63 research outputs found

    Indoor Airborne Microbiome and Endotoxin: Meteorological Events and Occupant Characteristics Are Important Determinants

    Get PDF
    Airborne bacteria and endotoxin may affect asthma and allergies. However, there is limited understanding of the environmental determinants that influence them. This study investigated the airborne microbiomes in the homes of 1038 participants from five cities in Northern Europe: Aarhus, Bergen, Reykjavik, Tartu, and Uppsala. Airborne dust particles were sampled with electrostatic dust fall collectors (EDCs) from the participants' bedrooms. The dust washed from the EDCs' clothes was used to extract DNA and endotoxin. The DNA extracts were used for quantitative polymerase chain (qPCR) measurement and 16S rRNA gene sequencing, while endotoxin was measured using the kinetic chromogenic limulus amoebocyte lysate (LAL) assay. The results showed that households in Tartu and Aarhus had a higher bacterial load and diversity than those in Bergen and Reykjavik, possibly due to elevated concentrations of outdoor bacterial taxa associated with low precipitation and high wind speeds. Bergen-Tartu had the highest difference (ANOSIM R = 0.203) in β diversity. Multivariate regression models showed that α diversity indices and bacterial and endotoxin loads were positively associated with the occupants' age, number of occupants, cleaning frequency, presence of dogs, and age of the house. Further studies are needed to understand how meteorological factors influence the indoor bacterial community in light of climate change

    Chronic airflow obstruction and ambient particulate air pollution

    Get PDF
    Smoking is the most well-established cause of chronic airflow obstruction (CAO) but particulate air pollution and poverty have also been implicated. We regressed sex-specific prevalence of CAO from 41 Burden of Obstructive Lung Disease study sites against smoking prevalence from the same study, the gross national income per capita and the local annual mean level of ambient particulate matter (PM2.5) using negative binomial regression. The prevalence of CAO was not independently associated with PM2.5 but was strongly associated with smoking and was also associated with poverty. Strengthening tobacco control and improved understanding of the link between CAO and poverty should be prioritised

    Association of respiratory symptoms and lung function with occupation in the multinational Burden of Obstructive Lung Disease (BOLD) study

    Get PDF
    Background Chronic obstructive pulmonary disease has been associated with exposures in the workplace. We aimed to assess the association of respiratory symptoms and lung function with occupation in the Burden of Obstructive Lung Disease study. Methods We analysed cross-sectional data from 28 823 adults (≥40 years) in 34 countries. We considered 11 occupations and grouped them by likelihood of exposure to organic dusts, inorganic dusts and fumes. The association of chronic cough, chronic phlegm, wheeze, dyspnoea, forced vital capacity (FVC) and forced expiratory volume in 1 s (FEV1)/FVC with occupation was assessed, per study site, using multivariable regression. These estimates were then meta-analysed. Sensitivity analyses explored differences between sexes and gross national income. Results Overall, working in settings with potentially high exposure to dusts or fumes was associated with respiratory symptoms but not lung function differences. The most common occupation was farming. Compared to people not working in any of the 11 considered occupations, those who were farmers for ≥20 years were more likely to have chronic cough (OR 1.52, 95% CI 1.19–1.94), wheeze (OR 1.37, 95% CI 1.16–1.63) and dyspnoea (OR 1.83, 95% CI 1.53–2.20), but not lower FVC (β=0.02 L, 95% CI −0.02–0.06 L) or lower FEV1/FVC (β=0.04%, 95% CI −0.49–0.58%). Some findings differed by sex and gross national income. Conclusion At a population level, the occupational exposures considered in this study do not appear to be major determinants of differences in lung function, although they are associated with more respiratory symptoms. Because not all work settings were included in this study, respiratory surveillance should still be encouraged among high-risk dusty and fume job workers, especially in low- and middle-income countries.publishedVersio

    Patients with asthma or chronic obstructive pulmonary disease (COPD) can generate sufficient inspiratory flows via Easyhaler (R) dry powder inhaler : a pooled analysis of two randomized controlled trials

