40 research outputs found
Experimental investigation of open-ended microwave oven assisted encapsulation process
An open ended microwave oven is presented with improved uniform heating, heating rates and power conversion efficiency. This next generation oven produces more uniform EM fields in the evanescent region forming part of the heating area of the oven. These fields are vital for the rapid and uniform heating of various electromagnetically lossy materials. A fibre optic temperature sensor and an IR pyrometer are used to measure in situ and in real-time the temperature of the curing materials. An automatic computer controlled closed feedback loop measures the temperature in the curing material and drives the microwave components to
obtain predetermined curing temperature cycles for efficient curing. Uniform curing of the lossy encapsulants
is achieved with this oven with typical cure cycle of 270
seconds with a ramp rate of 1oC/s and a hold period of 2
minutes. Differential scanning calorimeter based measurement for the pulsed microwave based curing of
the polymer dielectric indicates a ~ 100% degree of cure
Innovative technologies of waste recycling with production of high performance products
© Published under licence by IOP Publishing Ltd. The innovative ways of recycling wastes as a tool for sustainable development are presented in the article. The technology of the production of a composite material based on the rubber fiber composite waste tire industry is presented. The results of experimental use of the products in the real conditions. The comparative characteristics of the composite material rubber fiber composite are given. The production technology of construction and repairing materials on the basis of foamed glass is presented
Increased spontaneous MEG signal diversity for psychoactive doses of ketamine, LSD and psilocybin
What is the level of consciousness of the psychedelic state? Empirically, measures of neural signal diversity such as entropy and Lempel-Ziv (LZ) complexity score higher for wakeful rest than for states with lower conscious level like propofol-induced anesthesia. Here we compute these measures for spontaneous magnetoencephalographic (MEG) signals from humans during altered states of consciousness induced by three psychedelic substances: psilocybin, ketamine and LSD. For all three, we find reliably higher spontaneous signal diversity, even when controlling for spectral changes. This increase is most pronounced for the single-channel LZ complexity measure, and hence for temporal, as opposed to spatial, signal diversity. We also uncover selective correlations between changes in signal diversity and phenomenological reports of the intensity of psychedelic experience. This is the first time that these measures have been applied to the psychedelic state and, crucially, that they have yielded values exceeding those of normal waking consciousness. These findings suggest that the sustained occurrence of psychedelic phenomenology constitutes an elevated level of consciousness - as measured by neural signal diversity
Using the nonlinear control of anaesthesia-induced hypersensitivity of EEG at burst suppression level to test the effects of radiofrequency radiation on brain function
Background
In this study, investigating the effects of mobile phone radiation on test animals, eleven pigs were anaesthetised to the level where burst-suppression pattern appears in the electroencephalogram (EEG). At this level of anaesthesia both human subjects and animals show high sensitivity to external stimuli which produce EEG bursts during suppression. The burst-suppression phenomenon represents a nonlinear control system, where low-amplitude EEG abruptly switches to very high amplitude bursts. This switching can be triggered by very minor stimuli and the phenomenon has been described as hypersensitivity. To test if also radio frequency (RF) stimulation can trigger this nonlinear control, the animals were exposed to pulse modulated signal of a GSM mobile phone at 890 MHz. In the first phase of the experiment electromagnetic field (EMF) stimulation was randomly switched on and off and the relation between EEG bursts and EMF stimulation onsets and endpoints were studied. In the second phase a continuous RF stimulation at 31 W/kg was applied for 10 minutes. The ECG, the EEG, and the subcutaneous temperature were recorded.
Results
No correlation between the exposure and the EEG burst occurrences was observed in phase I measurements. No significant changes were observed in the EEG activity of the pigs during phase II measurements although several EEG signal analysis methods were applied. The temperature measured subcutaneously from the pigs' head increased by 1.6°C and the heart rate by 14.2 bpm on the average during the 10 min exposure periods.
Conclusion
The hypothesis that RF radiation would produce sensory stimulation of somatosensory, auditory or visual system or directly affect the brain so as to produce EEG bursts during suppression was not confirmed.BioMed Central Open acces
Brain function assessment in different conscious states
Background: The study of brain functioning is a major challenge in neuroscience fields as human brain has a dynamic and ever changing information processing. Case is worsened with conditions where brain undergoes major changes in so-called different conscious states. Even though the exact definition of consciousness is a hard one, there are certain conditions where the descriptions have reached a consensus. The sleep and the anesthesia are different conditions which are separable from each other and also from wakefulness. The aim of our group has been to tackle the issue of brain functioning with setting up similar research conditions for these three conscious states.Methods: In order to achieve this goal we have designed an auditory stimulation battery with changing conditions to be recorded during a 40 channel EEG polygraph (Nuamps) session. The stimuli (modified mismatch, auditory evoked etc.) have been administered both in the operation room and the sleep lab via Embedded Interactive Stimulus Unit which was developed in our lab. The overall study has provided some results for three domains of consciousness. In order to be able to monitor the changes we have incorporated Bispectral Index Monitoring to both sleep and anesthesia conditions.Results: The first stage results have provided a basic understanding in these altered states such that auditory stimuli have been successfully processed in both light and deep sleep stages. The anesthesia provides a sudden change in brain responsiveness; therefore a dosage dependent anesthetic administration has proved to be useful. The auditory processing was exemplified targeting N1 wave, with a thorough analysis from spectrogram to sLORETA. The frequency components were observed to be shifting throughout the stages. The propofol administration and the deeper sleep stages both resulted in the decreasing of N1 component. The sLORETA revealed similar activity at BA7 in sleep (BIS 70) and target propofol concentration of 1.2 μg/mL.Conclusions: The current study utilized similar stimulation and recording system and incorporated BIS dependent values to validate a common approach to sleep and anesthesia. Accordingly the brain has a complex behavior pattern, dynamically changing its responsiveness in accordance with stimulations and states. © 2010 Ozgoren et al; licensee BioMed Central Ltd
