341 research outputs found

    Proximal ulna stress fracture and stress reaction of the proximal radius associated with the use of crutches: a case report and literature review

    Get PDF
    We report a case of complete stress fracture of the ulna and stress reaction of the radius resulting from the use of crutches in an overweight patient with severe lower extremity arthritis. Plain radiograph showed an undisplaced complete fracture of the proximal metaphysis of the ulna. Magnetic resonance imaging (MRI) was performed to exclude a pathological cause in view of the unusual fracture site, which confirmed the plain radiographic findings and additionally demonstrated a stress reaction in the proximal radius. There are three cases of stress fracture of the ulnar diaphysis resulting from the use of crutches reported previously in the English literature and a further case of bilaterally symmetrical ulnar diaphysial fracture reported in the Danish literature. We report the first case of ulnar metaphysis stress fracture with concomitant stress reaction of the radius

    Routine MRI findings of the asymptomatic foot in diabetic patients with unilateral Charcot foot

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Imaging studies of bones in patients with sensory deficits are scarce.</p> <p>Aim</p> <p>To investigate bone MR images of the lower limb in diabetic patients with severe sensory polyneuropathy, and in control subjects without sensory deficits.</p> <p>Methods</p> <p>Routine T1 weighted and T2-fat-suppressed-STIR-sequences without contrast media were performed of the asymptomatic foot in 10 diabetic patients with polyneuropathy and unilateral inactive Charcot foot, and in 10 matched and 10 younger, non-obese unmatched control subjects. Simultaneously, a Gadolinium containing phantom was also assessed for reference. T1 weighted signal intensity (SI) was recorded at representative regions of interest at the peritendineal soft tissue, the tibia, the calcaneus, and at the phantom. Any abnormal skeletal morphology was also recorded.</p> <p>Results</p> <p>Mean SI at the soft tissue, the calcaneus, and the tibia, respectively, was 105%, 105% and 84% of that at the phantom in the matched and unmatched control subjects, compared to 102% (soft tissue), 112% (calcaneus) and 64% (tibia) in the patients; differences of tibia vs. calcaneus or soft tissue were highly significant (p < 0.005). SI at the tibia was lower in the patients than in control subjects (p < 0.05). Occult traumatic skeletal lesions were found in 8 of the 10 asymptomatic diabetic feet (none in the control feet).</p> <p>Conclusion</p> <p>MR imaging did not reveal grossly abnormal bone marrow signalling in the limbs with severe sensory polyneuropathy, but occult sequelae of previous traumatic injuries.</p

    Magnetic resonance imaging of anterior cruciate ligament rupture

    Get PDF
    BACKGROUND: Magnetic resonance (MR) imaging is a useful diagnostic tool for the assessment of knee joint injury. Anterior cruciate ligament repair is a commonly performed orthopaedic procedure. This paper examines the concordance between MR imaging and arthroscopic findings. METHODS: Between February, 1996 and February, 1998, 48 patients who underwent magnetic resonance (MR) imaging of the knee were reported to have complete tears of the anterior cruciate ligament (ACL). Of the 48 patients, 36 were male, and 12 female. The average age was 27 years (range: 15 to 45). Operative reconstruction using a patellar bone-tendon-bone autograft was arranged for each patient, and an arthroscopic examination was performed to confirm the diagnosis immediately prior to reconstructive surgery. RESULTS: In 16 of the 48 patients, reconstructive surgery was cancelled when incomplete lesions were noted during arthroscopy, making reconstructive surgery unnecessary. The remaining 32 patients were found to have complete tears of the ACL, and therefore underwent reconstructive surgery. Using arthroscopy as an independent, reliable reference standard for ACL tear diagnosis, the reliability of MR imaging was evaluated. The true positive rate for complete ACL tear diagnosis with MR imaging was 67%, making the possibility of a false-positive report of "complete ACL tear" inevitable with MR imaging. CONCLUSIONS: Since conservative treatment is sufficient for incomplete ACL tears, the decision to undertake ACL reconstruction should not be based on MR findings alone

