2,014 research outputs found

    The Nonprofit Quarterly Study on Nonprofit and Philanthropic Infrastructure

    Get PDF
    Examines trends in the nonprofit sector's support network and financing system and their capacity to address the impact of the financial crisis on small and midsize nonprofits, share organizational survival strategies, and connect them to resources

    Design considerations for large space electric power systems

    Get PDF
    As power levels of spacecraft rise to the 50 to 100 kW range, it becomes apparent that low voltage (28 V) dc power distribution and management systems will not operate efficiently at these higher power levels. The concept of transforming a solar array voltage at 150 V dc into a 1000 V ac distribution system operating at 20 kHz is examined. The transformation is accomplished with series-resonant inverter by using a rotary transformer to isolate the solar array from the spacecraft. The power can then be distributed in any desired method such as three phase delta to delta. The distribution voltage can be easily transformed to any desired load voltage and operating frequency. The reasons for the voltage limitations on the solar array due to plasma interactions and the many advantages of a high voltage, high frequency at distribution system are discussed

    Development and evaluation of a small and mobile Magneto Alert Sensor (MALSE) to support safety requirements for magnetic resonance imaging

    Get PDF
    OBJECTIVE: The purpose of this study is to (i) design a small and mobile Magnetic field ALert SEnsor (MALSE), (ii) to carefully evaluate its sensors to their consistency of activation/deactivation and sensitivity to magnetic fields, and (iii) to demonstrate the applicability of MALSE in 1.5 T, 3.0 T and 7.0 T MR fringe field environments. METHODS: MALSE comprises a set of reed sensors, which activate in response to their exposure to a magnetic field. The activation/deactivation of reed sensors was examined by moving them in/out of the fringe field generated by 7TMR. RESULTS: The consistency with which individual reed sensors would activate at the same field strength was found to be 100% for the setup used. All of the reed switches investigated required a substantial drop in ambient magnetic field strength before they deactivated. CONCLUSIONS: MALSE is a simple concept for alerting MRI staff to a ferromagnetic object being brought into fringe magnetic fields which exceeds MALSEs activation magnetic field. MALSE can easily be attached to ferromagnetic objects within the vicinity of a scanner, thus creating a barrier for hazardous situations induced by ferromagnetic parts which should not enter the vicinity of an MR-system to occur

    Dynamics of Stride Interval Characteristics during Continuous Stairmill Climbing

    Get PDF
    It has been shown that statistical persistence in stride intervals characteristics exist during walking, running and cycling and were speed- dependent among healthy young adults. The purpose of this study was to determine if such statistical persistence in stride time interval, stride length and stride speed also exists during self-paced continuous stairmill climbing and if the strength is dependent on stepping rate. Stride time, stride length, and stride speed were collected from nine healthy participants during 3 min of stairmill climbing at 100, 110, and 120% of their preferred stepping rate (PSR) and 5 min of treadmill walking at preferred walking speed (PWS). The amount of variability (assessed by standard deviation and coefficient of variation) and dynamics (assessed by detrended fluctuation analysis and sample entropy) of the stride time, stride length, and stride speed time series were investigated. The amounts of variability were significantly higher during stairmill climbing for the stride time, stride length, and stride speed and did only change with increased stepping rate for stride speed. In addition to a more irregular pattern during stairmill climbing, the detrended fluctuation analysis (DFA) revealed that the stride length fluctuations were statistical anti-persistent for all subjects. On a group level both stride time and stride speed fluctuations were characterized by an uncorrelated pattern which was more irregular compared to that during treadmill walking. However, large inter-participant differences were observed for these two variables. In addition, the dynamics did not change with increase in stepping rate

    Low-count Time Series Anomaly Detection

    Full text link
    Low-count time series describe sparse or intermittent events, which are prevalent in large-scale online platforms that capture and monitor diverse data types. Several distinct challenges surface when modelling low-count time series, particularly low signal-to-noise ratios (when anomaly signatures are provably undetectable), and non-uniform performance (when average metrics are not representative of local behaviour). The time series anomaly detection community currently lacks explicit tooling and processes to model and reliably detect anomalies in these settings. We address this gap by introducing a novel generative procedure for creating benchmark datasets comprising of low-count time series with anomalous segments. Via a mixture of theoretical and empirical analysis, our work explains how widely-used algorithms struggle with the distribution overlap between normal and anomalous segments. In order to mitigate this shortcoming, we then leverage our findings to demonstrate how anomaly score smoothing consistently improves performance. The practical utility of our analysis and recommendation is validated on a real-world dataset containing sales data for retail stores.Comment: 6 pages, 7 figures, to be published in IEEE 2023 Workshop on Machine Learning for Signal Processing (MLSP

    Lower limb joint angle variability and dimensionality are different in stairmill climbing and treadmill walking

