115 research outputs found

    Gaussian process model based predictive control

    Get PDF
    Gaussian process models provide a probabilistic non-parametric modelling approach for black-box identification of non-linear dynamic systems. The Gaussian processes can highlight areas of the input space where prediction quality is poor, due to the lack of data or its complexity, by indicating the higher variance around the predicted mean. Gaussian process models contain noticeably less coefficients to be optimized. This paper illustrates possible application of Gaussian process models within model-based predictive control. The extra information provided within Gaussian process model is used in predictive control, where optimization of control signal takes the variance information into account. The predictive control principle is demonstrated on control of pH process benchmark

    GP-SUM. Gaussian Processes Filtering of non-Gaussian Beliefs

    Full text link
    This work studies the problem of stochastic dynamic filtering and state propagation with complex beliefs. The main contribution is GP-SUM, a filtering algorithm tailored to dynamic systems and observation models expressed as Gaussian Processes (GP), and to states represented as a weighted sum of Gaussians. The key attribute of GP-SUM is that it does not rely on linearizations of the dynamic or observation models, or on unimodal Gaussian approximations of the belief, hence enables tracking complex state distributions. The algorithm can be seen as a combination of a sampling-based filter with a probabilistic Bayes filter. On the one hand, GP-SUM operates by sampling the state distribution and propagating each sample through the dynamic system and observation models. On the other hand, it achieves effective sampling and accurate probabilistic propagation by relying on the GP form of the system, and the sum-of-Gaussian form of the belief. We show that GP-SUM outperforms several GP-Bayes and Particle Filters on a standard benchmark. We also demonstrate its use in a pushing task, predicting with experimental accuracy the naturally occurring non-Gaussian distributions.Comment: WAFR 2018, 16 pages, 7 figure

    Characterization of thermal oxide films formed on a duplex stainless steel by means of confocal-Raman microscopy and electrochemical techniques

    Full text link
    In this work oxide films have been developed on the surface of a duplex stainless steel (UNS 1.4462) using high temperature confocal microscopy to follow their growth. The characteristics of these oxide films have been analyzed by means of weight-gain measurements, Raman microscopy and electrochemical techniques, namely potentiodynamic polarization curves and electrochemical impedance spectroscopy. The results show an increase in the amount of oxides (particularly γ-Fe2O3 and Fe3O4) with temperature. Regarding the electrochemical properties of these films, the corrosion resistance of the film tends to be lower with the heat treatment temperature, probably due to a more porous and heterogeneous scale. Mott–Schottky plots show the n-type semiconductive behavior of the films with donor densities that decrease with the enhancement of the temperature.We wish to express our gratitude to MICINN (CTQ2009-07518) (UPVO8-3E-012), to Universitat Politecnica de Valencia (CEI-01-11), to the Generalitat Valenciana for its help in the CLSM acquisition (MY08/ISIRM/S/100), and to Dr. Asuncion Jaime for her translation assistance.Sánchez Tovar, R.; Leiva García, R.; García Antón, J. (2015). Characterization of thermal oxide films formed on a duplex stainless steel by means of confocal-Raman microscopy and electrochemical techniques. Thin Solid Films. 576:1-10. https://doi.org/10.1016/j.tsf.2014.12.024S11057

    Effect of temperature on passive film formation of UNS N08031 Cr-Ni alloy in phosphoric acid contaminated with different aggressive anions

