558 research outputs found

    Microwave Antennas and Circuits Modeling Using Electromagnetic Field Simulator

    Get PDF
    Electromagnetic field simulators have become a widely used tool in a design process of microwave circuits and systems. A proper usage of electromagnetic (EM) field simulators allows substantial reduction of the design time providing reliable results. In such case the required parameters of the designed circuit can be reached even at the first manufactured prototype in spite of high complexity of the structure. However, EM simulation as a numerical process suffers from systematic and random errors similar to measurement using real equipment. Thus the setting of the EM-field simulator such as a frequency range, mesh properties, usage of PEC and PMC walls etc. has to be done with the highest attention and the simulation results have to be always verified using well-established techniques. The aim of the paper is to demonstrate the selected capability of EM-field simulators with a few examples of antenna and circuit modeling. Also an issue of reliability and simulation errors will be discussed

    State-space average modelling of converters with parasitics and storage-time modulation

    Get PDF
    The State-Space Averaging approach to modelling switching converter power stages is used to extend the analytical descriptions of the buck, boost, buck-boost, and Cuk converters to included the effects of all parasitic resistances and transistor storage-time modulation. The analysis reveals for the first time a new and unexpected term in the line to ouput response of the Cuk converter. The new term contains a right half-plane zero produced by the energy transfer capacitance in combination with the duty-ratio-weighted sum of the on-resistances of the transistor and diode plus a non-dissipative ac resistance term due to transistor storage-time modulation. The conventional circuit model of the converter is modified to include the effects of the new term. The improved model permits an eas physical interpretation of the new zero, which has been observed only the in Cuk converter. An extended analysis of storage-time modulation in bipolar transistor switches shows that the ac small-signal performance of a switching converter is highly dependent on the nature of the base drive. It is demonstrated that storage-time modulation in conjunction with a proportional base drive can produce instability in switching converters, even open-loop. The results of these analyses are verified experimentally and their impacts on practical converters are discussed

    Microprocessor-Controlled Digital Shunt Regulator

    Get PDF
    A new approach to the design of power systems is presented in which a microprocessor is used as a controller for a digital shunt regulator (DSR). This approach meets the demands of future space and ground missions, i.e., high efficiency, high reliability, low weight, low volume, increased flexibility, and less development time. This approach responds to future demands by permitting real-time modification of system parameters for system optimization. This feature is especially important in the event of an anomaly. As the microprocessor need not be dedicated to the DSR, it can simultaneously be used for battery management and for charge regulator/discharge regulator control. This approach also reduces the component count, simplifies assembly and testing of the unit, results in significant time saving, and increases the reliability

    Investigation of β-carotene–gelatin composite particles with a multiwavelength UV/vis detector for the analytical ultracentrifuge

    Get PDF
    A multiwavelength UV/vis detector for the analytical ultracentrifuge (MWL-AUC) has been developed recently. In this work, β-carotene–gelatin composite particles are investigated with MWL-AUC. Band centrifugation with a Vinograd cell is used to ensure maximum sample separation. Spectral changes of the system are observed in dependence of the sedimentation coefficient and are attributed to a previously unknown inhomogeneity of the β-carotene chemical composition with both H- and J-aggregates coexisting in a mixture. In addition, our data suggest that pure H- and J-aggregates exist in a particle while their relative concentrations in a mixture determine the color characteristics of the sample. The unique abilities and properties of MWL-AUC include sedimentation coefficient distributions for all possible wavelengths, full UV/vis spectra of each different species in the mixture and 3D movies of the sedimentation process. These properties significantly extend the scope of the analytical ultracentrifuge technique and show that complex biopolymer multicomponent mixtures can be resolved into their individual species

    Tests of the Equivalence Principle with Neutral Kaons

    Get PDF
    We test the Principle of Equivalence for particles and antiparticles, using CPLEAR data on tagged K0 and K0bar decays into pi^+ pi^-. For the first time, we search for possible annual, monthly and diurnal modulations of the observables |eta_{+-}| and phi_{+-}, that could be correlated with variations in astrophysical potentials. Within the accuracy of CPLEAR, the measured values of |eta_{+-}| and phi_{+-} are found not to be correlated with changes of the gravitational potential. We analyze data assuming effective scalar, vector and tensor interactions, and we conclude that the Principle of Equivalence between particles and antiparticles holds to a level of 6.5, 4.3 and 1.8 x 10^{-9}, respectively, for scalar, vector and tensor potentials originating from the Sun with a range much greater than the distance Earth-Sun. We also study energy-dependent effects that might arise from vector or tensor interactions. Finally, we compile upper limits on the gravitational coupling difference between K0 and K0bar as a function of the scalar, vector and tensor interaction range.Comment: 15 pages latex 2e, five figures, one style file (cernart.csl) incorporate

    Номінація частин руки в говірці села Невгоди Овруцького району Житомирської області

    Get PDF
    У статті розглянуто лексеми на позначення частин руки в сучасній середньополіській говірці, зокрема проаналізовано їхню семантику та мотивацію.В статье рассматриваются лексемы, обозначающие части руки, в современном среднеполесском говоре, а именно проанализирована их семантика и мотивация.The article deals with lexemes on designations of parts of the manuscript in the middle-polissya dialect. Their semantics and motivation are also analyzed

    Test of CPT Symmetry and Quantum Mechanics with Experimental data from CPLEAR

    Full text link
    We use fits to recent published CPLEAR data on neutral kaon decays to π+π\pi^+\pi^- and πeν\pi e\nu to constrain the CPT--violation parameters appearing in a formulation of the neutral kaon system as an open quantum-mechanical system. The obtained upper limits of the CPT--violation parameters are approaching the range suggested by certain ideas concerning quantum gravity.Comment: 9 pages of uuencoded postscript (includes 3 figures

    The CPLEAR Electromagnetic Calorimeter

    Get PDF
    A large-acceptance lead/gas sampling electromagnetic calorimeter (ECAL) was constructed for the CPLEAR experiment to detect photons from decays of π0\pi^0s with momentum pπ0800p_{\pi^0} \le 800 MeV/c/c. The main purpose of the ECAL is to determine the decay vertex of neutral-kaon decays \ko \rightarrow \pi^0\pi^0 \rightarrow 4 \gamma and \ko \rightarrow \pi^0\pi^0\pi^0 \rightarrow 6 \gamma. This requires a position-sensitive photon detector with high spatial granularity in rr-, φ\varphi-, and zz-coordinates. The ECAL --- a barrel without end-caps located inside a magnetic field of 0.44 T --- consists of 18 identical concentric layers. Each layer of 1/31/3 radiation length (X0{_0}) contains a converter plate followed by small cross-section high-gain tubes of 2640 mm active length which are sandwiched by passive pick-up strip plates. The ECAL, with a total of 66 X0{_0}, has an energy resolution of σ(E)/E13%/E(GeV)\sigma (E)/E \approx 13\% / \sqrt{E(\mathrm{GeV})} and a position resolution of 4.5 mm for the shower foot. The shower topology allows separation of electrons from pions. The design, construction, read-out electronics, and performance of the detector are described
    corecore