31 research outputs found
Comparison of breast and bowel cancer screening uptake patterns in a common cohort of South Asian women in England
Background: Inequalities in uptake of cancer screening by ethnic minority populations are well documented in a
number of international studies. However, most studies to date have explored screening uptake for a single cancer
only. This paper compares breast and bowel cancer screening uptake for a cohort of South Asian women invited to
undertake both, and similarly investigates these women's breast cancer screening behaviour over a period of fifteen
years.
Methods: Screening data for rounds 1, 2 and 5 (1989-2004) of the NHS breast cancer screening programme and for
round 1 of the NHS bowel screening pilot (2000-2002) were obtained for women aged 50-69 resident in the English
bowel screening pilot site, Coventry and Warwickshire, who had been invited to undertake breast and bowel cancer
screening in the period 2000-2002. Breast and bowel cancer screening uptake levels were calculated and compared
using the chi-squared test.
Results: 72,566 women were invited to breast and bowel cancer screening after exclusions. Of these, 3,539 were South
Asian and 69,027 non-Asian; 18,730 had been invited to mammography over the previous fifteen years (rounds 1 to 5).
South Asian women were significantly less likely to undertake both breast and bowel cancer screening; 29.9% (n =
1,057) compared to 59.4% (n = 40,969) for non-Asians (p < 0.001). Women in both groups who consistently chose to
undertake breast cancer screening in rounds 1, 2 and 5 were more likely to complete round 1 bowel cancer screening.
However, the likelihood of completion of bowel cancer screening was still significantly lower for South Asians; 49.5% vs.
82.3% for non-Asians, p < 0.001. South Asian women who undertook breast cancer screening in only one round were
no more likely to complete bowel cancer screening than those who decided against breast cancer screening in all
three rounds. In contrast, similar women in the non-Asian population had an increased likelihood of completing the
new bowel cancer screening test. The likelihood of continued uptake of mammography after undertaking screening in
round 1 differed between South Asian religio-linguistic groups. Noticeably, women in the Muslim population were less
likely to continue to participate in mammography than those in other South Asian groups.
Conclusions: Culturally appropriate targeted interventions are required to reduce observed disparities in cancer
screening uptakes
Cholesteatoma of the external ear canal: etiological factors, symptoms and clinical findings in a series of 48 cases
BACKGROUND: To evaluate symptoms, clinical findings, and etiological factors in external ear canal cholesteatoma (EECC). METHOD: Retrospective evaluation of clinical records of all consecutive patients with EECC in the period 1979 to 2005 in a tertiary referral centre. Main outcome measures were incidence rates, classification according to causes, symptoms, extensions in the ear canal including adjacent structures, and possible etiological factors. RESULTS: Forty-five patients were identified with 48 EECC. Overall incidence rate was 0.30 cases per year per 100,000 inhabitants. Twenty-five cases were primary, while 23 cases were secondary: postoperative (n = 9), postinflammatory (n = 5), postirradiatory (n = 7), and posttraumatic (n = 2). Primary EECC showed a right/left ratio of 12/13 and presented with otalgia (n = 15), itching (n = 5), occlusion (n = 4), hearing loss (n = 3), fullness (n = 2), and otorrhea (n = 1). Similar symptoms were found in secondary EECC, but less pronounced. In total the temporomandibular joint was exposed in 11 cases, while the mastoid and middle ear was invaded in six and three cases, respectively. In one primary case the facial nerve was exposed and in a posttraumatic case the atticus and antrum were invaded. In primary EECC 48% of cases reported mechanical trauma. CONCLUSION: EECC is a rare condition with inconsistent and silent symptoms, whereas the extent of destruction may be pronounced. Otalgia was the predominant symptom and often related to extension into nearby structures. Whereas the aetiology of secondary EECC can be explained, the origin of primary EECC remains uncertain; smoking and minor trauma of the ear canal may predispose
Human blood autoantibodies in the detection of colorectal cancer
Colorectal cancer (CRC) is the second most common malignancy in the western world. Early detection and diagnosis of all cancer types is vital to improved prognosis by enabling early treatment when tumours should be both resectable and curable. Sera from 3 different cohorts; 42 sera (21 CRC and 21 matched controls) from New York, USA, 200 sera from Pittsburgh, USA (100 CRC and 100 controls) and 20 sera from Dundee, UK (10 CRC and 10 controls) were tested against a panel of multiple tumour-associated antigens (TAAs) using an optimised multiplex microarray system. TAA specific IgG responses were interpo- lated against the internal IgG standard curve for each sample. Individual TAA specific responses were examined in each cohort to determine cutoffs for a robust initial scoring method to establish sensitivity and specificity. Sensitivity and specificity of combinations of TAAs provided good discrimination between cancer-positive and normal serum. The overall sensitivity and specificity of the sample sets tested against a panel of 32 TAAs were 61.1% and 80.9% respectively for 6 antigens; p53, AFP, K RAS, Annexin, RAF1 and NY-CO16. Furthermore, the observed sensitivity in Pittsburgh sample set in different clinical stages of CRC;stageI(n=19),stageII(n=40),stageIII(n=34)andstageIV(n=6)wassimilar (73.6%, 75.0%, 73.5% and 83.3%, respectively), with similar levels of sensitivity for right and left sided CRC. We identified an antigen panel of sufficient sensitivity and specificity for early detection of CRC, based upon serum profiling of autoantibody response using a robust multiplex antigen microarray technology. This opens the possibility of a blood test for screening and detection of early colorectal cancer. However this panel will require further validation studies before they can be proposed for clinical practice
Design of RNAi Hairpins for Mutation-Specific Silencing of Ataxin-7 and Correction of a SCA7 Phenotype
Spinocerebellar ataxia type 7 is a polyglutamine disorder caused by an expanded CAG repeat mutation that results in neurodegeneration. Since no treatment exists for this chronic disease, novel therapies such post-transcriptional RNA interference-based gene silencing are under investigation, in particular those that might enable constitutive and tissue-specific silencing, such as expressed hairpins. Given that this method of silencing can be abolished by the presence of nucleotide mismatches against the target RNA, we sought to identify expressed RNA hairpins selective for silencing the mutant ataxin-7 transcript using a linked SNP. By targeting both short and full-length tagged ataxin-7 sequences, we show that mutation-specific selectivity can be obtained with single nucleotide mismatches to the wild-type RNA target incorporated 3′ to the centre of the active strand of short hairpin RNAs. The activity of the most effective short hairpin RNA incorporating the nucleotide mismatch at position 16 was further studied in a heterozygous ataxin-7 disease model, demonstrating significantly reduced levels of toxic mutant ataxin-7 protein with decreased mutant protein aggregation and retention of normal wild-type protein in a non-aggregated diffuse cellular distribution. Allele-specific mutant ataxin7 silencing was also obtained with the use of primary microRNA mimics, the most highly effective construct also harbouring the single nucleotide mismatch at position 16, corroborating our earlier findings. Our data provide understanding of RNA interference guide strand anatomy optimised for the allele-specific silencing of a polyglutamine mutation linked SNP and give a basis for the use of allele-specific RNA interference as a viable therapeutic approach for spinocerebellar ataxia 7
Does CT colonography have a role for population-based colorectal cancer screening?
