1,015 research outputs found

    Erosion wear of glass fibre reinforced vinyl ester

    Get PDF
    This study evaluates the slurry-erosion wear of glass fibre reinforced vinyl ester composites (VE-FRP) using a high speed slurry-pot type wear tester. The wear rates of VE-FRP were compared using different abrasives, namely quartz, chromite, copper ore, zinc concentrate, and tailings. Furthermore, the effect of abrasive particle size and slurry concentration on the VE-FRP wear was studied. The erosion wear results of VE-FRP were compared to natural rubber (NR) and bromobutyl rubber (BIIR) as well as to few common thermoplastics, such as polypropylene (PP) and polyvinyl chloride (PVC). Moreover, the failure characteristics of VE-FRP were analyzed. The results demonstrated that coarse quartz produced the largest wear rates on VE-FRP samples, while the zinc concentrate showed the lowest wear. Minor changes in the abrasive particle size had no effect on the wear results, only when the particle size was markedly raised, the wear started to increase. When comparing the wear rates of different materials, it was concluded that with all abrasive types, tested rubbers and thermoplastics had lower wear rates than VE-FRP

    Surface reconstruction of wear in carpets by using a wavelet edge detector

    Get PDF
    Carpet manufacturers have wear labels assigned to their products by human experts who evaluate carpet samples subjected to accelerated wear in a test device. There is considerable industrial and academic interest in going from human to automated evaluation, which should be less cumbersome and more objective. In this paper, we present image analysis research on videos of carpet surfaces scanned with a 3D laser. The purpose is obtaining good depth Images for an automated system that should have a high percentage of correct assessments for a wide variety of carpets. The innovation is the use of a wavelet edge detector to obtain a more continuously defined surface shape. The evaluation is based on how well the algorithms allow a good linear ranking and a good discriminance of consecutive wear labels. The results show an improved linear ranking for most carpet types, for two carpet types the results are quite significant

    Lymphatic endothelium stimulates melanoma metastasis and invasion via MMP14-dependent Notch3 and b1-integrin activation

    Get PDF
    Lymphatic invasion and lymph node metastasis correlate with poor clinical outcome in melanoma. However, the mechanisms of lymphatic dissemination in distant metastasis remain incompletely understood. We show here that exposure of expansively growing human WM852 melanoma cells, but not singly invasive Bowes cells, to lymphatic endothelial cells (LEC) in 3D co-culture facilitates melanoma distant organ metastasis in mice. To dissect the underlying molecular mechanisms, we established LEC co-cultures with different melanoma cells originating from primary tumors or metastases. Notably, the expansively growing metastatic melanoma cells adopted an invasively sprouting phenotype in 3D matrix that was dependent on MMP14, Notch3 and β1-integrin. Unexpectedly, MMP14 was necessary for LEC-induced Notch3 induction and coincident β1-integrin activation. Moreover, MMP14 and Notch3 were required for LEC-mediated metastasis of zebrafish xenografts. This study uncovers a unique mechanism whereby LEC contact promotes melanoma metastasis by inducing a reversible switch from 3D growth to invasively sprouting cell phenotype

    Calculated beam quality correction factors for ionization chambers in MV photon beams

    Get PDF
    The beam quality correction factor, , which corrects for the difference in the ionization chamber response between the reference and clinical beam quality, is an integral part of radiation therapy dosimetry. The uncertainty of is one of the most significant sources of uncertainty in the dose determination. To improve the accuracy of available data, four partners calculated factors for 10 ionization chamber models in linear accelerator beams with accelerator voltages ranging from 6 MV to 25 MV, including flattening-filter-free (FFF) beams. The software used in the calculations were EGSnrc and PENELOPE, and the ICRU report 90 cross section data for water and graphite were included in the simulations. Volume averaging correction factors were calculated to correct for the dose averaging in the chamber cavities. A comparison calculation between partners showed a good agreement, as did comparison with literature. The values from TRS-398 were higher than our values for each chamber where data was available. The values for the FFF beams did not follow the same , relation as beams with flattening filter (values for 10 MV FFF beams were below fits made to other data on average by 0.3%), although our FFF sources were only for Varian linacs.Peer reviewe

    Effect of Donor Simvastatin Treatment on Gene Expression Profiles in Human Cardiac Allografts during Ischemia-Reperfusion Injury

    Get PDF
    Purpose Numerous studies have shown that statin therapy initiated early after heart transplantation has beneficial effects on the development of cardiac allograft vasculopathy. Recently, we were able to show in a randomized clinical trial that simvastatin treatment of brain-dead donors conditions the heart transplant to withstand ischemia-reperfusion injury and to reduce the need for rejection treatments early after transplantation. In this study, we analyzed myocardial gene expression profiles in cardiac allografts after donor simvastatin treatment. Methods 84 heart transplant donors received 80 mg of simvastatin via nasogastric tube (n=42), or no treatment (n=42) in a prospective, double-blinded randomized controlled trial. Transmural Tru-Cut biopsies were taken from the apex of left ventricle of the donor heart immediately before reperfusion and 1 hour after reperfusion. 20 heart biopsies from donors without treatment and 20 heart biopsies from donors with simvastatin treatment will be analyzed with RNA sequencing. Results The preliminary analysis of RNA sequencing data from myocardial biopsies revealed altogether 137 significantly differentially expressed genes in all pairwise comparisons. The overall biological functions of these genes were related to gene ontology terms such as response to toxic substance, leukocyte migration, neutrophil mediated immunity, response to lipopolysaccharide, and response to oxidative stress. At the KEGG pathway level, our results indicated alterations in IL-17, TNF, MAPK and the AGE-RAGE signaling pathways. Conclusion We have shown in previous studies that donor simvastatin treatment induces protective effects against IRI in heart transplant recipients. In this study, we were able to detect significantly differentially expressed genes related to effects of simvastatin treatment. In order to single out genes that show beneficial effects of simvastatin treatment, further analysis will be conducted by exploring gene expression changes in specific biological functional categories, such as interleukin signaling and neutrophil degranulation. The complete analysis will be presented at the ISHLT 2019 congress.Peer reviewe

