592 research outputs found
Investigation of the Protonation Site in the Dialanine Peptide by Infrared Multiphoton Dissociation Spectroscopy
Protonated dialanine cations have been isolated in a Fourier transform ion cyclotron resonance mass-spectrometer (FT-ICR-MS) and subjected to infrared multiphoton dissociation (IRMPD) at the free electron laser facility CLIO in Orsay (France). The spectral dependence of the IR induced fragmentation pattern in the mid-infrared region (800-2000 cm-1) is interpreted with the help of structure and vibrational spectrum calculations of the different protonated conformers. This comparison allows for the assignment of the proton on the terminal amino group, as the most favourable proton site, the neighbouring amide bond being in the trans conformation
El resum: més del mateix
Abstract not availabl
Stump closure reinforcement with absorbable fibrin collagen sealant sponge (TachoSil®) does not prevent pancreatic fistula after distal pancreatectomy: the FIABLE* multicenter controlled randomized study
International audienceBackground - The aim of this study is to evaluate the effectiveness of TachoSil sponge on distal pancreatectomy remnant stump in reducing the rate and severity of postoperative pancreatic fistula (POPF). Methods - All consecutive patients requiring distal pancreatectomy were randomized in 45 centers. The principal end point was onset of "clinically relevant" POPF. Univariate and multivariate analyses were searched for predictive factors. Results - Of the 270 patients randomized (134 with TachoSil; 136 without), 150 (55.6%) patients sustained a POPF [74 clinically relevant and 76 clinically silent (27.4% and 28.1%), respectively]: no statistically significant difference was found between patients sustaining clinically relevant POPF [41 (30.6%) with vs 33 (24.3%) without TachoSil (P = .276)], or overall POPF [73 (54.5%) with vs 77 (56.6%) without TachoSil, (P = .807)], but there were more clinically relevant POPF after hand-sewn (32.3%) versus mechanical closure (19.8%) (P = .025) and, in case of splenic preservation, after splenic vessel ligation (15/32, 46.9%) versus vascular preservation (17/72, 23.6%) (P = .024). Hand-sewn pancreatic remnant closure (P = .023) and splenic vessel ligation in splenic preservation (P = .035) were independent predictive factors for the onset of clinically relevant POPF. Conclusion - TachoSil sponge reinforcement of the proximal remnant after distal pancreatectomy reduced neither the rate nor the severity of POPF
Combined Immunoglobulin Free Light Chains Are Novel Predictors of Cardiovascular Events in Patients With Abdominal Aortic Aneurysm.
Abdominal aortic aneurysm (AAA) is characterised by the presence of B cells and immunoglobulins in the aortic wall, mainly in the adventitia. Kappa (κ) and lambda (λ) free light chains (FLCs) are produced from B cells during immunoglobulin synthesis. This study investigated the presence and prognostic value of combined FLCs (cFLCs or summed κ and λ) in patients with AAA.
cFLCs were analysed by a turbidimetric specific assay in tissue conditioned media from AAA samples (n = 34) compared with healthy aortas (n = 34) from France and in plasma samples from patients with AAA (n = 434) and age matched controls (n = 104) selected from the Viborg Vascular (VIVA) AAA screening trial in Denmark. t test, logistic regression, and Cox regression were used to test whether plasma cFLCs serve as a marker for AAA presence and whether cFLCs were predictive of death, major adverse cardiovascular events (MACE), or major adverse lower limb events (MALE).
Increased cFLC levels were detected in the AAA adventitial layer compared with the AAA medial layer and healthy media layer (13.65 ± 3.17 vs. 6.57 ± 1.01 vs. 0.49 ± 0.09 mg/L, respectively, p < .050). The upper tertile of plasma cFLCs was independently associated with AAA presence after correcting for confounders (odds ratio [OR] 7.596, 95% confidence intervals [CI] 3.117 - 18.513; p < .001). Of 434 patients with AAA, 89 (20.5%) died, 104 (24.0%) suffered MACE, and 63 (14.5%) suffered MALE, during a five year follow up. In univariable analysis, the cFLC upper tertile was associated with a higher risk of death, MACE, and MALE (p < .001 for all). After adjustment for confounders, cFLCs remained an independent predictor of all cause mortality (hazard ratio [HR] 4.310, 95% CI 2.157 - 8.609; p < .001), MACE (HR 2.153, 95% CI 1.218 - 3.804; p = .008), or MALE (HR 3.442, 95% CI 1.548 - 7.652; p = .002) for those in the upper tertile.
