131 research outputs found

    Depth Evaluation of Soft Tissue Mimicking Phantoms Using Surface Acoustic Waves

    Get PDF
    AbstractSurface acoustic wave (SAW) shows advantages in revealing skin mechanical properties. In this paper, we evaluates the elasticity of tissue mimicking phantoms by inversion of SAWs phase velocity to Young's Modulus, the estimated SAWs evaluating depth is determined based on the assumption of that SAWs penetration approximately equals one wavelength. The tissue mimicking phantoms are made of agar with concentration of 1%, 2% and 3%. Their elasticity tested from our system is 13.3kPa, 53.4kPa and 257.9kPa respectively, with expected gradient. The evaluation depth is then estimated as 0.542mm to 3.403mm underneath the phantom surface, which indicates that this method is suitable to measure elasticity in dermis layer of skin

    In vivo measurement of skin surface strain and sub-surface layer deformation induced by natural tissue stretching.

    Get PDF
    Stratum corneum and epidermal layers change in terms of thickness and roughness with gender, age and anatomical site. Knowledge of the mechanical and tribological properties of skin associated with these structural changes are needed to aid in the design of exoskeletons, prostheses, orthotics, body mounted sensors used for kinematics measurements and in optimum use of wearable on-body devices. In this case study, optical coherence tomography (OCT) and digital image correlation (DIC) were combined to determine skin surface strain and sub-surface deformation behaviour of the volar forearm due to natural tissue stretching. The thickness of the epidermis together with geometry changes of the dermal-epidermal junction boundary were calculated during change in the arm angle, from flexion (90°) to full extension (180°). This posture change caused an increase in skin surface Lagrange strain, typically by 25% which induced considerable morphological changes in the upper skin layers evidenced by reduction of epidermal layer thickness (20%), flattening of the dermal-epidermal junction undulation (45-50% reduction of flatness being expressed as Ra and Rz roughness profile height change) and reduction of skin surface roughness Ra and Rz (40-50%). The newly developed method, DIC combined with OCT imaging, is a powerful, fast and non-invasive methodology to study structural skin changes in real time and the tissue response provoked by mechanical loading or stretching

    A comparison of friction behaviour for ex vivo human, tissue engineered and synthetic skin

    Get PDF
    Skin tribology is complex and in situ behaviour of skin varies considerably between test subjects. The main influencing factor, elasticity, varies due to structural and moisture differences. To find a more reliable test platform, for the first time, synthetic and biological (tissue engineered) substitutes were compared to ex vivo skin, epidermis and dermis. Friction initially increased with rising hydration, before decreasing beyond a threshold for all samples. Friction for Synthetic skin and dermis increased at a similar rate to the other samples, but from a different starting point, and friction dropped at lower hydration. Tissue engineered skin could provide a reliable test platform, but the synthetic skin could only be used if the offset in the data is accounted for

    Quantitative diagnostics of soft tissue through viscoelastic characterization using time-based instrumented palpation

    Get PDF
    AbstractAlthough palpation has been successfully employed for centuries to assess soft tissue quality, it is a subjective test, and is therefore qualitative and depends on the experience of the practitioner. To reproduce what the medical practitioner feels needs more than a simple quasi-static stiffness measurement. This paper assesses the capacity of dynamic mechanical palpation to measure the changes in viscoelastic properties that soft tissue can exhibit under certain pathological conditions. A diagnostic framework is proposed to measure elastic and viscous behaviors simultaneously using a reduced set of viscoelastic parameters, giving a reliable index for quantitative assessment of tissue quality. The approach is illustrated on prostate models reconstructed from prostate MRI scans. The examples show that the change in viscoelastic time constant between healthy and cancerous tissue is a key index for quantitative diagnostics using point probing. The method is not limited to any particular tissue or material and is therefore useful for tissue where defining a unique time constant is not trivial. The proposed framework of quantitative assessment could become a useful tool in clinical diagnostics for soft tissue

    Constitutive modelling of skin ageing

    Get PDF
    The objective of this chapter is to review the main biomechanical and structural aspects associated with both intrinsic and extrinsic skin ageing, and to present potential research avenues to account for these effects in mathematical and computational models of the skin. This will be illustrated through recent work of the authors which provides a basis to those interested in developing mechanistic constitutive models capturing the mechanobiology of skin across the life course

    Interpretation of the human skin biotribological behaviour after tape stripping

    No full text
    The present study deals with the modification of the human skin biotribological behaviour after tape stripping. The tape-stripping procedure consists in the sequential application and removal of adhesive tapes on the skin surface in order to remove stratum corneum (SC) layers, which electrically charges the skin surface. The skin electric charges generated by tape stripping highly change the skin friction behaviour by increasing the adhesion component of the skin friction coefficient. It has been proposed to rewrite the friction adhesion component as the sum of two terms: the first classical adhesion term depending on the intrinsic shear strength, τ0, and the second term depending on the electric shear strength, τelec. The experimental results allowed to estimate a numerical value of the electric shear strength τelec. Moreover, a plan capacitor model with a dielectric material inside was used to modelize the experimental system. This physical model permitted to evaluate the friction electric force and the electric shear strength values to calculate the skin friction coefficient after the tape stripping. The comparison between the experimental and the theoretical value of the skin friction coefficient after the tape stripping has shown the importance of the electric charges on skin biotribological behaviour. The static electric charges produced by tape stripping on the skin surface are probably able to highly modify the interaction of formulations with the skin surface and their spreading properties. This phenomenon, generally overlooked, should be taken into consideration as it could be involved in alteration of drug absorption

    Ski de fond : simulation de l'usure sur la glace

    No full text
    Apport des recherches en tribologie, étude du frottement et de ses effets, pour les compétiteurs et entraîneurs de ski de fond

    In vivo skin biophysical behaviour and surface topography as a function of ageing

    No full text
    International audienceNormal skin ageing is characterised by an alteration of the underlying connective tissue with measurable consequences on global skin biophysical properties. The cutis laxa syndrome, a rare genetic disorder, is considered as an accelerated ageing process since patients appear prematurely aged due to alterations of dermal elastic fibres. In the present study, we compared the topography and the biomechanical parameters of normal aged skin with an 17 year old cutis laxa patient. Skin topography analyses were conducted on normal skin at different ages. The results indicate that the skin relief highly changes as a function of ageing. The cutaneous lines change from a relatively isotropic orientation to a highly anisotropic orientation. This reorganisation of the skin relief during the ageing process might be due to a modification of the skin mechanical properties, and particularly to a modification of the dermis mechanical properties. A specific bio-tribometer, based on the indentationtechnique under light load, has been developed to study the biophysical properties of the human skin in vivo through two main parameters: the physico-chemical properties of the skin surface, by measuring the maximum adhesion force between the skin and the bio-tribometer; and the bulk mechanical properties. Our results show that the pull-off force between the skin and the biotribometer as well as the skin Young's modulus decrease with age. In the case of the young cutis laxa patient, the results obtained were similar to those observed for aged individuals. These results are very interesting and encouraging since they would allow the monitoring of the cutis laxa skin in a standardised and non-invasive way to better characterize either the evolution of the disease or the benefit of a treatment
    corecore