Colorectal cancer (CRC) is the second most common cancer and second most common cause of cancer-related deaths in Europe. CRC screening has been proven to reduce disease-specific mortality and several European countries employ national screening programmes. These almost exclusively rely on stool tests, with endoscopy used as an adjunct in some countries. Computed tomographic colonography (CTC) is a potential screening test, with an estimated sensitivity of 88 % for advanced neoplasia ≥10 mm. Recent randomised studies have shown that CTC and colonoscopy have similar yields of advanced neoplasia per screened invitee, indicating that CTC is potentially viable as a primary screening test. However, the evidence is not fully elaborated. It is unclear whether CTC screening is cost-effective and the impact of extracolonic findings, both medical and economic, remains unknown. Furthermore, the effect of CTC screening on CRC-related mortality is unknown, as it is also unknown for colonoscopy. It is plausible that both techniques could lead to decreased mortality, as for sigmoidoscopy and gFOBT. Although radiation exposure is a drawback, this disadvantage may be over-emphasised. In conclusion, the detection characteristics and acceptability of CTC suggest it is a viable screening investigation. Implementation will depend on detection of extracolonic disease and health-economic impact
Global patient outcomes after elective surgery: prospective cohort study in 27 low-, middle- and high-income countries.
BACKGROUND: As global initiatives increase patient access to surgical treatments, there remains a need to understand the adverse effects of surgery and define appropriate levels of perioperative care. METHODS: We designed a prospective international 7-day cohort study of outcomes following elective adult inpatient surgery in 27 countries. The primary outcome was in-hospital complications. Secondary outcomes were death following a complication (failure to rescue) and death in hospital. Process measures were admission to critical care immediately after surgery or to treat a complication and duration of hospital stay. A single definition of critical care was used for all countries. RESULTS: A total of 474 hospitals in 19 high-, 7 middle- and 1 low-income country were included in the primary analysis. Data included 44 814 patients with a median hospital stay of 4 (range 2-7) days. A total of 7508 patients (16.8%) developed one or more postoperative complication and 207 died (0.5%). The overall mortality among patients who developed complications was 2.8%. Mortality following complications ranged from 2.4% for pulmonary embolism to 43.9% for cardiac arrest. A total of 4360 (9.7%) patients were admitted to a critical care unit as routine immediately after surgery, of whom 2198 (50.4%) developed a complication, with 105 (2.4%) deaths. A total of 1233 patients (16.4%) were admitted to a critical care unit to treat complications, with 119 (9.7%) deaths. Despite lower baseline risk, outcomes were similar in low- and middle-income compared with high-income countries. CONCLUSIONS: Poor patient outcomes are common after inpatient surgery. Global initiatives to increase access to surgical treatments should also address the need for safe perioperative care. STUDY REGISTRATION: ISRCTN5181700
High temporal resolution monitoring of multiple pollutant responses in drainage from an intensively managed grassland catchment caused by a summer storm
This work presents data on a suite of diffuse pollutants, monitored in a stream
draining an intensively managed grassland on a 30 min time step during a period
of intense rainfall to better understand their sources and pathways. Nitrite (92
mu g l(-1)), particulate phosphorus (107 mu g l(-1)) and soluble phosphorus (74
mu g l(-1)) exceeded environmental limits during base flow. Concentrations of
nitrate and nitrite were decreased during the storm event, whereas all other
pollutants generally increased and exceeded environmental limits where
specified, especially when associated with a small subsidiary hydrograph on the
rising limb of the main hydrograph. Total pollutants loads, when using a 60 min
sampling frequency, would have led to significant over and under-estimations
depending on which 60 min sample set was used. In the worst case, loads of
ammonium could have been under-estimated by 35% or over estimated by 25% with
errors being associated with loads on the rising limb of the hydrograph and more
specifically a small subsidiary hydrograph. This subsidiary hydrograph may have
occurred as a result of runoff from the farm hard standings within the
catchment. Incidental transfer of pollutants associate with this runoff have
masked the overall grassland pollutant response. To better understand these
different source areas and pollutant dynamics, there is a need for novel tracing
techniques to elucidate their relative contribution and pathways