Increased cFLCs are observed in adventitial tissue of patients with AAA, indicating local activation of B cells. Plasma cFLC levels are an independent predictor of death, MACE, and MALE in patients with AAA.This study was funded by the Spanish MINECO (PID2019-
106814RB-I00 and PGC2018-097019-B-I00), la Caixa
Foundation (HR17-00247), CAM (S2017/BMD-3673), and
Fondo de Investigaciones Sanitarias ISCiii-FEDER (PI19/
00128).S
Bias correction of OMI HCHO columns based on FTIR and aircraft measurements and impact on top-down emission estimates
Spaceborne formaldehyde (HCHO) measurements constitute an excellent proxy for the sources of non-methane volatile organic compounds (NMVOCs). Past studies suggested substantial overestimations of NMVOC emissions in state-of-the-art inventories over major source regions. Here, the QA4ECV (Quality Assurance for Essential Climate Variables) retrieval of HCHO columns from OMI (Ozone Monitoring Instrument) is evaluated against (1) FTIR (Fourier-transform infrared) column observations at 26 stations worldwide and (2) aircraft in situ HCHO concentration measurements from campaigns conducted over the USA during 2012–2013. Both validation exercises show that OMI underestimates high columns and overestimates low columns. The linear regression of OMI and aircraft-based columns gives Ω=0,651 Ω+2,95 x 10, molec. cm , with Ω and Ω the OMI and aircraft-derived vertical columns, whereas the regression of OMI and FTIR data gives Ω= 6,59 Ω + 2.02 x 10, molec. cm . Inverse modelling of NMVOC emissions with a global model based on OMI columns corrected for biases based on those relationships leads to much-improved agreement against FTIR data and HCHO concentrations from 11 aircraft campaigns. The optimized global isoprene emissions ( 445 Tgyr) are 25 % higher than those obtained without bias correction. The optimized isoprene emissions bear both striking similarities and differences with recently published emissions based on spaceborne isoprene columns from the CrIS (Cross-track Infrared Sounder) sensor. Although the interannual variability of OMI HCHO columns is well understood over regions where biogenic emissions are dominant, and the HCHO trends over China and India clearly reflect anthropogenic emission changes, the observed HCHO decline over the southeastern USA remains imperfectly elucidated
TROPOMI–Sentinel-5 Precursor formaldehyde validation using an extensive network of ground-based Fourier-transform infrared stations
TROPOMI (the TROPOspheric Monitoring Instrument), on board the Sentinel-5 Precursor (S5P) satellite, has been monitoring the Earth\u27s atmosphere since October 2017 with an unprecedented horizontal resolution (initially 7 km×3.5 km, upgraded to 5.5 km×3.5 km in August 2019). Monitoring air quality is one of the main objectives of TROPOMI; it obtains measurements of important pollutants such as nitrogen dioxide, carbon monoxide, and formaldehyde (HCHO). In this paper we assess the quality of the latest HCHO TROPOMI products versions 1.1.(5-7), using ground-based solar-absorption FTIR (Fourier-transform infrared) measurements of HCHO from 25 stations around the world, including high-, mid-, and low-latitude sites. Most of these stations are part of the Network for the Detection of Atmospheric Composition Change (NDACC), and they provide a wide range of observation conditions, from very clean remote sites to those with high HCHO levels from anthropogenic or biogenic emissions. The ground-based HCHO retrieval settings have been optimized and harmonized at all the stations, ensuring a consistent validation among the sites.
In this validation work, we first assess the accuracy of TROPOMI HCHO tropospheric columns using the median of the relative differences between TROPOMI and FTIR ground-based data (BIAS). The pre-launch accuracy requirements of TROPOMI HCHO are 40 %–80 %. We observe that these requirements are well reached, with the BIAS found below 80 % at all the sites and below 40 % at 20 of the 25 sites. The provided TROPOMI systematic uncertainties are well in agreement with the observed biases at most of the stations except for the highest-HCHO-level site, where it is found to be underestimated. We find that while the BIAS has no latitudinal dependence, it is dependent on the HCHO concentration levels: an overestimation (+26±5 %) of TROPOMI is observed for very low HCHO levels (8.0×10 molec. cm). This demonstrates the great value of such a harmonized network covering a wide range of concentration levels, the sites with high HCHO concentrations being crucial for the determination of the satellite bias in the regions of emissions and the clean sites allowing a small TROPOMI offset to be determined. The wide range of sampled HCHO levels within the network allows the robust determination of the significant constant and proportional TROPOMI HCHO biases (TROPOMI =+1.10±0.05 ×10+0.64±0.03 × FTIR; in molecules per square centimetre).