    Magnetic resonance imaging, magnetic resonance arthrography and ultrasonography for assessing rotator cuff tears in people with shoulder pain for whom surgery is being considered

    Get PDF
    Background Shoulder pain is a very common symptom. Disorders of the rotator cuff tendons due to wear or tear are among the most common causes of shoulder pain and disability. Magnetic resonance imaging (MRI), magnetic resonance arthrography (MRA) and ultrasound (US) are increasingly being used to assess the presence and size of rotator cuff tears to assist in planning surgical treatment. It is not known whether one imaging method is superior to any of the others.Objectives To compare the diagnostic test accuracy of MRI, MRA and US for detecting any rotator cuff tears (i.e. partial or full thickness) in people with suspected rotator cuff tears for whom surgery is being considered.Search methods We searched the Cochrane Register of Diagnostic Test Accuracy Studies, MEDLINE, EMBASE, and LILACS from inception to February 2011. We also searched trial registers, conference proceedings and reference lists of articles to identify additional studies. No language or publication restrictions were applied.Selection criteria We included all prospective diagnostic accuracy studies that assessed MRI, MRA or US against arthroscopy or open surgery as the reference standard, in people suspected of having a partial or full thickness rotator cuff tear. We excluded studies that selected a healthy control group, or participants who had been previously diagnosed with other specific causes of shoulder pain such as osteoarthritis or rheumatoid arthritis. Studies with an excessively long period (a year or longer) between the index and reference tests were also excluded.Data collection and analysis Two review authors independently extracted data on study characteristics and results of included studies, and performed quality assessment according to QUADAS criteria. Our unit of analysis was the shoulder. for each test, estimates of sensitivity and specificity from each study were plotted in ROC space and forest plots were constructed for visual examination of variation in test accuracy. Meta-analyses were performed using the bivariate model to produce summary estimates of sensitivity and specificity. We were unable to formally investigate potential sources of heterogeneity because of the small number of studies.Main results We included 20 studies of people with suspected rotator cuff tears (1147 shoulders), of which six evaluated MRI and US (252 shoulders), or MRA and US (127 shoulders) in the same people. Many studies had design flaws, with the potential for bias, thus limiting the reliability of their findings. Overall, the methodological quality of the studies was judged to be low or unclear. for each test, we observed considerable heterogeneity in study results, especially between studies that evaluated US for the detection of full thickness tears and studies that evaluated MRA for the detection of partial thickness tears. the criteria for a positive diagnostic test (index tests and reference standard) varied between studies.Meta-analyses were not possible for studies that assessed MRA for detection of any rotator cuff tears or partial thickness tears. We found no statistically significant differences in sensitivity or specificity between MRI and US for detecting any rotator cuff tears (P = 0.13), or for detecting partial thickness tears (P = 1.0). Similarly, for the comparison between MRI, MRA and US for detecting full thickness tears, there was no statistically significant difference in diagnostic performance (P = 0.7). for any rotator cuff tears, the summary sensitivity and specificity were 98% (95% CI 92% to 99%) and 79% (95% CI 68% to 87%) respectively for MRI (6 studies, 347 shoulders), and 91% (95% CI 83% to 95%) and 85% (95% CI 74% to 92%) respectively for US (13 studies, 854 shoulders). for full thickness tears, the summary sensitivity and specificity were 94% (95% CI 85% to 98%) and 93% (95% CI 83% to 97%) respectively for MRI (7 studies, 368 shoulders); 94% (95% CI 80% to 98%) and 92% (95% CI 83% to 97%) respectively for MRA (3 studies, 183 shoulders); and 92% (95% CI 82% to 96%) and 93% (95% CI 81% to 97%) respectively for US (10 studies, 729 shoulders).Because few studies were direct head-to-head comparisons, we could not perform meta-analyses restricted to these studies. the test comparisons for each of the three classifications of the target condition were therefore based on indirect comparisons which may be prone to bias due to confounding.Authors' conclusions MRI, MRA and US have good diagnostic accuracy and any of these tests could equally be used for detection of full thickness tears in people with shoulder pain for whom surgery is being considered. the diagnostic performance of MRI and US may be similar for detection of any rotator cuff tears. However, both MRI and US may have poor sensitivity for detecting partial thickness tears, and the sensitivity of US may be much lower than that of MRI. the strength of evidence for all test comparisons is limited because most studies were small, heterogeneous and methodologically flawed, and there were few comparative studies. Well designed studies that directly compare MRI, MRA and US for detection of rotator cuff tears are needed.Universidade Federal de São Paulo, BrazilParker Institute, DenmarkOak FoundationTeesside University, UKUniversidade Federal de São Paulo, Dept Orthopaed & Traumatol, BR-04038032 São Paulo, BrazilMonash Univ, Sch Publ Hlth & Prevent Med, Dept Epidemiol & Prevent Med, Monash Dept Clin Epidemiol,Cabrini Hosp, Malvern, AustraliaUniv Birmingham, Birmingham, W Midlands, EnglandUniv Teesside, Hlth & Social Care Inst, Middlesbrough, Cleveland, EnglandUniversidade Federal de São Paulo, Dept Orthopaed & Traumatol, BR-04038032 São Paulo, BrazilWeb of Scienc