Entropy and Complexity Analyses in Alzheimer’s Disease: An MEG Study
Alzheimer’s disease (AD) is one of the most frequent disorders among elderly population and it is considered the main cause of dementia in western countries. This irreversible brain disorder is characterized by neural loss and the appearance of neurofibrillary tangles and senile plaques. The aim of the present study was the analysis of the magnetoencephalogram (MEG) background activity from AD patients and elderly control subjects. MEG recordings from 36 AD patients and 26 controls were analyzed by means of six entropy and complexity measures: Shannon spectral entropy (SSE), approximate entropy (ApEn), sample entropy (SampEn), Higuchi’s fractal dimension (HFD), Maragos and Sun’s fractal dimension (MSFD), and Lempel-Ziv complexity (LZC). SSE is an irregularity estimator in terms of the flatness of the spectrum, whereas ApEn and SampEn are embbeding entropies that quantify the signal regularity. The complexity measures HFD and MSFD were applied to MEG signals to estimate their fractal dimension. Finally, LZC measures the number of different substrings and the rate of their recurrence along the original time series. Our results show that MEG recordings are less complex and more regular in AD patients than in control subjects. Significant differences between both groups were found in several brain regions using all these methods, with the exception of MSFD (p-value < 0.05, Welch’s t-test with Bonferroni’s correction). Using receiver operating characteristic curves with a leave-one-out cross-validation procedure, the highest accuracy was achieved with SSE: 77.42%. We conclude that entropy and complexity analyses from MEG background activity could be useful to help in AD diagnosis
Complexity Analysis of Resting-State MEG Activity in Early-Stage Parkinson's Disease Patients
The aim of the present study was to analyze resting-state brain activity in patients with Parkinson's disease (PD), a degenerative disorder of the nervous system. Magnetoencephalography (MEG) signals were recorded with a 151-channel whole-head radial gradiometer MEG system in 18 early-stage untreated PD patients and 20 age-matched control subjects. Artifact-free epochs of 4 s (1250 samples) were analyzed with Lempel-Ziv complexity (LZC), applying two- and three-symbol sequence conversion methods. The results showed that MEG signals from PD patients are less complex than control subjects' recordings. We found significant group differences (p-values <0.01) for the 10 major cortical areas analyzed (e.g., bilateral frontal, central, temporal, parietal, and occipital regions). In addition, using receiver-operating characteristic curves with a leave-one-out cross-validation procedure, a classification accuracy of 81.58% was obtained. In order to investigate the best combination of LZC results for classification purposes, a forward stepwise linear discriminant analysis with leave-one out cross-validation was employed. LZC results (three-symbol sequence conversion) from right parietal and temporal brain regions were automatically selected by the model. With this procedure, an accuracy of 84.21% (77.78% sensitivity, 90.0% specificity) was achieved. Our findings demonstrate the usefulness of LZC to detect an abnormal type of dynamics associated with PD
The Electroencephalogram as a Biomarker Based on Signal Processing Using Nonlinear Techniques to Detect Dementia
Dementia being a syndrome caused by a brain disease of a chronic or
progressive nature, in which the irreversible loss of intellectual abilities, learning, expressions arises; including memory, thinking, orientation, understanding
and adequate communication, of organizing daily life and of leading a family,
work and autonomous social life; leads to a state of total dependence; therefore,
its early detection and classification is of vital importance in order to serve as
clinical support for physicians in the personalization of treatment programs. The
use of the electroencephalogram as a tool for obtaining information on the
detection of changes in brain activities. This article reviews the types of cognitive spectrum dementia, biomarkers for the detection of dementia, analysis of
mental states based on electromagnetic oscillations, signal processing given by
the electroencephalogram, review of processing techniques, results obtained
where it is proposed the mathematical model about neural networks, discussion
and finally the conclusions
A new method for evaluating the performance of depth-of-hypnosis indices - the D-value
Abstract: An alternative statistic, the D-value, is presented for the evaluation of the performance of EEG-based depth-of-hypnosis measures against the Observers' Assessment of Alertness/Sedation scale. The measures considered here are spectral entropy, approximate entropy, Lempel-Ziv complexity and Higuchi fractal dimension. The study is based on recordings from 45 patients, divided into three groups of 15 recordings each. Patients of Group I received no remifentanil while patients of Groups H and M received 2 and 4 ng/ml effect compartment controlled remifentanil. All the patients received stepwise increased dose of propofol. The study shows that the D-value is a promising and flexible statistic for the evaluation of the discriminative power of the EEG measures with respect to the OAA/S scale. The D-value indicates well the dependence of the performance of the measures on the EEG frequency band as well as on remifentanil concentration
Innovative technologies of waste recycling with production of high performance products
© Published under licence by IOP Publishing Ltd. The innovative ways of recycling wastes as a tool for sustainable development are presented in the article. The technology of the production of a composite material based on the rubber fiber composite waste tire industry is presented. The results of experimental use of the products in the real conditions. The comparative characteristics of the composite material rubber fiber composite are given. The production technology of construction and repairing materials on the basis of foamed glass is presented