Second, the precision of TROPOMI HCHO data is estimated by the median absolute deviation (MAD) of the relative differences between TROPOMI and FTIR ground-based data. The clean sites are especially useful for minimizing a possible additional collocation error. The precision requirement of 1.2×10 molec. cm for a single pixel is reached at most of the clean sites, where it is found that the TROPOMI precision can even be 2 times better (0.5–0.8×10 molec. cm for a single pixel). However, we find that the provided TROPOMI random uncertainties may be underestimated by a factor of 1.6 (for clean sites) to 2.3 (for high HCHO levels). The correlation is very good between TROPOMI and FTIR data (R=0.88 for 3 h mean coincidences; R=0.91 for monthly means coincidences). Using about 17 months of data (from May 2018 to September 2019), we show that the TROPOMI seasonal variability is in very good agreement at all of the FTIR sites.
The FTIR network demonstrates the very good quality of the TROPOMI HCHO products, which is well within the pre-launch requirements for both accuracy and precision. This paper makes suggestions for the refinement of the TROPOMI random uncertainty budget and TROPOMI quality assurance values for a better filtering of the remaining outliers
NDACC harmonized formaldehyde time-series from 21 FTIR stations covering a wide range of column abundances
Among the more than 20 ground-based FTIR (Fourier transform infrared) stations currently operating around the globe, only a few have provided formaldehyde (HCHO) total column time series until now. Although several independent studies have shown that the FTIR measurements can provide formaldehyde total columns with good precision, the spatial coverage has not been optimal for providing good diagnostics for satellite or model validation. Furthermore, these past studies used different retrieval settings, and biases as large as 50 % can be observed in the HCHO total columns depending on these retrieval choices, which is also a weakness for validation studies combining data from different ground-based stations.
For the present work, the HCHO retrieval settings have been optimized based on experience gained from past studies and have been applied consistently at the 21 participating stations. Most of them are either part of the Network for the Detection of Atmospheric Composition Change (NDACC) or under consideration for membership. We provide the harmonized settings and a characterization of the HCHO FTIR products. Depending on the station, the total systematic and random uncertainties of an individual HCHO total column measurement lie between 12 % and 27 % and between 1 and 11×1014 molec cm−2, respectively. The median values among all stations are 13 % and 2.9×1014 molec cm−2 for the total systematic and random uncertainties.
This unprecedented harmonized formaldehyde data set from 21 ground-based FTIR stations is presented and its comparison with a global chemistry transport model shows consistency in absolute values as well as in seasonal cycles. The network covers very different concentration levels of formaldehyde, from very clean levels at the limit of detection (few 1013 molec cm−2) to highly polluted levels (7×1016 molec cm−2). Because the measurements can be made at any time during daylight, the diurnal cycle can be observed and is found to be significant at many stations. These HCHO time series, some of them starting in the 1990s, are crucial for past and present satellite validation and will be extended in the coming years for the next generation of satellite missions.This study has been supported by the ESA
PRODEX project TROVA (2016–2018) funded by the Belgian
Science Policy Office (Belspo)
NDACC harmonized formaldehyde time series from 21 FTIR stations covering a wide range of column abundances
Among the more than 20 ground-based FTIR (Fourier transform infrared) stations currently operating around the globe, only a few have provided formaldehyde (HCHO) total column time series until now. Although several independent studies have shown that the FTIR measurements can provide formaldehyde total columns with good precision, the spatial coverage has not been optimal for providing good diagnostics for satellite or model validation. Furthermore, these past studies used different retrieval settings, and biases as large as 50% can be observed in the HCHO total columns depending on these retrieval choices, which is also a weakness for validation studies combining data from different ground-based stations. For the present work, the HCHO retrieval settings have been optimized based on experience gained from past studies and have been applied consistently at the 21 participating stations. Most of them are either part of the Network for the Detection of Atmospheric Composition Change (NDACC) or under consideration for membership. We provide the harmonized settings and a characterization of the HCHO FTIR products. Depending on the station, the total systematic and random uncertainties of an individual HCHO total column measurement lie between 12% and 27% and between 1 and 11x1014 moleccm-2, respectively. The median values among all stations are 13% and 2.9x1014 moleccm-2 for the total systematic and random uncertainties. This unprecedented harmonized formaldehyde data set from 21 ground-based FTIR stations is presented and its comparison with a global chemistry transport model shows consistency in absolute values as well as in seasonal cycles. The network covers very different concentration levels of formaldehyde, from very clean levels at the limit of detection (few 1013moleccm-2) to highly polluted levels (7x1016moleccm-2). Because the measurements can be made at any time during daylight, the diurnal cycle can be observed and is found to be significant at many stations. These HCHO time series, some of them starting in the 1990s, are crucial for past and present satellite validation and will be extended in the coming years for the next generation of satellite missions
- …