203 research outputs found

    Effect of quantum fluctuations on structural phase transitions in SrTiO_3 and BaTiO_3

    Full text link
    Using path-integral Monte Carol simulations and an ab initio effective Hamiltonian, we study the effects of quantum fluctuations on structural phase transitions in the cubic perovskite compounds SrTiO3 and BaTiO3. We find quantum fluctuations affect ferroelectric (FE) transitions more strongly than antiferrodistortive (AFD) ones, even though the effective mass of a single FE local mode is larger. For SrTiO3 we find that the quantum fluctuations suppress the FE transition completely, and reduce the AFD transition temperature from 130K to 110K. For BaTiO3, quantum fluctuations do not affect the order of the transition, but do reduce the transition temperature by 35-50 K. The implications of the calculations are discussed.Comment: Revtex (preprint style, 14 pages) + 2 postscript figures. A version in two-column article style with embedded figures is available at http://electron.rutgers.edu/~dhv/preprints/index.html#wz_qs

    Diagnosing Clostridioides difficile infections with molecular diagnostics: multicenter evaluation of revogene C. difficile assay

    Get PDF
    Clostridioides difficile infections are a significant threat to our healthcare system, and rapid and accurate diagnostics are crucial to implement the necessary infection prevention and control measurements. Nucleic acid amplification tests are such reliable diagnostic tools for the detection of toxigenic Clostridioides difficile strains directly from stool specimens. In this multicenter evaluation, we determined the performance of the revogene C. difficile assay. The analysis was conducted on prospective stool specimens collected from six different sites in Europe. The performance of the revogene C. difficile assay was compared to the different routine diagnostic methods and, for a subset of the specimens, against toxigenic culture. In total, 2621 valid stool specimens were tested, and the revogene C. difficile assay displayed a sensitivity/specificity of 97.1% [93.3-99.0] and 98.9% [98.5-99.3] for identification of Clostridioides difficile infection. Discrepancy analysis using additional methods improved this performance to 98.8% [95.8-99.9] and 99.6% [99.2-99.8], respectively. In comparison to toxigenic culture, the revogene C. difficile assay displayed a sensitivity/specificity of 93.0% [86.1-97.1] and 99.5% [98.7-99.9], respectively. These results indicate that the revogene C. difficile assay is a robust and reliable aid in the diagnosis of Clostridioides difficile infections.This article is freely available via Open Access. Click on the Publisher URL to access it via the publisher's site.This study was supported by grants from GenePOC, now part of Meridian Biosciences.published version, accepted versio

    Vision-based real-time position control of a semi-automated system for robot-assisted joint fracture surgery

    Get PDF
    Purpose: Joint fracture surgery quality can be improved by robotic system with high-accuracy and high-repeatability fracture fragment manipulation. A new real-time vision-based system for fragment manipulation during robot-assisted fracture surgery was developed and tested. Methods: The control strategy was accomplished by merging fast open-loop control with vision-based control. This two-phase process is designed to eliminate the open-loop positioning errors by closing the control loop using visual feedback provided by an optical tracking system. Evaluation of the control system accuracy was performed using robot positioning trials, and fracture reduction accuracy was tested in trials on ex vivo porcine model.Results: The system resulted in high fracture reduction reliability with a reduction accuracy of 0.09mm (translations) and of (Formula presented.) (rotations), maximum observed errors in the order of 0.12mm (translations) and of (Formula presented.) (rotations), and a reduction repeatability of 0.02mm and (Formula presented.). Conclusions: The proposed vision-based system was shown to be effective and suitable for real joint fracture surgical procedures, contributing a potential improvement of their quality

    SARS-CoV-2 N501Y Introductions and Transmissions in Switzerland from Beginning of October 2020 to February 2021-Implementation of Swiss-Wide Diagnostic Screening and Whole Genome Sequencing.

