294 research outputs found

    The imaging properties of the Gas Pixel Detector as a focal plane polarimeter

    Full text link
    X-rays are particularly suited to probe the physics of extreme objects. However, despite the enormous improvements of X-ray Astronomy in imaging, spectroscopy and timing, polarimetry remains largely unexplored. We propose the photoelectric polarimeter Gas Pixel Detector (GPD) as an instrument candidate to fill the gap of more than thirty years of lack of measurements. The GPD, in the focus of a telescope, will increase the sensitivity of orders of magnitude. Moreover, since it can measure the energy, the position, the arrival time and the polarization angle of every single photon, allows to perform polarimetry of subsets of data singled out from the spectrum, the light curve or the image of source. The GPD has an intrinsic very fine imaging capability and in this work we report on the calibration campaign carried out in 2012 at the PANTER X-ray test facility of the Max-Planck-Institut f\"ur extraterrestrische Physik of Garching (Germany) in which, for the first time, we coupled it to a JET-X optics module with a focal length of 3.5 m and an angular resolution of 18 arcsec at 4.5 keV. This configuration was proposed in 2012 aboard the X-ray Imaging Polarimetry Explorer (XIPE) in response to the ESA call for a small mission. We derived the imaging and polarimetric performance for extended sources like Pulsar Wind Nebulae and Supernova Remnants as case studies for the XIPE configuration, discussing also possible improvements by coupling the detector with advanced optics, having finer angular resolution and larger effective area, to study with more details extended objects.Comment: Accepted for publication in The Astrophysical Journal Supplemen

    Serum KL-6 could represent a reliable indicator of unfavourable outcome in patients with COVID-19 pneumonia

    Get PDF
    KL-6 is a sialoglycoprotein antigen which proved elevated in the serum of patients with different interstitial lung diseases, especially in those with a poorer outcome. Given that interstitial pneumonia is the most common presentation of SARS-CoV2 infection, we evaluated the prognostic role of KL-6 in patients with COVID-19 pneumonia. Patients with COVID-19 pneumonia were prospectively enrolled. Blood samples were collected at the time of enrolment (TOE) and on day 7 (T1). Serum KL-6 concentrations were measured by chemiluminescence enzyme immunoassay using a KL-6 antibody kit (LUMIPULSE G1200, Fujirebio) and the cut-off value was set at > 1000 U/mL. Fifteen out of 34 enrolled patients (44.1%) died. Patients with unfavourable outcome showed significantly lower P/F ratio and higher IL-6 values and plasmatic concentrations of KL-6 at TOE compared with those who survived (median KL-6: 1188 U/mL vs. 260 U/mL, p 1000 U/mL resulted independently associated with death (aOR: 11.29, p 1000 U/mL resulted independently associated with death and showed good accuracy in predicting a poorer outcome. KL-6 may thus represent a quick, inexpensive, and sensitive parameter to stratify the risk of severe respiratory failure and death

    Single photon imaging at ultra-high resolution

    Get PDF
    Abstract We present a detection system capable of imaging both single photon/positive ion and multiple coincidence photons/positive ions with extremely high spatial resolution. In this detector the photoelectrons excited by the incoming photons are multiplied by microchannel plate(s) (MCP). The process of multiplication is spatially constrained within an MCP pore, which can be as small as 4 ÎŒm for commercially available MCPs. An electron cloud originated by a single photoelectron is then encoded by a pixellated custom analog ASIC consisting of 105 K charge sensitive pixels of 50 ÎŒm in size arranged on a hexagonal grid. Each pixel registers the charge with an accuracy o

    Prevalence of HSV1/2 Congenital Infection Assessed Through Genome Detection on Dried Blood Spot in Individuals with Autism Spectrum Disorders

    Get PDF
    Background/Aim: Etiopathogenesis of autism spectrum disorders (ASD) remains to be elucidated. Congenital infections, particularly viral infections, have repeatedly been associated with the onset of such disorders. Our study aimed at assessing the prevalence of herpes simplex type 1 and 2 (HSV1/2) congenital infections in patients with ASD. Materials and Methods: In our case-control study, a total of 38 children with ASD were compared to 44 age- and sex-matched controls regarding the presence of HSV1/2 infection though viral DNA polymerase chain reaction performed on dried blood spots collected at birth. Results: No HSV congenital infection was detected in either group. Conclusion: Our negative finding is in agreement with other studies that failed to demonstrate a definitive role of HSV on the onset of ASD. Further investigation of congenital HSV prevalence in larger and more powerful studies is needed to undeniably discard a role of such virus in the etiopathogenesis of ASD