    Full text link
    tThe influence of temperature and the effect of aggressive anions on the electrochemical behaviour of UNSN08031 stainless steel in a contaminated phosphoric acid solution were evaluated. Stabilisation of thepassive film was studied by potentiodynamic polarisation curves, potentiostatic tests, electrochemicalimpedance spectroscopy (EIS) measurements, Mott Schottky analysis and X-ray photoelectron spec-troscopy (XPS). The stability of the passive film was found to decrease as temperature increases. The filmformed on the stainless steel surface was a n-type semiconductor and the XPS spectrum revealed thepresence of fluoride ions.Authors express their gratitude to the Ministry of Education of Spain (MHE2011-00202) for its financial support during the stay at University of Manchester, to MAEC of Spain (PCI Mediterraneo C/8196/07, C/018046/08, D/023608/09 and D/030177/10) and to the Generalitat Valenciana (GV/2011/093) for the financial support. The authors would also like to acknowledge the support of the School of Materials at the University of Manchester for providing analytical and technical support for the study.Escrivá Cerdán, C.; Blasco Tamarit, ME.; García García, DM.; García Antón, J.; Akid, R.; Walton, J. (2013). Effect of temperature on passive film formation of UNS N08031 Cr-Ni alloy in phosphoric acid contaminated with different aggressive anions. Electrochimica Acta. 111:552-561. https://doi.org/10.1016/j.electacta.2013.08.040S55256111

    The SPECTRA Collaboration OMERACT Special Interest Group: Current Research and Future Directions

    Get PDF
    Objective High-resolution peripheral quantitative computed tomography (HR-pQCT) has the potential to improve radiographic progression determination in clinical trials and longitudinal observational studies. The goal of this work was to describe the current state of research presented at Outcome Measures in Rheumatology (OMERACT) 2016 and ensuing future directions outlined during discussion among attendees. Methods At OMERACT 2016, SPECTRA (Study grouP for xtrEme-Computed Tomography in Rheumatoid Arthritis) introduced efforts to (1) validate the HR-pQCT according to OMERACT guidelines, focusing on rheumatoid arthritis (RA), and (2) find alternatives for automated joint space width (JSW) analysis. The Special Interest Group (SIG) was presented to patient research partners, physicians/researchers, and SIG leaders followed by a 40-min discussion on future directions. Results A consensus definition for RA erosion using HR-pQCT was demonstrated through a systematic literature review and a Delphi exercise. Histopathology and perfusion studies were presented that analyzed the true characteristics of cortical breaks in HR-pQCT images, and to provide criterion validity. Results indicate that readers were able to discriminate between erosion and small vascular channels. Moderate reliability (ICC 0.206–0.871) of direct erosion size measures was shown, which improved (> 0.9) only when experienced readers were considered. Quantification of erosion size was presented for scoring, direct measurement, and volumetric approaches, as well as a reliability exercise for direct measurement. Three methods for JSW measurement were compared, all indicating excellent reproducibility with differences at the extremes (i.e., near-zero and joint edge thickness). Conclusion Initial reports on HR-pQCT are promising; however, to consider its use in clinical trials and longitudinal observational studies, it is imperative to assess the responsiveness of erosion measurement quantification

    Circulating microRNAs as potential diagnostic biomarkers for osteoporosis

    Get PDF
    Osteoporosis is the most common age-related bone disease worldwide and is usually clinically asymptomatic until the first fracture happens. MicroRNAs are critical molecular regulators in bone remodelling processes and are stabilised in the blood. The aim of this project was to identify circulatory microRNAs associated with osteoporosis using advanced PCR arrays initially and the identified differentially-expressed microRNAs were validated in clinical samples using RT-qPCR. A total of 161participants were recruited and 139 participants were included in this study with local ethical approvals prior to recruitment. RNAs were extracted, purified, quantified and analysed from all serum and plasma samples. Differentially-expressed miRNAs were identified using miRNA PCR arrays initially and validated in 139 serum and 134 plasma clinical samples using RT-qPCR. Following validation of identified miRNAs in individual clinical samples using RT-qPCR, circulating miRNAs, hsa-miR-122-5p and hsa-miR-4516 were statistically significantly differentially-expressed between non-osteoporotic controls, osteopaenia and osteoporosis patients. Further analysis showed that the levels of these microRNAs were associated with fragility fracture and correlated with the low bone mineral density in osteoporosis patients. The results show that circulating hsa-miR-122-5p and hsa-miR-4516 could be potential diagnostic biomarkers for osteoporosis in the future
    corecore