    Get PDF
    The rapid spread of the SARS-CoV-2 lineages B.1.1.7 (N501Y.V1) throughout the UK, B.1.351 (N501Y.V2) in South Africa, and P.1 (B.1.1.28.1; N501Y.V3) in Brazil has led to the definition of variants of concern (VoCs) and recommendations for lineage specific surveillance. In Switzerland, during the last weeks of December 2020, we established a nationwide screening protocol across multiple laboratories, focusing first on epidemiological and microbiological definitions. In January 2021, we validated and implemented an N501Y-specific PCR to rapidly screen for VoCs, which are then confirmed using amplicon sequencing or whole genome sequencing (WGS). A total of 13,387 VoCs have been identified since the detection of the first Swiss case in October 2020, with 4194 being B.1.1.7, 172 B.1.351, and 7 P.1. The remaining 9014 cases of VoCs have been described without further lineage specification. Overall, all diagnostic centers reported a rapid increase of the percentage of detected VOCs, with a range of 6 to 46% between 25 to 31 of January 2021 increasing towards 41 to 82% between 22 to 28 of February. A total of 739 N501Y positive genomes were analysed and show a broad range of introduction events to Switzerland. In this paper, we describe the nationwide coordination and implementation process across laboratories, public health institutions, and researchers, the first results of our N501Y-specific variant screening, and the phylogenetic analysis of all available WGS data in Switzerland, that together identified the early introduction events and subsequent community spreading of the VoCs

    Which medical error to disclose to patients and by whom? Public preference and perceptions of norm and current practice

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Disclosure of near miss medical error (ME) and who should disclose ME to patients continue to be controversial. Further, available recommendations on disclosure of ME have emerged largely in Western culture; their suitability to Islamic/Arabic culture is not known.</p> <p>Methods</p> <p>We surveyed 902 individuals attending the outpatient's clinics of a tertiary care hospital in Saudi Arabia. Personal preference and perceptions of norm and current practice regarding which ME to be disclosed (5 options: don't disclose; disclose if associated with major, moderate, or minor harm; disclose near miss) and by whom (6 options: any employee, any physician, at-fault-physician, manager of at-fault-physician, medical director, or chief executive director) were explored.</p> <p>Results</p> <p>Mean (SD) age of respondents was 33.9 (10) year, 47% were males, 90% Saudis, 37% patients, 49% employed, and 61% with college or higher education. The percentage (95% confidence interval) of respondents who preferred to be informed of harmful ME, of near miss ME, or by at-fault physician were 60.0% (56.8 to 63.2), 35.5% (32.4 to 38.6), and 59.7% (56.5 to 63.0), respectively. Respectively, 68.2% (65.2 to 71.2) and 17.3% (14.7 to 19.8) believed that as currently practiced, harmful ME and near miss ME are disclosed, and 34.0% (30.7 to 37.4) that ME are disclosed by at-fault-physician. Distributions of perception of norm and preference were similar but significantly different from the distribution of perception of current practice (P < 0.001). In a forward stepwise regression analysis, older age, female gender, and being healthy predicted preference of disclosure of near miss ME, while younger age and male gender predicted preference of no-disclosure of ME. Female gender also predicted preferring disclosure by the at-fault-physician.</p> <p>Conclusions</p> <p>We conclude that: 1) there is a considerable diversity in preferences and perceptions of norm and current practice among respondents regarding which ME to be disclosed and by whom, 2) Distributions of preference and perception of norm were similar but significantly different from the distribution of perception of current practice, 3) most respondents preferred to be informed of ME and by at-fault physician, and 4) one third of respondents preferred to be informed of near-miss ME, with a higher percentage among females, older, and healthy individuals.</p

    Towards standardized measurement of adverse events in spine surgery: conceptual model and pilot evaluation