    Get PDF
    Background: To evaluate whether patients of varying ages and lung function with asthma or those with chronic obstructive pulmonary disease (COPD) can achieve sufficient inspiratory flows for effective use of the fixed-dose combination of salmeterol-fluticasone propionate and budesonide-formoterol dispensed with the Easyhaler (R) (EH) device-metered, multi-dose dry powder inhaler (DPI). Methods: A pooled analysis of two randomized, multicenter, crossover, open-label studies (NCT01424137; NCT009849061) was conducted to characterize inspiratory flow parameters across the EH, Seretide Diskus (DI) and Symbicort Turbuhaler (TH) inhalers in patients with asthma and/or COPD of varying severity. The primary endpoint was peak inspiratory flow (PIF) rate through the EH. Results: The intent-to-treat population comprised 397 patients; 383 patients were included in the per protocol (PP) population. The mean PIF (standard deviation) values through the EH in patients = 18 years of age with asthma and in those with COPD, were similar: 61.4 (11.5), 69.7 (13.5), and 61.9 (13.2) L/min, respectively. These flow rates correspond to pressure drops of 5.05 (1.80), 6.52 (2.34) and 5.19 (2.07) kPa, respectively. In total, 380 (99.2%) of patients in the PP population were able to generate a PIF rate through the EH of >= 30 L/min, which is required to enable consistent dose delivery from the DPI; there was a moderate direct association between age and PIF in younger patients with asthma, but this was inverse and less apparent in adult patients with asthma and/or those with COPD. Height and weight were also moderately correlated with PIF. Stronger associations with PIF were observed for some lung function parameters, particularly native PIF and forced inspiratory vital capacity. Conclusions: Over 99% of patients with asthma and/or COPD were able to inhale through the EH with an adequate PIF rate, irrespective of age, or severity of airway obstruction. This confirms that patients with asthma and/or COPD can achieve inspiratory flows via the EH DPI that are sufficient for its effective use.Peer reviewe

    Volatile organic compounds (VOC) in homes associated with asthma and lung function among adults in Northern Europe

    Get PDF
    Associations between measured specific VOC reported to be associated with dampness and microbial growth in dwellings and asthma, lung function were investigated in 159 adults (one adult/home) from three North European cities (Reykjavik, Uppsala and Tartu). Spirometry was performed and forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1) and FEV1/FVC were measured. Among 159 participants, 58% were females, 24.5% atopics, 25.8% current smokers and 41% reported dampness or mold at home. Dimethyl disulphide (p = 0.004), ethyl isobutyrate (p = 0.021) and ethyl 2-methylbutyrate (p = 0.035) were associated with asthma. Isobutanol (p = 0.043), 3-methyl-1-butanol (p = 0.020), 2-hexanone (p = 0.033), 1-octen-3-ol (p = 0.027), 2-methyl-1-butanol (p = 0.022) and 2-ethyl-1-hexanol (p = 0.045) were associated with lower FEV1. Isobutanol (p = 0.004), 3-methyl-1-butanol (p = 0.001), 2-heptanone (p = 0.047) and 2-methyl-1-butanol (p = 0.002) were associated with lower FEV1/FVC. The association between dimethyl disulphide and asthma was more pronounced in females (p for interaction 0.099). The association between 1-butanol and lower FEV1 was more pronounced in males (p for interaction 0.046). The associations between 3-octanone (p for interaction 0.064), 2-ethyl-1-hexanol (p for interaction 0.049) and lower FEV1, and between 2-heptanone (p for interaction 0.021), 3-octanone (p for interaction 0.008) and lower FEV1/FVC were stronger in homes with dampness/mold. Factor analysis identified one VOC factor related to asthma and two VOC factors related to lower lung function. Increased air concentrations of 2-heptanone, ethyl 2-methylbutyrate and ethyl isobutyrate were related to prescence of certain mold species (Aspergillus sp., Cladosporum sp. and Penicillium sp.) or building dampness. Some VOC were associated with type of dwelling, building age and pet keeping. In conclusion, some VOC reported to be associated with dampness and microbial growth can be associated with asthma and lower lung function in adults. Associations between these VOC and respiratory illness can be stronger in homes with dampness/mold. There can be gender differences in respiratory health effects when exposed to indoor VOC

    Respiratory symptoms, exacerbations and sleep disturbances are more common among participants with asthma and chronic airflow limitation: an epidemiological study in Estonia, Iceland and Sweden

