245 research outputs found

    Influence of ocean acidification on the organic complexation of iron and copper in Northwest European shelf seas; a combined observational and model study

    Get PDF
    The pH of aqueous solutions is known to impact the chemical speciation of trace metals. In this study we conducted titrations of coastal seawaters with iron and copper at pH 7.91, 7.37 and 6.99 (expressed on the total pH scale). Changes in the concentration of iron and copper that complexed with the added ligands 1-nitroso-2-napthol and salicylaldoxime respectively were determined by adsorptive cathodic stripping voltammetry - competitive ligand equilibrium (AdCSV-CLE). Interpretation of the results, assuming complexation by a low concentration of discrete ligands, showed that conditional stability constants for iron complexes increased relative to inorganic iron complexation as pH decreased by approximately 1 log unit per pH unit, whilst those for copper did not change. No trend was observed for concentrations of iron and copper complexing ligands over the pH range examined. We also interpreted our titration data by describing chemical binding and polyelectrolytic effects using non-ideal competitive adsorption in Donnan-like gels (NICA-Donnan model) in a proof of concept study. The NICA-Donnan approach allows for the development of a set of model parameters that are independent of ionic strength and pH, and thus calculation of metal speciation can be undertaken at ambient sample pH or the pH of a future, more acidic ocean. There is currently a lack of basic NICA-Donnan parameters applicable to marine dissolved organic matter (DOM) so we assumed that the measured marine dissolved organic carbon could be characterized as terrestrial fulvic acids. Generic NICA-Donnan parameters were applied within the framework of the software program visual MINTEQ and the metal –added ligand concentrations [MeAL] calculated for the AdCSV-CLE conditions. For copper, calculated [MeAL] using the NICA-Donnan model for DOM were consistent with measured [MeAL], but for iron an inert fraction with kinetically inhibited dissolution was required in addition to the NICA-Donnan model in order to approximate the trends observed in measured [MeAL]. We calculated iron and copper speciation in Northwest European shelf water samples at ambient alkalinity and projected increased pCO2 concentrations as a demonstration of the potential of the approach

    Intercomparison of carbonate chemistry measurements on a cruise in northwestern European shelf seas

    Get PDF
    Four carbonate system variables were measured in surface waters during a cruise aimed at investigating ocean acidification impacts traversing northwestern European shelf seas in the summer of 2011. High-resolution surface water data were collected for partial pressure of carbon dioxide (pCO2; using two independent instruments) and pH using the total pH scale (pHT), in addition to discrete measurements of total alkalinity and dissolved inorganic carbon. We thus overdetermined the carbonate system (four measured variables, two degrees of freedom), which allowed us to evaluate the level of agreement between the variables on a cruise whose main aim was not intercomparison, and thus where conditions were more representative of normal working conditions. Calculations of carbonate system variables from other measurements generally compared well with direct observations of the same variables (Pearson’s correlation coefficient always greater than or equal to 0.94; mean residuals were similar to the respective accuracies of the measurements). We therefore conclude that four of the independent data sets of carbonate chemistry variables were of high quality. A diurnal cycle with a maximum amplitude of 41 μatm was observed in the difference between the pCO2 values obtained by the two independent analytical pCO2 systems, and this was partly attributed to irregular seawater flows to the equilibrator and partly to biological activity inside the seawater supply and one of the equilibrators. We discuss how these issues can be addressed to improve carbonate chemistry data quality on future research cruises

    Simulating dynamic facial expressions of pain from visuo-haptic interactions with a robotic patient

    Get PDF
    Medical training simulators can provide a safe and controlled environment for medical students to practice their physical examination skills. An important source of information for physicians is the visual feedback of involuntary pain facial expressions in response to physical palpation on an affected area of a patient. However, most existing robotic medical training simulators that can capture physical examination behaviours in real-time cannot display facial expressions and comprise a limited range of patient identities in terms of ethnicity and gender. Together, these limitations restrict the utility of medical training simulators because they do not provide medical students with a representative sample of pain facial expressions and face identities, which could result in biased practices. Further, these limitations restrict the utility of such medical simulators to detect and correct early signs of bias in medical training. Here, for the first time, we present a robotic system that can simulate facial expressions of pain in response to palpations, displayed on a range of patient face identities. We use the unique approach of modelling dynamic pain facial expressions using a data-driven perception-based psychophysical method combined with the visuo-haptic inputs of users performing palpations on a robot medical simulator. Specifically, participants performed palpation actions on the abdomen phantom of a simulated patient, which triggered the real-time display of six pain-related facial Action Units (AUs) on a robotic face (MorphFace), each controlled by two pseudo randomly generated transient parameters: rate of change β and activation delay τ. Participants then rated the appropriateness of the facial expression displayed in response to their palpations on a 4-point scale from “strongly disagree” to “strongly agree”. Each participant (n=16, 4 Asian females, 4 Asian males, 4 White females and 4 White males) performed 200 palpation trials on 4 patient identities (Black female, Black male, White female and White male) simulated using MorphFace. Results showed facial expressions rated as most appropriate by all participants comprise a higher rate of change and shorter delay from upper face AUs (around the eyes) to those in the lower face (around the mouth). In contrast, we found that transient parameter values of most appropriate-rated pain facial expressions, palpation forces, and delays between palpation actions varied across participant-simulated patient pairs according to gender and ethnicity. These findings suggest that gender and ethnicity biases affect palpation strategies and the perception of pain facial expressions displayed on MorphFace. We anticipate that our approach will be used to generate physical examination models with diverse patient demographics to reduce erroneous judgments in medical students, and provide focused training to address these errors

