541 research outputs found

    New pixelized Micromegas detector for the COMPASS experiment

    Get PDF
    New Micromegas (Micro-mesh gaseous detectors) are being developed in view of the future physics projects planned by the COMPASS collaboration at CERN. Several major upgrades compared to present detectors are being studied: detectors standing five times higher luminosity with hadron beams, detection of beam particles (flux up to a few hundred of kHz/mm^2, 10 times larger than for the present detectors) with pixelized read-out in the central part, light and integrated electronics, and improved robustness. Studies were done with the present detectors moved in the beam, and two first pixelized prototypes are being tested with muon and hadron beams in real conditions at COMPASS. We present here this new project and report on two series of tests, with old detectors moved into the beam and with pixelized prototypes operated in real data taking condition with both muon and hadron beams.Comment: 11 pages, 5 figures, proceedings to the Micro-Pattern Gaseous Detectors conference (MPGD2009), 12-15 June 2009, Kolympari, Crete, Greece Minor details added and language corrections don

    New pixelized Micromegas detector with low discharge rate for the COMPASS experiment

    Full text link
    New Micromegas (Micro-mesh gaseous detectors) are being developed in view of the future physics projects planned by the COMPASS collaboration at CERN. Several major upgrades compared to present detectors are being studied: detectors standing five times higher luminosity with hadron beams, detection of beam particles (flux up to a few hundred of kHz/mm^{2}, 10 times larger than for the present Micromegas detectors) with pixelized read-out in the central part, light and integrated electronics, and improved robustness. Two solutions of reduction of discharge impact have been studied, with Micromegas detectors using resistive layers and using an additional GEM foil. Performance of such detectors has also been measured. A large size prototypes with nominal active area and pixelized read-out has been produced and installed at COMPASS in 2010. In 2011 prototypes featuring an additional GEM foil, as well as an resistive prototype, are installed at COMPASS and preliminary results from those detectors presented very good performance. We present here the project and report on its status, in particular the performance of large size prototypes with an additional GEM foil.Comment: 11 pages, 5 figures, proceedings to the Micro-Pattern Gaseous Detectors conference (MPGD2011), 29-31 August 2011, Kobe, Japa

    Imaging in population science: cardiovascular magnetic resonance in 100,000 participants of UK Biobank - rationale, challenges and approaches

    Get PDF
    PMCID: PMC3668194SEP was directly funded by the National Institute for Health Research Cardiovascular Biomedical Research Unit at Barts. SN acknowledges support from the Oxford NIHR Biomedical Research Centre and from the Oxford British Heart Foundation Centre of Research Excellence. SP and PL are funded by a BHF Senior Clinical Research fellowship. RC is supported by a BHF Research Chair and acknowledges the support of the Oxford BHF Centre for Research Excellence and the MRC and Wellcome Trust. PMM gratefully acknowledges training fellowships supporting his laboratory from the Wellcome Trust, GlaxoSmithKline and the Medical Research Council

    The Spin Structure Function g1pg_1^{\rm p} of the Proton and a Test of the Bjorken Sum Rule

    Get PDF
    New results for the double spin asymmetry A1pA_1^{\rm p} and the proton longitudinal spin structure function g1pg_1^{\rm p} are presented. They were obtained by the COMPASS collaboration using polarised 200 GeV muons scattered off a longitudinally polarised NH3_3 target. The data were collected in 2011 and complement those recorded in 2007 at 160\,GeV, in particular at lower values of xx. They improve the statistical precision of g1p(x)g_1^{\rm p}(x) by about a factor of two in the region x0.02x\lesssim 0.02. A next-to-leading order QCD fit to the g1g_1 world data is performed. It leads to a new determination of the quark spin contribution to the nucleon spin, ΔΣ\Delta \Sigma ranging from 0.26 to 0.36, and to a re-evaluation of the first moment of g1pg_1^{\rm p}. The uncertainty of ΔΣ\Delta \Sigma is mostly due to the large uncertainty in the present determinations of the gluon helicity distribution. A new evaluation of the Bjorken sum rule based on the COMPASS results for the non-singlet structure function g1NS(x,Q2)g_1^{\rm NS}(x,Q^2) yields as ratio of the axial and vector coupling constants gA/gV=1.22±0.05 (stat.)±0.10 (syst.)|g_{\rm A}/g_{\rm V}| = 1.22 \pm 0.05~({\rm stat.}) \pm 0.10~({\rm syst.}), which validates the sum rule to an accuracy of about 9\%.Comment: 19 pages, 8 figures and table

    W(h)ither human cardiac and body magnetic resonance at ultrahigh fields? Technical advances, practical considerations, applications, and clinical opportunities.