    Get PDF
    Background Chronic airflow limitation (CAL) is a hallmark of chronic obstructive pulmonary disease but is also present in some patients with asthma. We investigated respiratory symptoms, sleep and health status of participants with and without CAL with particular emphasis on concurrent asthma using data from adult populations in Iceland, Estonia and Sweden investigated within the Burden of Obstructive Lung Disease study.Methods All participants underwent spirometry with measurements of forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC) before and after bronchodilation. CAL was defined as postbronchodilator FEV1/FVC below the lower limit of normal. IgE-sensitisation and serum concentrations of eosinophil-derived neurotoxin (S-EDN) were assessed in a subsample. The participants were divided into four groups: no self-reported doctor’s diagnosed asthma or CAL, asthma without CAL, CAL without asthma and asthma and CAL: χ2 test and analysis of variance were used in bivariable analyses and logistic and linear regression when analysing the independent association between respiratory symptoms, exacerbations, sleep-related symptoms and health status towards CAL, adjusting for centre, age, sex, body mass index, smoking history and educational level.Results Among the 1918 participants, 190 (9.9%) had asthma without CAL, 127 (6.6%) had CAL without asthma and 50 (2.6%) had CAL with asthma. Having asthma with CAL was associated with symptoms such as wheeze (adjusted OR (aOR) 6.53 (95% CI 3.53 to 12.1), exacerbations (aOR 12.8 (95% CI 6.97 to 23.6), difficulties initiating sleep (aOR 2.82 (95% CI 1.45 to 5.48), nocturnal gastro-oesophageal reflux (aOR 3.98 (95% CI 1.79 to 8.82)) as well as lower physical health status. In these analyses, those with no asthma and no CAL were the reference group. The prevalence of IgE-sensitisation was highest in both asthma groups, which also had higher levels of S-EDN.Conclusion Individuals with self-reported asthma with CAL suffer from a higher burden of respiratory and sleep-related symptoms, higher exacerbation rates and lower health status when compared with participants with asthma alone or CAL alone

    Airborne molds and bacteria, microbial volatile organic compounds (MVOC), plasticizers and formaldehyde in dwellings in three North European cities in relation to sick building syndrome (SBS).

    No full text
    To access publisher's full text version of this article. Please click on the hyperlink in Additional Links field.There are few studies on associations between airborne microbial exposure, formaldehyde, plasticizers in dwellings and the symptoms compatible with the sick building syndrome (SBS). As a follow-up of the European Community Respiratory Health Survey (ECRHS II), indoor measurements were performed in homes in three North European cities. The aim was to examine whether volatile organic compounds of possible microbial origin (MVOCs), and airborne levels of bacteria, molds, formaldehyde, and two plasticizers in dwellings were associated with the prevalence of SBS, and to study associations between MVOCs and reports on dampness and mold. The study included homes from three centers included in ECRHS II. A total of 159 adults (57% females) participated (19% from Reykjavik, 40% from Uppsala, and 41% from Tartu). A random sample and additional homes with a history of dampness were included. Exposure measurements were performed in the 159 homes of the participants. MVOCs were analyzed by GCMS with selective ion monitoring (SIM). Symptoms were reported in a standardized questionnaire. Associations were analyzed by multiple logistic regression. In total 30.8% reported any SBS (20% mucosal, 10% general, and 8% dermal symptoms) and 41% of the homes had a history of dampness and molds There were positive associations between any SBS and levels of 2-pentanol (P=0.002), 2-hexanone (P=0.0002), 2-pentylfuran (P=0.009), 1-octen-3-ol (P=0.002), formaldehyde (P=0.05), and 2,2,4-trimethyl-1,3-pentanediol monoisobutyrate (Texanol) (P=0.05). 1-octen-3-ol (P=0.009) and 3-methylfuran (P=0.002) were associated with mucosal symptoms. In dwellings with dampness and molds, the levels of total bacteria (P=0.02), total mold (P=0.04), viable mold (P=0.02), 3-methylfuran (P=0.008) and ethyl-isobutyrate (P=0.02) were higher. In conclusion, some MVOCs like 1-octen-3-ol, formaldehyde and the plasticizer Texanol, may be a risk factor for sick building syndrome. Moreover, concentrations of airborne molds, bacteria and some other MVOCs were slightly higher in homes with reported dampness and mold

    Bless this house [music] : song /

    Get PDF
    H. 12299. (Publisher number). No. 3 in E-flat. For voice and piano.; Cover title.; Pl. no.: H. 12299.; Also available online http://nla.gov.au/nla.mus-vn1704967; Copyright 1932 by Boosey & Co. ; Copyright 1927 as 'Bless the house' by Boosey & Co
    • …
    corecore