    Synthesis and characterization of a benzoyl modified Pebax materials for gas separation applications

    Get PDF
    Pebax copolymers produced by Arkema are widely employed for different applications, including active molecular carriers and membranes for gas separation. In the present work, a new modification approach for Pebax®2533 is presented, along with the characterization of the newly obtained materials. Pebax was modified by grafting, through a nucleophilic acyl substitution, a benzoyl group on Polyamide12 block. The yield of the reaction was confirmed by FTIR and NMR analysis, while thermal DSC and TGA characterizations were then carried out on the polymeric products characterized by different degrees of substitution to understand their properties. Finally, self-standing films were obtained by casting and gas permeation tests were conducted at 35 °C using CO2, N2, CH4, O2 and He, in order to understand the potentiality of the new material as membrane for gas separation. DSC showed that in the modified Pebax, named “Benzoyl-P2533” (BP2533), the crystalline phase of the Nylon block was canceled, as expected, but at the same time the degree of crystallinity of the block of Polytetramethyleneoxide increased from 19%, measured for the unmodified Pebax, to a max of 35% for the fully substituted material. For this reason, gas permeability showed small but consistent increment, in the order of 10–11% for most of the gas tested, with the only exception being helium, where the increment resulted to be around 48%. As a consequence, the overall selectivity of CO2 against helium dropped with respect to pristine Pebax. For all the other gases, on the other hand the selectivity with respect to CO2 remained substantially constant, resulting in slight but neat improvement of the ability of the new material to separate this gas

    The measurement of pH in saline and hypersaline media at sub-zero temperatures::Characterization of Tris buffers

    Get PDF
    The pH on the total proton scale of the Tris-HCl buffer system (pHTris) was characterized rigorously with the electrochemical Harned cell in salinity (S) 35 synthetic seawater and S = 45–100 synthetic seawater-derived brines at 25 and 0 °C, as well as at the freezing point of the synthetic solutions (−1.93 °C at S = 35 to −6 °C at S = 100). The electrochemical characterization of the common equimolal Tris buffer [RTris = mTris/mTris‐H+ = 1.0, with mTris = mTris‐H+ = 0.04 mol kgH2O‐1 = molality of the conjugate acid-base pair of 2-amino-2-hydroxymethyl-1,3-propanediol (Tris)] yielded pHTris values which increased with increasing salinity and decreasing temperature. The electrochemical characterization of a non-equimolal Tris buffer variant (RTris = 0.5, with mTris = 0.02 mol kgH2O‐1 and mTris−H+ = 0.04 mol kgH2O‐1) yielded pHTris values that were consistently less alkaline by 0.3 pH unit than those of the equimolal Tris buffer. This is in agreement with the values derived from the stoichiometric equilibrium of the Tris-H+ dissociation reaction, described by the Henderson – Hasselbalch equation, pHTris = pKTris⁎ + logRTris, with pKTris⁎ = stoichiometric equilibrium dissociation constant of Tris-H+, equivalent to equimolal pHTris. This consistency allows reliable use of other RTris variants of the Tris-HCl buffer system within the experimental conditions reported here. The results of this study will facilitate the pH measurement in saline and hypersaline systems at below-zero temperatures, such as sea ice brines

    Characterization of meta-Cresol Purple for spectrophotometric pH measurements in saline and hypersaline media at sub-zero temperatures

    Get PDF
    Accurate pH measurements in polar waters and sea ice brines require pH indicator dyes characterized at near-zero and below-zero temperatures and high salinities. We present experimentally determined physical and chemical characteristics of purified meta-Cresol Purple (mCP) pH indicator dye suitable for pH measurements in seawater and conservative seawater-derived brines at salinities (S) between 35 and 100 and temperatures (T) between their freezing point and 298.15 K (25 °C). Within this temperature and salinity range, using purified mCP and a novel thermostated spectrophotometric device, the pH on the total scale (pHT) can be calculated from direct measurements of the absorbance ratio R of the dye in natural samples as pHT=−log(kT2e2)+log(R−e11−Re3e2) Based on the mCP characterization in these extended conditions, the temperature and salinity dependence of the molar absorptivity ratios and − log(kT2e2) of purified mCP is described by the following functions: e1 = −0.004363 + 3.598 × 10−5T, e3/e2 = −0.016224 + 2.42851 × 10−4T + 5.05663 × 10−5(S − 35), and − log(kT2e2) = −319.8369 + 0.688159 S −0.00018374 S2 + (10508.724 − 32.9599 S + 0.059082S2) T−1 + (55.54253 − 0.101639 S) ln T −0.08112151T. This work takes the characterisation of mCP beyond the currently available ranges of 278.15 K ≤ T ≤ 308.15 K and 20 ≤ S ≤ 40 in natural seawater, thereby allowing high quality pHT measurements in polar systems
    corecore