    Get PDF
    BACKGROUND: Independent of efficacy, information on safety of surgical procedures is essential for informed choices. We seek to develop standardized methodology for describing the safety of spinal operations and apply these methods to study lumbar surgery. We present a conceptual model for evaluating the safety of spine surgery and describe development of tools to measure principal components of this model: (1) specifying outcome by explicit criteria for adverse event definition, mode of ascertainment, cause, severity, or preventability, and (2) quantitatively measuring predictors such as patient factors, comorbidity, severity of degenerative spine disease, and invasiveness of spine surgery. METHODS: We created operational definitions for 176 adverse occurrences and established multiple mechanisms for reporting them. We developed new methods to quantify the severity of adverse occurrences, degeneration of lumbar spine, and invasiveness of spinal procedures. Using kappa statistics and intra-class correlation coefficients, we assessed agreement for the following: four reviewers independently coding etiology, preventability, and severity for 141 adverse occurrences, two observers coding lumbar spine degenerative changes in 10 selected cases, and two researchers coding invasiveness of surgery for 50 initial cases. RESULTS: During the first six months of prospective surveillance, rigorous daily medical record reviews identified 92.6% of the adverse occurrences we recorded, and voluntary reports by providers identified 38.5% (surgeons reported 18.3%, inpatient rounding team reported 23.1%, and conferences discussed 6.1%). Trained observers had fair agreement in classifying etiology of 141 adverse occurrences into 18 categories (kappa = 0.35), but agreement was substantial (kappa ≥ 0.61) for 4 specific categories: technical error, failure in communication, systems failure, and no error. Preventability assessment had moderate agreement (mean weighted kappa = 0.44). Adverse occurrence severity rating had fair agreement (mean weighted kappa = 0.33) when using a scale based on the JCAHO Sentinel Event Policy, but agreement was substantial for severity ratings on a new 11-point numerical severity scale (ICC = 0.74). There was excellent inter-rater agreement for a lumbar degenerative disease severity score (ICC = 0.98) and an index of surgery invasiveness (ICC = 0.99). CONCLUSION: Composite measures of disease severity and surgery invasiveness may allow development of risk-adjusted predictive models for adverse events in spine surgery. Standard measures of adverse events and risk adjustment may also facilitate post-marketing surveillance of spinal devices, effectiveness research, and quality improvement

    CD4-Specific Designed Ankyrin Repeat Proteins Are Novel Potent HIV Entry Inhibitors with Unique Characteristics

    Get PDF
    Here, we describe the generation of a novel type of HIV entry inhibitor using the recently developed Designed Ankyrin Repeat Protein (DARPin) technology. DARPin proteins specific for human CD4 were selected from a DARPin DNA library using ribosome display. Selected pool members interacted specifically with CD4 and competed with gp120 for binding to CD4. DARPin proteins derived in the initial selection series inhibited HIV in a dose-dependent manner, but showed a relatively high variability in their capacity to block replication of patient isolates on primary CD4 T cells. In consequence, a second series of CD4-specific DARPins with improved affinity for CD4 was generated. These 2nd series DARPins potently inhibit infection of genetically divergent (subtype B and C) HIV isolates in the low nanomolar range, independent of coreceptor usage. Importantly, the actions of the CD4 binding DARPins were highly specific: no effect on cell viability or activation, CD4 memory cell function, or interference with CD4-independent virus entry was observed. These novel CD4 targeting molecules described here combine the unique characteristics of DARPins—high physical stability, specificity and low production costs—with the capacity to potently block HIV entry, rendering them promising candidates for microbicide development

    Cell-Cell Transmission Enables HIV-1 to Evade Inhibition by Potent CD4bs Directed Antibodies

    Get PDF
    HIV is known to spread efficiently both in a cell-free state and from cell to cell, however the relative importance of the cell-cell transmission mode in natural infection has not yet been resolved. Likewise to what extent cell-cell transmission is vulnerable to inhibition by neutralizing antibodies and entry inhibitors remains to be determined. Here we report on neutralizing antibody activity during cell-cell transmission using specifically tailored experimental strategies which enable unambiguous discrimination between the two transmission routes. We demonstrate that the activity of neutralizing monoclonal antibodies (mAbs) and entry inhibitors during cell-cell transmission varies depending on their mode of action. While gp41 directed agents remain active, CD4 binding site (CD4bs) directed inhibitors, including the potent neutralizing mAb VRC01, dramatically lose potency during cell-cell transmission. This implies that CD4bs mAbs act preferentially through blocking free virus transmission, while still allowing HIV to spread through cell-cell contacts. Thus providing a plausible explanation for how HIV maintains infectivity and rapidly escapes potent and broadly active CD4bs directed antibody responses in vivo
    corecore