    Get PDF
    The present study tested if the quadratic relationship which exists between stepping frequency and gait dynamics in walking can be generalized to stairmill climbing. To accomplish this, we investigated the joint angle dynamics and variability during continuous stairmill climbing at stepping frequencies both above and below the preferred stepping frequency (PSF). Nine subjects performed stairmill climbing at 80, 90, 100, 110 and 120% PSF and treadmill walking at preferred walking speed during which sagittal hip, knee and ankle angles were extracted. Joint angle dynamics were quantified by the largest Lyapunov exponent (LyE) and correlation dimension (CoD). Joint angle variability was estimated by the mean ensemble standard deviation (meanSD). MeanSD and CoD for all joints were significantly higher during stairmill climbing but there were no task differences in LyE. Changes in stepping frequency had only limited effect on joint angle variability and did not affect joint angle dynamics. Thus, we concluded that the quadratic relationship between stepping frequency and gait dynamics observed in walking is not present in stairmill climbing based on the investigated parameters

    ESSKA and EBJIS recommendations for the management of infections after anterior cruciate ligament reconstruction (ACL-R): prevention, surgical treatment and rehabilitation.

    Get PDF
    PURPOSE Infection after anterior cruciate ligament reconstruction (ACL-R) is a rare but severe complication. Despite an increase in articles published on this topic over the last decade, solid data to optimized diagnostic and therapeutic measures are scarce. For this reason, the European Bone and Joint Infection Society (EBJIS) and the European Society for Sports Traumatology, Knee Surgery and Arthroscopy (ESSKA) collaborated in order to develop recommendations for the diagnosis and management of infections after ACL-R. The aim of the workgroup was to perform a review of the literature and provide practical guidance to healthcare professionals involved in the management of infections after ACL-R. METHODS An international workgroup was recruited to provide recommendations for predefined clinical dilemmas regarding the management of infections after ACL-R. MEDLINE, EMBASE, Cochrane Library and Scopus databases were searched for evidence to support the recommended answers to each dilemma. RESULTS The recommendations were divided into two articles. The first covers etiology, prevention, diagnosis and antimicrobial treatment of septic arthritis following ACL-R and is primarily aimed at infectious disease specialists. This article includes the second part of the recommendations and covers prevention of infections after ACL-R, surgical treatment of septic arthritis following ACL-R and subsequent postoperative rehabilitation. It is aimed not only at orthopedic surgeons, but at all healthcare professionals dealing with patients suffering from infections after ACL-R. CONCLUSION These recommendations guide clinicians in achieving timely and accurate diagnosis as well as providing optimal management, both of which are paramount to prevent loss of function and other devastating sequelae of infection in the knee joint. LEVEL OF EVIDENCE V

    Response of the meso- and macro-zooplankton community to long-term environmental changes in the southern North Sea

    Get PDF
    Abstract The North Sea (NS) is changing rapidly. Temporal variations in fishing intensity and eutrophic conditions, along with the ongoing impact of climate change, act in synergy resulting in modifications in marine communities. Although zooplankton has been extensively investigated, studies often ignore the large-sized meso- and macro-zooplankton (&amp;gt;500 µm), including holoplankton and meroplankton taxa. Here, we examined changes in abundances and community structure of these organisms between 1975 and 2018, using univariate and multivariate analysis, at different taxonomic levels. Abrupt changes in the abundances of (sub)communities occurred during different time periods and resulted in a significant restructuration of the entire community in 2006. These changes were consistent with the regime shifts reported in the NS and were a consequence of the environmental pressures on the whole community or on specific subcommunities. In the long term, the community shifted from higher abundances of hydrozoans and holoplankton taxa to an increasing abundance of decapods. Furthermore, we reveal the environmental variables that most explain the variability in the community dynamics, highlighting the importance of temperature and top-down processes. Our study underlines the relevance of investigations at different taxonomic levels, which elucidates how distinct responses to environmental changes ultimately shape the entire community structure.</jats:p

    The improvement of Mo/4H-SiC Schottky diodes via a P2O5 surface passivation treatment

    Get PDF
    Molybdenum (Mo)/4H-silicon carbide (SiC) Schottky barrier diodes have been fabricated with a phosphorus pentoxide (P2O5) surface passivation treatment performed on the SiC surface prior to metallization. Compared to the untreated diodes, the P2O5-treated diodes were found to have a lower Schottky barrier height by 0.11 eV and a lower leakage current by two to three orders of magnitude. Physical characterization of the P2O5-treated Mo/SiC interfaces revealed that there are two primary causes for the improvement in electrical performance. First, transmission electron microscopy imaging showed that nanopits filled with silicon dioxide had formed at the surface after the P2O5 treatment that terminates potential leakage paths. Second, secondary ion mass spectroscopy revealed a high concentration of phosphorus atoms near the interface. While only a fraction of these are active, a small increase in doping at the interface is responsible for the reduction in barrier height. Comparisons were made between the P2O5 pretreatment and oxygen (O2) and nitrous oxide (N2O) pretreatments that do not form the same nanopits and do not reduce leakage current. X-ray photoelectron spectroscopy shows that SiC beneath the deposited P2O5 oxide retains a Si-rich interface unlike the N2O and O2 treatments that consume SiC and trap carbon at the interface. Finally, after annealing, the Mo/SiC interface forms almost no silicide, leaving the enhancement to the subsurface in place, explaining why the P2O5 treatment has had no effect on nickel- or titanium-SiC contacts
    corecore