26 research outputs found

    Does higher gadolinium concentration play a role in the morphologic assessment of brain tumors? Results of a multicenter intraindividual crossover comparison of gadobutrol versus gadobenate dimeglumine (the MERIT Study).

    Get PDF
    BACKGROUND AND PURPOSE: Gadobenate dimeglumine has proved advantageous compared with other gadolinium-based contrast agents for contrast-enhanced brain MR imaging. Gadobutrol is a more highly concentrated agent (1.0 mol/L). This study intraindividually compared 0.1-mmol/kg doses of these agents for qualitative and quantitative evaluation of brain tumors. MATERIALS AND METHODS: Adult patients with suspected or known brain tumors underwent 2 identical MR imaging examinations at 1.5T, 1 with gadobenate dimeglumine and the other with gadobutrol, both at a dose of 0.1-mmol/kg body weight. The agents were injected in randomized order separated by 3–14 days. Imaging sequences and acquisition timing were identical for the 2 examinations. Three blinded readers evaluated images qualitatively for diagnostic information (lesion extent, delineation, morphology, enhancement, global preference) and quantitatively for CNR and LBR. RESULTS: One hundred fourteen of 123 enrolled patients successfully underwent both examinations. Final diagnoses were intra-axial tumors, metastases, extra-axial tumors, "other" tumors, and "nontumor" (49, 46, 8, 7, and 4 subjects, respectively). Readers 1, 2, and 3 demonstrated preference for gadobenate dimeglumine in 46 (40.7%), 54 (47.4%), and 49 (43.0%) patients, respectively, compared with 6, 7, and 7 patients for gadobutrol ( P < .0001, all readers). Highly significant ( P < .0001, all readers) preference for gadobenate dimeglumine was demonstrated for all other qualitative end points. Inter-reader agreement was good for all evaluations (κ = 0.414–0.629). Significantly superior CNR and LBR were determined for gadobenate dimeglumine ( P < .019, all readers). CONCLUSIONS: Significantly greater morphologic information and lesion enhancement are achieved on brain MR imaging with 0.1-mmol/kg gadobenate dimeglumine compared with gadobutrol at an equivalent dose. CNR : contrast-to-noise ratio GBCA : gadolinium-based contrast agent GRE : gradient-recalled echo LBR : lesion-to-background ratio NSF : nephrogenic systemic fibrosis SE : spin-echo SI : signal intensit

    Metastatic myocardial abscess on the posterior wall of the left ventricle: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Myocardial abscess is a rare and potentially fatal condition. Metastatic myocardial abscess in the setting of infective endocarditis has been infrequently reported in the medical literature. To the best of the authors' knowledge no case of myocardial abscess affecting the free wall of the left ventricle secondary to infective endocarditis of a right-sided heart valve has been reported previously.</p> <p>Case presentation</p> <p>We report a case of tricuspid valve endocarditis caused by <it>Staphylococcus aureus </it>and resulting in a myocardial abscess on the posterior wall of the left ventricle, far from the active valvular infection. We also briefly discuss the role of different investigation modalities including cardiac magnetic resonance imaging in diagnosing myocardial abscess.</p> <p>Conclusion</p> <p>Myocardial abscess is a life-threatening illness. A high index of clinical suspicion is required to make a prompt diagnosis. Final diagnosis may need multi-modality imaging. An early diagnosis, aggressive medical therapy, multidisciplinary care and timely surgical intervention may save life in this otherwise fatal condition.</p

    Does Higher Gadolinium Concentration Play a Role in the Morphologic Assessment of Brain Tumors? Results of a Multicenter Intraindividual Crossover Comparison of Gadobutrol versus Gadobenate Dimeglumine (the MERIT Study)

    Get PDF
    BACKGROUND AND PURPOSE:Gadobenate dimeglumine has proved advantageous compared with other gadolinium-based contrast agents for contrast-enhanced brain MR imaging. Gadobutrol is a more highly concentrated agent (1.0 mol/L). This study intraindividually compared 0.1-mmol/kg doses of these agents for qualitative and quantitative evaluation of brain tumors.MATERIALS AND METHODS:Adult patients with suspected or known brain tumors underwent 2 identical MR imaging examinations at 1.5T, 1 with gadobenate dimeglumine and the other with gadobutrol, both at a dose of 0.1-mmol/kg body weight. The agents were injected in randomized order separated by 3-14 days. Imaging sequences and acquisition timing were identical for the 2 examinations. Three blinded readers evaluated images qualitatively for diagnostic information (lesion extent, delineation, morphology, enhancement, global preference) and quantitatively for CNR and LBR.RESULTS:One hundred fourteen of 123 enrolled patients successfully underwent both examinations. Final diagnoses were intra-axial tumors, metastases, extra-axial tumors, "other" tumors, and "nontumor" (49, 46, 8, 7, and 4 subjects, respectively). Readers 1, 2, and 3 demonstrated preference for gadobenate dimeglumine in 46 (40.7\%), 54 (47.4\%), and 49 (43.0\%) patients, respectively, compared with 6, 7, and 7 patients for gadobutrol (P < .0001, all readers). Highly significant (P < .0001, all readers) preference for gadobenate dimeglumine was demonstrated for all other qualitative end points. Inter-reader agreement was good for all evaluations (κ = 0.414-0.629). Significantly superior CNR and LBR were determined for gadobenate dimeglumine (P < .019, all readers).CONCLUSIONS:Significantly greater morphologic information and lesion enhancement are achieved on brain MR imaging with 0.1-mmol/kg gadobenate dimeglumine compared with gadobutrol at an equivalent dose

