentum (off-shell) neutrons in deuterium. The data were taken with a 5.765 GeV electron beam on a deuterium target in Jefferson Laboratory's Hall B, using the CLAS detector. A reduced cross section was extracted for different values of final-state missing mass W∗W^{*}, backward proton momentum p⃗s\vec{p}_{s} and momentum transfer Q2Q^{2}. The data are compared to a simple PWIA spectator model. A strong enhancement in the data observed at transverse kinematics is not reproduced by the PWIA model. This enhancement can likely be associated with the contribution of final state interactions (FSI) that were not incorporated into the model. A ``bound neutron structure function'' F2neffF_{2n}^{eff} was extracted as a function of W∗W^{*} and the scaling variable x∗x^{*} at extreme backward kinematics, where effects of FSI appear to be smaller. For ps>400p_{s}>400 MeV/c, where the neutron is far off-shell, the model overestimates the value of F2neffF_{2n}^{eff} in the region of x∗x^{*} between 0.25 and 0.6. A modification of the bound neutron structure function is one of possible effects that can cause the observed deviation.Comment: 33 pages RevTeX, 9 figures, to be submitted to Phys. Rev. C. Fixed 1 Referenc

    Integrating sequence and array data to create an improved 1000 Genomes Project haplotype reference panel

    Get PDF
    A major use of the 1000 Genomes Project (1000GP) data is genotype imputation in genome-wide association studies (GWAS). Here we develop a method to estimate haplotypes from low-coverage sequencing data that can take advantage of single-nucleotide polymorphism (SNP) microarray genotypes on the same samples. First the SNP array data are phased to build a backbone (or 'scaffold') of haplotypes across each chromosome. We then phase the sequence data 'onto' this haplotype scaffold. This approach can take advantage of relatedness between sequenced and non-sequenced samples to improve accuracy. We use this method to create a new 1000GP haplotype reference set for use by the human genetic community. Using a set of validation genotypes at SNP and bi-allelic indels we show that these haplotypes have lower genotype discordance and improved imputation performance into downstream GWAS samples, especially at low-frequency variants. © 2014 Macmillan Publishers Limited. All rights reserved

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    Get PDF
    Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo

    The Physics of the B Factories

    Get PDF

    Highly-parallelized simulation of a pixelated LArTPC on a GPU

    Get PDF
    The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we present the first implementation of a full microphysical simulator of a liquid argon time projection chamber (LArTPC) equipped with light readout and pixelated charge readout, developed for the DUNE Near Detector. The software is implemented with an end-to-end set of GPU-optimized algorithms. The algorithms have been written in Python and translated into CUDA kernels using Numba, a just-in-time compiler for a subset of Python and NumPy instructions. The GPU implementation achieves a speed up of four orders of magnitude compared with the equivalent CPU version. The simulation of the current induced on 10^3 pixels takes around 1 ms on the GPU, compared with approximately 10 s on the CPU. The results of the simulation are compared against data from a pixel-readout LArTPC prototype

    Xiphodynia as an Unusual Cause of Chest Pain: A Case Series

    No full text
    Introduction Treatment options for xiphodynia are injections with local corticosteroid injections or surgical resection of the xiphoid process. Currently, there is no consensus as to which treatment is the most optimal.Objectives The aim of this case series was to compare the safety and efficacy of conservative and surgical treatment for patients with xiphodynia.Patients and Methods A retrospective case series was performed. All patients presenting with xiphodynia between 2016 and 2021 were eligible. Demographic data and treatment regimes, including preoperative work-up and surgical technique, were extracted from the electronic patient files. In addition, all patients received a follow-up phone call with a questionnaire. Patient satisfaction was measured using the Numeric Rating Scale.Results A total of five patients, suffering from xiphodynia for up to 10 years, completed the follow-up questionnaire (median patient age, 57 years; range 51-68 years). Three of these patients initially received conservative treatment with local injections with corticosteroids for at least 6 months. One patient was satisfied with the results and did not opt for surgical treatment. Eventually, four patients were treated surgically by removing the xiphoid process. No postoperative complications were recorded and 100% of the patients who underwent a xiphoidectomy were free of symptoms and satisfied with the results.Conclusion Symptoms related to xiphodynia can be relieved using conservative or surgical treatment, where the latter seems to be a safe and effective solution
    • 

    corecore