    Fermi LAT observations of cosmic-ray electrons from 7 GeV to 1 TeV

    Get PDF
    We present the results of our analysis of cosmic-ray electrons using about 8 million electron candidates detected in the first 12 months on-orbit by the Fermi Large Area Telescope. This work extends our previously-published cosmic-ray electron spectrum down to 7 GeV, giving a spectral range of approximately 2.5 decades up to 1 TeV. We describe in detail the analysis and its validation using beam-test and on-orbit data. In addition, we describe the spectrum measured via a subset of events selected for the best energy resolution as a cross-check on the measurement using the full event sample. Our electron spectrum can be described with a power law ∝E−3.08±0.05\propto {\rm E}^{-3.08 \pm 0.05} with no prominent spectral features within systematic uncertainties. Within the limits of our uncertainties, we can accommodate a slight spectral hardening at around 100 GeV and a slight softening above 500 GeV.Comment: 20 pages, 23 figures, 2 tables, published in Physical Review D 82, 092004 (2010) - contact authors: C. Sgro', A. Moisee

    The Small Satellite-Based, Imaging X-Ray Polarimeter Explorer (IXPE) Mission

    Get PDF
    The Imaging X-ray Polarimeter Explorer (IXPE) focuses on high energy astrophysics in the 2—8 keV x-ray band. IXPE is designed to explore general relativistic and quantum physics effects of gravity, energy, electric and magnetic fields at extreme limits. IXPE, a NASA Small Explorer (SMEX) Mission, will add new dimensions to on-orbit x-ray science: polarization degree, polarization angle and extended object polarization imaging. Polarization uniquely probes physical anisotropies that are not otherwise measurable—ordered magnetic fields, aspheric matter distributions, or general relativistic coupling to black-hole spin. Detailed imaging enables the specific properties of extended x-ray sources to be differentiated. The IXPE Observatory consists of spacecraft and payload modules built up in parallel to form the Observatory during system integration and test. The payload includes three polarization-sensitive, x-ray detector arrays paired with three x-ray mirror module assemblies (MMA). A deployable boom provides the correct separation (focal length) between the detector units and MMAs. Currently, the boom has been delivered, all four detectors units (DU) are complete, the detectors service unit (DSU) is complete, instrument system testing has been completed (DSU with 3 DUs), three of four MMAs is built and all spacecraft components except the solar array have been delivered along with the spacecraft and payload structures. Payload and spacecraft integration and test (I&T) started in March 2020. This paper overviews the flight segment (the Observatory, payload, and spacecraft implementation concepts) with emphasis on the build status and summarizes the launch segment. Launch is planned to occur on a Falcon 9 launch vehicle during Summer 2021. The paper summarizes the impacts of switching from the ‘design-to baseline’ of Pegasus XL to the selected launch vehicle for flight, Falcon 9. COVID-19 impacts to the Project are also summarized. The paper will close with a summary of the mission development status. The Project is firmly into the build phase for both the spacecraft and payload and rapidly approaching Observatory I&T

    Multiple endocrine neoplasia type 2 syndromes (MEN 2): results from the ItaMEN network analysis on the prevalence of different genotypes and phenotypes.

    Get PDF
    OBJECTIVE: Multiple endocrine neoplasia type 2 (MEN 2) is a genetic disease characterized by medullary thyroid carcinoma (MTC) associated (MEN 2A and 2B) or not familial MTC (FMTC) with other endocrine neoplasia due to germline RET gene mutations. The prevalence of these rare genetic diseases and their corresponding RET mutations are unknown due to the small size of the study population. METHODS: We collected data on germline RET mutations of 250 families with hereditary MTC followed in 20 different Italian centres. RESULTS AND CONCLUSIONS: The most frequent RET amino acid substitution was Val804Met (19.6%) followed by Cys634Arg (13.6%). A total of 40 different germline RET mutations were present. Six families (2.4%) were negative for germline RET mutations. The comparison of the prevalence of RET germline mutations in the present study with those published by other European studies showed a higher prevalence of Val804Met and Ser891Ala mutations and a lower prevalence of Leu790Phe and Tyr791Phe (P<0.0001). A statistically significant higher prevalence of mutations affecting non-cysteine codons was also found (P<0.0001). Furthermore, the phenotype data collection showed an unexpected higher prevalence of FMTC (57.6%) with respect to other MEN 2 syndromes (34% MEN 2A and 6.8% of MEN 2B). In conclusion, we observed a statistically significant different pattern of RET mutations in Italian MEN 2 families with respect to other European studies and a higher prevalence of FMTC phenotype. The different ethnic origins of the patients and the particular attention given to analysing apparently sporadic MTC for RET germline mutations may explain these findings

    The on-board calibration system of the X-ray Imaging Polarimetry Explorer (XIPE)

    Get PDF
    The calibration system for XIPE is aimed at providing a way to check and correct possible variations of performance of the Gas Pixel Detector during the three years of operation in orbit (plus two years of possible extended operation), while facilitating the observation of the celestial sources. This will be performed by using a filter wheel with a large heritage having a set of positions for the calibration and the observation systems. In particular, it will allow for correcting possible gain variation, for measuring the modulation factor using a polarized source, for removing non interesting bright sources in the field of view and for observing very bright celestial sources. The on-board calibration system is composed of three filter wheels, one for each detector and it is expected to operate for a small number of times during the year. Moreover, since it operates once at a time, within the observation mode, it allows for simultaneous calibration and acquisition from celestial sources on different detectors. In this paper we present the scope and the requirements of the on-board calibration system, its design, and a description of its possible use in space
    • 

    corecore