616 research outputs found
A stretcher and holder module
Abstract This paper describes the general structure and the performance of a compact module, designed to stretch and hold analog signals up to several hundreds of microseconds, without remarkable changes in the pulse height and shape, and to provide a convenient interface between detector systems and data acquisition equipment
Recommended from our members
THE CONTROLLED DRIFT DETECTOR : CHARACTERISATION OF THE READOUT MECHANISM AND OF THE CHARGE HANDLING CAPABILITY.
A new position-sensing X-ray detector operated in integrate-readout mode has been recently designed and characterized. Due to the peculiar working principle of the new detector, the charge handling capability, that is the maximum charge that can be stored in a pixel, is related to the operating conditions of the device. In particular the amplitude of the barriers that confine the signal electrons during the integration phase depends on the applied drift field and on the field perturbation superposed to it. A detailed experimental characterization of the charge handling capability as a function of these parameters has been carried out
The controlled-drift detector,”
Abstract A new position-sensing X-ray detector is presented. The novel device is called Controlled-Drift Detector (CDD). The detector is fully depleted and is operated by switching between integration and drift modes. The relevant details of the detector design are discussed. A complete experimental characterization of the fast readout of the integrated signal charges achievable with static drift "elds in the range 100}400 V/cm has been carried out. Preliminary measurements to evaluate the charge-handling capacity are also shown. The CDD can provide unambiguous two-dimensional position measurement, high-resolution X-ray spectroscopy and time resolution below 1 ms
Predicting PCB concentrations in cow milk: validation of a fugacity model in high-mountain pasture conditions
A fugacity model reported in the literature was applied to a high - altitude pasture in the Italian Alps. The model takes into account three compartments (digestive tract, blood and fat tissues) in unsteady-state conditions using food as the contamination source. Disregarding biotransformation inside cow tissues, the predicted concentrations of 14 polychlorinated biphenyls (PCBs) in milk were in good agreement with the observed data, especially for congeners known for their resistance to biotransformation (e.g., CB-138 and 153). In contrast, the predicted concentrations were clearly overestimated for congeners with high biotransformation susceptibilities.
Therefore data measured in milk and faeces were used to calculate the first-order-biotransformation rate constants in dairy cows. The PCB absorption efficiency observed for pasture conditionswas lower than that observed in the cowshed. The final version of the model included biotransformation and observed PCB absorption andwas able to predict PCB concentrations in cow milkwith mean differences between the predicted and measured data below \ub120% for most congener
Correlations between isospin dynamics and Intermediate Mass Fragments emission time scales: a probe for the symmetry energy in asymmetric nuclear matter
We show new data from the Ni+Sn and Ni+Sn
reactions studied in direct kinematics with the CHIMERA detector at INFN-LNS
and compared with the reverse kinematics reactions at the same incident beam
energy (35 A MeV). Analyzing the data with the method of relative velocity
correlations, fragments coming from statistical decay of an excited
projectile-like (PLF) or target-like (TLF) fragments are discriminated from the
ones coming from dynamical emission in the early stages of the reaction. By
comparing data of the reverse kinematics experiment with a stochastic mean
field (SMF) + GEMINI calculations our results show that observables from neck
fragmentation mechanism add valuable constraints on the density dependence of
symmetry energy. An indication is found for a moderately stiff symmetry energy
potential term of EOS.Comment: Talk given by E. De Filippo at the 11th International Conference on
Nucleus-Nucleus Collisions (NN2012), San Antonio, Texas, USA, May 27-June 1,
2012. To appear in the NN2012 Proceedings in Journal of Physics: Conference
Series (JPCS
The ASY-EOS experiment at GSI: investigating the symmetry energy at supra-saturation densities
The elliptic-flow ratio of neutrons with respect to protons in reactions of
neutron rich heavy-ions systems at intermediate energies has been proposed as
an observable sensitive to the strength of the symmetry term in the nuclear
Equation Of State (EOS) at supra-saturation densities. The recent results
obtained from the existing FOPI/LAND data for Au+Au collisions
at 400 MeV/nucleon in comparison with the UrQMD model allowed a first estimate
of the symmetry term of the EOS but suffer from a considerable statistical
uncertainty. In order to obtain an improved data set for Au+Au collisions and
to extend the study to other systems, a new experiment was carried out at the
GSI laboratory by the ASY-EOS collaboration in May 2011.Comment: Talk given by P. Russotto at the 11th International Conference on
Nucleus-Nucleus Collisions (NN2012), San Antonio, Texas, USA, May 27-June 1,
2012. To appear in the NN2012 Proceedings in Journal of Physics: Conference
Series (JPCS
Development and tests of a new prototype detector for the XAFS beamline at Elettra Synchrotron in Trieste
The XAFS beamline at Elettra Synchrotron in Trieste combines X-ray absorption
spectroscopy and X-ray diffraction to provide chemically specific structural
information of materials. It operates in the energy range 2.4-27 keV by using a
silicon double reflection Bragg monochromator. The fluorescence measurement is
performed in place of the absorption spectroscopy when the sample transparency
is too low for transmission measurements or the element to study is too diluted
in the sample. We report on the development and on the preliminary tests of a
new prototype detector based on Silicon Drift Detectors technology and the
SIRIO ultra low noise front-end ASIC. The new system will be able to reduce
drastically the time needed to perform fluorescence measurements, while keeping
a short dead time and maintaining an adequate energy resolution to perform
spectroscopy. The custom-made silicon sensor and the electronics are designed
specifically for the beamline requirements.Comment: Proceeding of the 6YRM 12th-14th Oct 2015 - L'Aquila (Italy).
Accepted for publication on Journal of Physics: Conference Serie
Projected Quasi-particle Perturbation theory
The BCS and/or HFB theories are extended by treating the effect of four
quasi-particle states perturbatively. The approach is tested on the pairing
hamiltonian, showing that it combines the advantage of standard perturbation
theory valid at low pairing strength and of non-perturbative approaches
breaking particle number valid at higher pairing strength. Including the
restoration of particle number, further improves the description of pairing
correlation. In the presented test, the agreement between the exact solution
and the combined perturbative + projection is almost perfect. The proposed
method scales friendly when the number of particles increases and provides a
simple alternative to other more complicated approaches
- …