292 research outputs found
Full-scale testing of low adhesion effects with small amounts of water in the wheel/rail interface
Low adhesion in the wheel/rail contact can be caused by small amounts of water combining with iron oxides. This happens in light rain or at dew point. In small-scale tests, ultra-low adhesion (≤0.05) has not been maintained. The aim here was to see if the mechanism could be realized at a larger scale. Sustained ultra-low adhesion was achieved when water was applied constantly to the wheel/rail contact at a rate of 25μL/s. In these conditions wear debris and oxide was clearly visible in the contact band. Creep force data has been generated that can now be used to inform wheel/rail contact models and multi-body dynamics simulations of train behaviour with a view to developing mitigation
Assessing the impact of small amounts of water and iron oxides on adhesion in the wheel/rail interface using High Pressure Torsion testing
A new High Pressure Torsion (HPT) set-up has been developed for assessing the effect of third body materials in the wheel/rail interface in a representative and controlled manner. In this study the technique has been used to investigate the effect of small amounts of water and iron oxides mixtures when subjected to different contact pressures. HPT tests showed reduction in adhesion relative to a dry contact when testing with small amounts of water and/or oxides, however sustained low adhesion (ÎĽ<0.05) was not produced. To aid interpretation of the results a model has been developed to explore the behavior encountered when testing with water and iron oxide mixtures. The model relates the shear properties of water and oxide mixtures (with increasing solid content) to a predicted adhesion. The model shows a narrow window of water to oxide fraction is required for reduced adhesion, particularly on rough surfaces, and this correlates with the behavior observed
Wheel-rail creep force model for predicting water induced low adhesion phenomena
A computationally efficient engineering model to predict adhesion in rolling contact in the presence of water is presented which may be implemented in multibody dynamics software or in braking models to study train performance and braking strategies. This model has been developed in a project funded by the Rail Safety and Standards Board (RSSB) and Network Rail. It is referred to as the water-induced low adhesion creep force (WILAC) model. The model covers a wide range of conditions from dry over damp to wet. Special emphasis is put on little amounts of water which can cause low adhesion without any oil or grease. Such conditions may be encountered in humid weather or at the onset of rain. The model is parameterised based on experimental results from a tram wheel test rig. Adhesion values as low as 0.06 are observed at high creep with only wear debris and little water present in the contact. The model results also agree with experimental data from locomotive tests in dry and wet conditions
Iron oxide and water paste rheology and its effect on low adhesion in the wheel/rail interface
The “wet-rail” phenomenon results in low adhesion between wheel and rail throughout the year, occurring transiently on a slightly wet, or drying railhead. It has been previously proposed that it is caused by a mixture of iron oxides and small amounts of water (from dew or precipitation) on the railhead that form a friction reducing paste. This paper outlines a novel combination of rheology, modelling and experimental work using a twin disc test rig to determine how the rheology of this iron oxide paste affects adhesion. The yield strength of different types of iron oxides, along with solid oxide fraction of the friction reducing paste, was assessed and used as an input into an “adhesion model” for assessing water and oxide suspensions. The rheological and modelling results were compared against very low adhesion recorded in twin disc experimental validation when simulating the wet-rail phenomenon
Clear-PEM: A PET imaging system dedicated to breast cancer diagnostics
The Clear-PEM scanner for positron emission mammography under development is described. The detector is based on pixelized LYSO crystals optically coupled to avalanche photodiodes and readout by a fast low-noise electronic system. A dedicated digital trigger (TGR) and data acquisition (DAQ) system is used for on-line selection of coincidence events with high efficiency, large bandwidth and small dead-time. A specialized gantry allows to perform exams of the breast and of the axilla. In this paper we present results of the measurement of detector modules that integrate the system under construction as well as the imaging performance estimated from Monte Carlo simulated data.http://www.sciencedirect.com/science/article/B6TJM-4M942B5-D/1/e8aea93baa1aeae3538ea200a5a5466
Virgo calibration and reconstruction of the gravitational wave strain during VSR1
Virgo is a kilometer-length interferometer for gravitational waves detection
located near Pisa. Its first science run, VSR1, occured from May to October
2007. The aims of the calibration are to measure the detector sensitivity and
to reconstruct the time series of the gravitational wave strain h(t). The
absolute length calibration is based on an original non-linear reconstruction
of the differential arm length variations in free swinging Michelson
configurations. It uses the laser wavelength as length standard. This method is
used to calibrate the frequency dependent response of the Virgo mirror
actuators and derive the detector in-loop response and sensitivity within ~5%.
The principle of the strain reconstruction is highlighted and the h(t)
systematic errors are estimated. A photon calibrator is used to check the sign
of h(t). The reconstructed h(t) during VSR1 is valid from 10 Hz up to 10 kHz
with systematic errors estimated to 6% in amplitude. The phase error is
estimated to be 70 mrad below 1.9 kHz and 6 micro-seconds above.Comment: 8 pages, 8 figures, proceedings of Amaldi 8 conference, to be
published in Journal of Physics Conference Series (JPCS). Second release:
correct typo
Sensitivity to Gravitational Waves from Compact Binary Coalescences Achieved during LIGO's Fifth and Virgo's First Science Run
We summarize the sensitivity achieved by the LIGO and Virgo gravitational
wave detectors for compact binary coalescence (CBC) searches during LIGO's
fifth science run and Virgo's first science run. We present noise spectral
density curves for each of the four detectors that operated during these
science runs which are representative of the typical performance achieved by
the detectors for CBC searches. These spectra are intended for release to the
public as a summary of detector performance for CBC searches during these
science runs.Comment: 12 pages, 5 figure
Fine-Tuning Cardiac Insulin-Like Growth Factor 1 Receptor Signaling to Promote Health and Longevity
Background: The insulin-like growth factor 1 (IGF1) pathway is a key regulator of cellular metabolism and aging. Although its inhibition promotes longevity across species, the effect of attenuated IGF1 signaling on cardiac aging remains controversial. Methods: We performed a lifelong study to assess cardiac health and lifespan in 2 cardiomyocyte-specific transgenic mouse models with enhanced versus reduced IGF1 receptor (IGF1R) signaling. Male mice with human IGF1R overexpression or dominant negative phosphoinositide 3-kinase mutation were examined at different life stages by echocardiography, invasive hemodynamics, and treadmill coupled to indirect calorimetry. In vitro assays included cardiac histology, mitochondrial respiration, ATP synthesis, autophagic flux, and targeted metabolome profiling, and immunoblots of key IGF1R downstream targets in mouse and human explanted failing and nonfailing hearts, as well. Results: Young mice with increased IGF1R signaling exhibited superior cardiac function that progressively declined with aging in an accelerated fashion compared with wild-type animals, resulting in heart failure and a reduced lifespan. In contrast, mice with low cardiac IGF1R signaling exhibited inferior cardiac function early in life, but superior cardiac performance during aging, and increased maximum lifespan, as well. Mechanistically, the late-life detrimental effects of IGF1R activation correlated with suppressed autophagic flux and impaired oxidative phosphorylation in the heart. Low IGF1R activity consistently improved myocardial bioenergetics and function of the aging heart in an autophagy-dependent manner. In humans, failing hearts, but not those with compensated hypertrophy, displayed exaggerated IGF1R expression and signaling activity. Conclusions: Our findings indicate that the relationship between IGF1R signaling and cardiac health is not linear, but rather biphasic. Hence, pharmacological inhibitors of the IGF1 pathway, albeit unsuitable for young individuals, might be worth considering in older adults
- …