    A Family of Maximum Margin Criterion for Adaptive Learning

    Full text link
    In recent years, pattern analysis plays an important role in data mining and recognition, and many variants have been proposed to handle complicated scenarios. In the literature, it has been quite familiar with high dimensionality of data samples, but either such characteristics or large data have become usual sense in real-world applications. In this work, an improved maximum margin criterion (MMC) method is introduced firstly. With the new definition of MMC, several variants of MMC, including random MMC, layered MMC, 2D^2 MMC, are designed to make adaptive learning applicable. Particularly, the MMC network is developed to learn deep features of images in light of simple deep networks. Experimental results on a diversity of data sets demonstrate the discriminant ability of proposed MMC methods are compenent to be adopted in complicated application scenarios.Comment: 14 page

    Differences in cardiac geometry in relation to body size among neonates with abnormal prenatal growth and body size at birth

    Get PDF
    Objectives Both excessive and restricted fetal growth are associated with changes in cardiac geometry and function at birth. There are significant issues when indexing cardiac parameters for body size in the neonatal period. The aims of this study were to determine to what extent cardiac geometry is dependent on body size in term and preterm neonates with restricted or excessive fetal growth and how this is affected by adiposity. Methods This was a cross-sectional study of neonates born between 31 and 42 weeks of gestation, divided into three groups: (1) small-for-gestational age (SGA, birth weight > 2 SD below the mean); (2) large-for-gestational age (LGA, birth weight > 2 SD above the mean); and (3) appropriate-for-gestational-age controls (AGA, birth weight Results In total, 174 neonates were included, of which 39 were SGA, 45 were LGA and 90 were AGA. Body size was reflected in cardiac dimensions, with differences in cardiac dimensions disappearing between the SGA and AGA groups when indexed for body surface area (BSA) or thoracic circumference. The same was true for the differences in atrial and ventricular areas between the LGA and AGA groups. However, left ventricular inflow and outflow tract dimensions did not follow this trend as, when indexed for BSA, they were associated negatively with adiposity, resulting in diminished dimensions in LGA compared with AGA and SGA neonates. Adiposity was associated positively with left ventricular mass, right ventricular length and area and right atrial area. The SGA group showed increased right ventricular fractional area change, possibly reflecting differences in the systolic function of the right ventricle. We found evidence of altered diastolic function between the groups, with the mitral valve inflow E-to lateral E'-wave peak velocity ratio being increased in the LGA group and decreased in the SGA group. Conclusions Cardiac geometry is explained by body size in both term and preterm AGA and SGA infants. However, the nature of the relationship between body size and cardiac dimensions may be influenced by adiposity in LGA infants, leading to underestimation of left ventricular inflow and outflow tract dimensions when adjusted for BSA. Adjustments for thoracic circumference provide similar results to those for BSA. Copyright (C) 2020 ISUOG. Published by John Wiley & Sons Ltd.Peer reviewe

    A study of 15N14N isotopic exchange over cobalt molybdenum nitrides

    Get PDF
    The 14N/15N isotopic exchange pathways over Co3Mo3N, a material of interest as an ammonia synthesis catalyst and for the development of nitrogen transfer reactions, have been investigated. Both the homomolecular and heterolytic exchange processes have been studied, and it has been shown that lattice nitrogen species are exchangeable. The exchange behavior was found to be a strong function of pretreatment with ca. 25% of lattice N atoms being exchanged after 40 min at 600 °C after N2 pretreatment at 700 °C compared to only 6% following similar Ar pretreatment. This observation, for which the potential contribution of adsorbed N species can be discounted, is significant in terms of the application of this material. In the case of the Co6Mo6N phase, regeneration to Co3Mo3N under 15N2 at 600 °C occurs concurrently with 14N15N formation. These observations demonstrate the reactivity of nitrogen in the Co–Mo–N system to be a strong function of pretreatment and worthy of further consideration

    Diffraction and Total Cross-Section at the Tevatron and the LHC

    Get PDF
    At the Tevatron, the total p_bar-p cross-section has been measured by CDF at 546 GeV and 1.8 TeV, and by E710/E811 at 1.8 TeV. The two results at 1.8 TeV disagree by 2.6 standard deviations, introducing big uncertainties into extrapolations to higher energies. At the LHC, the TOTEM collaboration is preparing to resolve the ambiguity by measuring the total p-p cross-section with a precision of about 1 %. Like at the Tevatron experiments, the luminosity-independent method based on the Optical Theorem will be used. The Tevatron experiments have also performed a vast range of studies about soft and hard diffractive events, partly with antiproton tagging by Roman Pots, partly with rapidity gap tagging. At the LHC, the combined CMS/TOTEM experiments will carry out their diffractive programme with an unprecedented rapidity coverage and Roman Pot spectrometers on both sides of the interaction point. The physics menu comprises detailed studies of soft diffractive differential cross-sections, diffractive structure functions, rapidity gap survival and exclusive central production by Double Pomeron Exchange.Peer reviewe
    • …
    corecore