    Get PDF
    The objective of this study was to document and review advances and groundbreaking progress in cardiac and body MR at ultrahigh fields (UHF, B0 ≥ 7.0 T) with the goal to attract talent, clinical adopters, collaborations and resources to the biomedical and diagnostic imaging communities. This review surveys traits, advantages and challenges of cardiac and body MR at 7.0 T. The considerations run the gamut from technical advances to clinical opportunities. Key concepts, emerging technologies, practical considerations, frontier applications and future directions of UHF body and cardiac MR are provided. Examples of UHF cardiac and body imaging strategies are demonstrated. Their added value over the kindred counterparts at lower fields is explored along with an outline of research promises. The achievements of cardiac and body UHF-MR are powerful motivators and enablers, since extra speed, signal and imaging capabilities may be invested to overcome the fundamental constraints that continue to hamper traditional cardiac and body MR applications. If practical obstacles, concomitant physics effects and technical impediments can be overcome in equal measure, sophisticated cardiac and body UHF-MR will help to open the door to new MRI and MRS approaches for basic research and clinical science, with the lessons learned at 7.0 T being transferred into broad clinical use including diagnostics and therapy guiding at lower field

    Collins and Sivers asymmetries in muonproduction of pions and kaons off transversely polarised proton

    Get PDF
    Measurements of the Collins and Sivers asymmetries for charged pions and charged and neutral kaons produced in semi-inclusive deep-inelastic scattering of high energy muons off transversely polarised protons are presented. The results were obtained using all the available COMPASS proton data, which were taken in the years 2007 and 2010. The Collins asymmetries exhibit in the valence region a non-zero signal for pions and there are hints of non-zero signal also for kaons. The Sivers asymmetries are found to be positive for positive pions and kaons and compatible with zero otherwise.Comment: 15 pages, 13 figures and 1 tabl

    Measurement of the charged-pion polarisability

    Get PDF
    The COMPASS collaboration at CERN has investigated pion Compton scattering, πγπγ\pi^-\gamma\rightarrow \pi^-\gamma, at centre-of-mass energy below 3.5 pion masses. The process is embedded in the reaction πNiπγ  Ni\pi^-\mathrm{Ni}\rightarrow\pi^-\gamma\;\mathrm{Ni}, which is initiated by 190\,GeV pions impinging on a nickel target. The exchange of quasi-real photons is selected by isolating the sharp Coulomb peak observed at smallest momentum transfers, Q2<0.0015Q^2<0.0015\,(GeV/cc)2^2. From a sample of 63\,000 events the pion electric polarisability is determined to be $\alpha_\pi\ =\ (\,2.0\ \pm\ 0.6_{\mbox{\scriptsize stat}}\ \pm\ 0.7_{\mbox{\scriptsize syst}}\,) \times 10^{-4}\,\mbox{fm}^3undertheassumption under the assumption \alpha_\pi=-\beta_\pi$, which relates the electric and magnetic dipole polarisabilities. It is the most precise measurement of this fundamental low-energy parameter of strong interaction, that has been addressed since long by various methods with conflicting outcomes. While this result is in tension with previous dedicated measurements, it is found in agreement with the expectation from chiral perturbation theory. An additional measurement replacing pions by muons, for which the cross-section behavior is unambigiously known, was performed for an independent estimate of the systematic uncertainty.Comment: Published version: 9 pages, 3 figures, 1 tabl

    Spin alignment and violation of the OZI rule in exclusive ω\omega and ϕ\phi production in pp collisions

    Get PDF
    Exclusive production of the isoscalar vector mesons ω\omega and ϕ\phi is measured with a 190 GeV/c/c proton beam impinging on a liquid hydrogen target. Cross section ratios are determined in three intervals of the Feynman variable xFx_{F} of the fast proton. A significant violation of the OZI rule is found, confirming earlier findings. Its kinematic dependence on xFx_{F} and on the invariant mass MpVM_{p\mathrm{V}} of the system formed by fast proton pfastp_\mathrm{fast} and vector meson VV is discussed in terms of diffractive production of pfastVp_\mathrm{fast}V resonances in competition with central production. The measurement of the spin density matrix element ρ00\rho_{00} of the vector mesons in different selected reference frames provides another handle to distinguish the contributions of these two major reaction types. Again, dependences of the alignment on xFx_{F} and on MpVM_{p\mathrm{V}} are found. Most of the observations can be traced back to the existence of several excited baryon states contributing to ω\omega production which are absent in the case of the ϕ\phi meson. Removing the low-mass MpVM_{p\mathrm{V}} resonant region, the OZI rule is found to be violated by a factor of eight, independently of xFx_\mathrm{F}.Comment: 23 pages, 13 figures and 5 table

    Search for exclusive photoproduction of Zc±_c^{\pm}(3900) at COMPASS

    Get PDF
    A search for the exclusive production of the Zc±(3900)Z_c^{\pm}(3900) hadron by virtual photons has been performed in the channel Zc±(3900)J/ψπ±Z_c^{\pm}(3900)\rightarrow J/\psi \pi^{\pm}. The data cover the range from 7 GeV to 19 GeV in the centre-of-mass energy of the photon-nucleon system. The full set of the COMPASS data set collected with a muon beam between 2002 and 2011 has been used. An upper limit for the ratio BR(Zc±(3900)J/ψπ±)×σγ NZc±(3900) N/σγ NJ/ψ NBR(Z_c^{\pm}(3900)\rightarrow J/\psi \pi^{\pm} )\times \sigma_{ \gamma~N \rightarrow Z_c^{\pm}(3900)~ N} /\sigma_{\gamma~N \rightarrow J/\psi~ N} of 3.7×1033.7\times10^{-3} has been established at the confidence level of 90%.Comment: 8 pages, 3 figures, 1 tabl