    Relationship between mitral leaflets angles, left ventricular geometry and mitral deformation indices in patients with ischemic mitral regurgitation: imaging by echocardiography and cardiac magnetic resonance

    Get PDF
    Chronic ischemic mitral regurgitation (IMR) is associated with a markedly worse prognosis after myocardial infarction (MI).The study aimed to evaluate the relationship between anterior and posterior mitral leaflet angle (MLA) values, left ventricle remodeling and severity of ischaemic mitral regurgitation (IMR). Methods: Forty-two patients (age 63.5 ± 9.7 years, 36 men) with chronic IMR (regurgitant volume, RV > 20 ml; >6 months after MI) underwent transthoracic echocardiography (TTE) and cardiovascular magnetic resonance (CMR) imaging. Anterior and posterior MLA, determined by echocardiography, were correlated with indices of LV remodeling, mitral apparatus deformation and IMR severity by CMR. The anterior and posterior MLA was 25.41 ± 4.28 and 38.37 ± 8.89° (mean ± SD). In 5 patients (11.9%) the posterior MLA was ≥45°. There was a significant correlation between anterior MLA and RV (r = 0.74, P = 0.01). For patients with RV > 30 ml this correlation was stronger (r = 0.97, P = 0.005) and, in addition, there was a correlation between the RV and posterior MLA (r = 0.90, P = 0.037), between tenting area and posterior MLA (r = 0.90, P = 0.04), and between tenting area and anterior MLA (r = 0.82, P = 0.08). With regard to LV remodeling parameters, there was weaker but significant correlation between posterior MLA and LV end-diastolic volume index (r = 0.35, P = 0.031), LV end-systolic volume index (r = 0.37, P = 0.021), stroke volume (r = 0.35, P = 0.03), sphericity index (r = 0.33, P = 0.041). Anterior MLA correlated with wall motion score index (r = 0.41, P = 0.019). Besides, there was a correlation between posterior MLA and left atrial volume (r = 0.41, P = 0.012). Measurement of anterior and posterior MLA may play an important role in evaluating patients with IMR

    Renal artery stenosis evaluation: diagnostic performance of gadobenate dimeglumine-enhanced MR angiography--comparison with DSA

    Get PDF
    PURPOSE: To prospectively determine diagnostic performance and safety of contrast material-enhanced (CE) magnetic resonance (MR) angiography with 0.1 mmol per kilogram of body weight gadobenate dimeglumine for depiction of significant steno-occlusive disease (> or =51% stenosis) of renal arteries, with digital subtraction angiography (DSA) as reference standard. MATERIALS AND METHODS: This multicenter study was approved by local institutional review boards; all patients provided written informed consent. Patient enrollment and examination at centers in the United States complied with HIPAA. Two hundred ninety-three patients (154 men, 139 women; mean age, 61.0 years) with severe hypertension (82.2%), progressive renal failure (11.3%), and suspected renal artery stenosis (6.5%) underwent CE MR angiography with three-dimensional spoiled gradient-echo sequences after administration of 0.1 mmol/kg gadobenate dimeglumine at 2 mL/sec. Anteroposterior and oblique DSA was performed in 268 (91.5%) patients. Three independent blinded reviewers evaluated CE MR angiographic images. Sensitivity, specificity, and accuracy of CE MR angiography for detection of significant steno-occlusive disease (> or =51% vessel lumen narrowing) were determined at segment (main renal artery) and patient levels. Positive and negative predictive values and positive and negative likelihood ratios were determined. Interobserver agreement was analyzed with generalized kappa statistics. A safety evaluation (clinical examination, electrocardiogram, blood and urine analysis, monitoring for adverse events) was performed. RESULTS: Of 268 patients, 178 who were evaluated with MR angiography and DSA had significant steno-occlusive disease of renal arteries at DSA. Sensitivity, specificity, and accuracy of CE MR angiography for detection of 51% or greater stenosis or occlusion were 60.1%-84.1%, 89.4%-94.7%, and 80.4%-86.9%, respectively, at segment level. Similar values were obtained for predictive values and for patient-level analyses. Few CE MR angiographic examinations (1.9%-2.8%) were technically inadequate. Interobserver agreement for detection of significant steno-occlusive disease was good (79.9% agreement; kappa = 0.69). No safety concerns were noted. CONCLUSION: CE MR angiography performed with 0.1 mmol/kg gadobenate dimeglumine, compared with DSA, is safe and provides good sensitivity, specificity, and accuracy for detection of significant renal artery steno-occlusive disease

    Poster display II clinical general

    Get PDF
    corecore