24 research outputs found

    Beef empire carcass merit days index system

    Get PDF
    Kansas State University, in cooperation with the Beef Empire Days committee, developed a new beef carcass index system for 1991, incorporating yield and quality traits as indicators of carcass merit. Development of the system considered current industry and consumer demands in a critical evaluation of final carcass ranking. The index starts from 100 points and applies positive and negative adjustments for hot carcass weight; ribeye area; adjusted 12th rib fat thickness; percent kidney, pelvic, and heart fat; and quality grade. The index was first used in 1991

    Measurement of the νe and total 8B solar neutrino fluxes with the Sudbury Neutrino Observatory phase-III data set

    Get PDF
    This paper details the solar neutrino analysis of the 385.17-day phase-III data set acquired by the Sudbury Neutrino Observatory (SNO). An array of 3He proportional counters was installed in the heavy-water target to measure precisely the rate of neutrino-deuteron neutral-current interactions. This technique to determine the total active 8B solar neutrino flux was largely independent of the methods employed in previous phases. The total flux of active neutrinos was measured to be 5.54-0.31+0.33(stat.)-0.34+0.36(syst.)×106 cm-2 s-1, consistent with previous measurements and standard solar models. A global analysis of solar and reactor neutrino mixing parameters yielded the best-fit values of Δm2=7.59-0.21+0.19×10 -5eV2 and θ=34.4-1.2+1.3degrees

    Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) Conceptual Design Report Volume 2: The Physics Program for DUNE at LBNF

    Get PDF
    The Physics Program for the Deep Underground Neutrino Experiment (DUNE) at the Fermilab Long-Baseline Neutrino Facility (LBNF) is described

    Beef empire carcass merit days index system

    Get PDF
    Kansas State University, in cooperation with the Beef Empire Days committee, developed a new beef carcass index system for 1991, incorporating yield and quality traits as indicators of carcass merit. Development of the system considered current industry and consumer demands in a critical evaluation of final carcass ranking. The index starts from 100 points and applies positive and negative adjustments for hot carcass weight; ribeye area; adjusted 12th rib fat thickness; percent kidney, pelvic, and heart fat; and quality grade. The index was first used in 1991

    TOF-OFF: A method for determining focal positions in tightly focused free-electron laser experiments by measurement of ejected ions

    Get PDF
    Pulse intensities greater than 1017 Watt/cm2 were reached at the FLASH soft X-ray laser in Hamburg, Germany, using an off-axis parabolic mirror to focus 15 fs pulses of 5-70 μJ energy at 13.5 nm wavelength to a micron-sized spot. We describe the interaction of such pulses with niobium and vanadium targets and their deuterides. The beam produced craters in the solid targets, and we measured the kinetic energy of ions ejected from these craters. Ions with several keV kinetic energy were observed from craters approaching 5 μm in depth when the sample was at best focus. We also observed the onset of saturation in both ion acceleration and ablation with pulse intensities exceeding 1016 W/cm2, when the highest detected ion energies and the crater depths tend to saturate with increasing intensity. A general difficulty in working with micron and sub-micron focusing optics is finding the exact focus of the beam inside a vacuum chamber. Here we propose a direct method to measure the focal position to a resolution better than the Rayleigh length. The method is based on the correlation between the energies of ejected ions and the physical dimensions of the craters. We find that the focus position can be quickly determined from the ion time-of-flight (TOF) data as the target is scanned through the expected focal region. The method does not require external access to the sample or venting the vacuum chamber. Profile fitting employed to analyze the TOF data can extend resolution beyond the actual scanning step size. © 2011 Elsevier B.V
    corecore