    Case Reports1. A Late Presentation of Loeys-Dietz Syndrome: Beware of TGFβ Receptor Mutations in Benign Joint Hypermobility

    Get PDF
    Background: Thoracic aortic aneurysms (TAA) and dissections are not uncommon causes of sudden death in young adults. Loeys-Dietz syndrome (LDS) is a rare, recently described, autosomal dominant, connective tissue disease characterized by aggressive arterial aneurysms, resulting from mutations in the transforming growth factor beta (TGFβ) receptor genes TGFBR1 and TGFBR2. Mean age at death is 26.1 years, most often due to aortic dissection. We report an unusually late presentation of LDS, diagnosed following elective surgery in a female with a long history of joint hypermobility. Methods: A 51-year-old Caucasian lady complained of chest pain and headache following a dural leak from spinal anaesthesia for an elective ankle arthroscopy. CT scan and echocardiography demonstrated a dilated aortic root and significant aortic regurgitation. MRA demonstrated aortic tortuosity, an infrarenal aortic aneurysm and aneurysms in the left renal and right internal mammary arteries. She underwent aortic root repair and aortic valve replacement. She had a background of long-standing joint pains secondary to hypermobility, easy bruising, unusual fracture susceptibility and mild bronchiectasis. She had one healthy child age 32, after which she suffered a uterine prolapse. Examination revealed mild Marfanoid features. Uvula, skin and ophthalmological examination was normal. Results: Fibrillin-1 testing for Marfan syndrome (MFS) was negative. Detection of a c.1270G > C (p.Gly424Arg) TGFBR2 mutation confirmed the diagnosis of LDS. Losartan was started for vascular protection. Conclusions: LDS is a severe inherited vasculopathy that usually presents in childhood. It is characterized by aortic root dilatation and ascending aneurysms. There is a higher risk of aortic dissection compared with MFS. Clinical features overlap with MFS and Ehlers Danlos syndrome Type IV, but differentiating dysmorphogenic features include ocular hypertelorism, bifid uvula and cleft palate. Echocardiography and MRA or CT scanning from head to pelvis is recommended to establish the extent of vascular involvement. Management involves early surgical intervention, including early valve-sparing aortic root replacement, genetic counselling and close monitoring in pregnancy. Despite being caused by loss of function mutations in either TGFβ receptor, paradoxical activation of TGFβ signalling is seen, suggesting that TGFβ antagonism may confer disease modifying effects similar to those observed in MFS. TGFβ antagonism can be achieved with angiotensin antagonists, such as Losartan, which is able to delay aortic aneurysm development in preclinical models and in patients with MFS. Our case emphasizes the importance of timely recognition of vasculopathy syndromes in patients with hypermobility and the need for early surgical intervention. It also highlights their heterogeneity and the potential for late presentation. Disclosures: The authors have declared no conflicts of interes
    • …
    corecore