541 research outputs found
New pixelized Micromegas detector for the COMPASS experiment
New Micromegas (Micro-mesh gaseous detectors) are being developed in view of
the future physics projects planned by the COMPASS collaboration at CERN.
Several major upgrades compared to present detectors are being studied:
detectors standing five times higher luminosity with hadron beams, detection of
beam particles (flux up to a few hundred of kHz/mm^2, 10 times larger than for
the present detectors) with pixelized read-out in the central part, light and
integrated electronics, and improved robustness. Studies were done with the
present detectors moved in the beam, and two first pixelized prototypes are
being tested with muon and hadron beams in real conditions at COMPASS. We
present here this new project and report on two series of tests, with old
detectors moved into the beam and with pixelized prototypes operated in real
data taking condition with both muon and hadron beams.Comment: 11 pages, 5 figures, proceedings to the Micro-Pattern Gaseous
Detectors conference (MPGD2009), 12-15 June 2009, Kolympari, Crete, Greece
Minor details added and language corrections don
EFFECTS OF K201 ON REPOLARIZATION AND ARRHYTHMOGENESIS IN DOGS WITH CHRONIC COMPLETE ATRIOVENTRICULAR BLOCK
New pixelized Micromegas detector with low discharge rate for the COMPASS experiment
New Micromegas (Micro-mesh gaseous detectors) are being developed in view of
the future physics projects planned by the COMPASS collaboration at CERN.
Several major upgrades compared to present detectors are being studied:
detectors standing five times higher luminosity with hadron beams, detection of
beam particles (flux up to a few hundred of kHz/mm^{2}, 10 times larger than
for the present Micromegas detectors) with pixelized read-out in the central
part, light and integrated electronics, and improved robustness. Two solutions
of reduction of discharge impact have been studied, with Micromegas detectors
using resistive layers and using an additional GEM foil. Performance of such
detectors has also been measured. A large size prototypes with nominal active
area and pixelized read-out has been produced and installed at COMPASS in 2010.
In 2011 prototypes featuring an additional GEM foil, as well as an resistive
prototype, are installed at COMPASS and preliminary results from those
detectors presented very good performance. We present here the project and
report on its status, in particular the performance of large size prototypes
with an additional GEM foil.Comment: 11 pages, 5 figures, proceedings to the Micro-Pattern Gaseous
Detectors conference (MPGD2011), 29-31 August 2011, Kobe, Japa
Imaging in population science: cardiovascular magnetic resonance in 100,000 participants of UK Biobank - rationale, challenges and approaches
PMCID: PMC3668194SEP was directly funded by the National Institute for Health Research
Cardiovascular Biomedical Research Unit at Barts. SN acknowledges support
from the Oxford NIHR Biomedical Research Centre and from the Oxford
British Heart Foundation Centre of Research Excellence. SP and PL are
funded by a BHF Senior Clinical Research fellowship. RC is supported by a
BHF Research Chair and acknowledges the support of the Oxford BHF Centre
for Research Excellence and the MRC and Wellcome Trust. PMM gratefully
acknowledges training fellowships supporting his laboratory from the
Wellcome Trust, GlaxoSmithKline and the Medical Research Council
The Spin Structure Function of the Proton and a Test of the Bjorken Sum Rule
New results for the double spin asymmetry and the proton
longitudinal spin structure function are presented. They were
obtained by the COMPASS collaboration using polarised 200 GeV muons scattered
off a longitudinally polarised NH target. The data were collected in 2011
and complement those recorded in 2007 at 160\,GeV, in particular at lower
values of . They improve the statistical precision of by
about a factor of two in the region . A next-to-leading order
QCD fit to the world data is performed. It leads to a new determination
of the quark spin contribution to the nucleon spin, ranging
from 0.26 to 0.36, and to a re-evaluation of the first moment of .
The uncertainty of is mostly due to the large uncertainty in
the present determinations of the gluon helicity distribution. A new evaluation
of the Bjorken sum rule based on the COMPASS results for the non-singlet
structure function yields as ratio of the axial and
vector coupling constants , which validates the sum rule to an accuracy of about
9\%.Comment: 19 pages, 8 figures and table
W(h)ither human cardiac and body magnetic resonance at ultrahigh fields? Technical advances, practical considerations, applications, and clinical opportunities.
The objective of this study was to document and review advances and groundbreaking progress in cardiac and body MR at ultrahigh fields (UHF, B0 ≥ 7.0 T) with the goal to attract talent, clinical adopters, collaborations and resources to the biomedical and diagnostic imaging communities. This review surveys traits, advantages and challenges of cardiac and body MR at 7.0 T. The considerations run the gamut from technical advances to clinical opportunities. Key concepts, emerging technologies, practical considerations, frontier applications and future directions of UHF body and cardiac MR are provided. Examples of UHF cardiac and body imaging strategies are demonstrated. Their added value over the kindred counterparts at lower fields is explored along with an outline of research promises. The achievements of cardiac and body UHF-MR are powerful motivators and enablers, since extra speed, signal and imaging capabilities may be invested to overcome the fundamental constraints that continue to hamper traditional cardiac and body MR applications. If practical obstacles, concomitant physics effects and technical impediments can be overcome in equal measure, sophisticated cardiac and body UHF-MR will help to open the door to new MRI and MRS approaches for basic research and clinical science, with the lessons learned at 7.0 T being transferred into broad clinical use including diagnostics and therapy guiding at lower field
Collins and Sivers asymmetries in muonproduction of pions and kaons off transversely polarised proton
Measurements of the Collins and Sivers asymmetries for charged pions and
charged and neutral kaons produced in semi-inclusive deep-inelastic scattering
of high energy muons off transversely polarised protons are presented. The
results were obtained using all the available COMPASS proton data, which were
taken in the years 2007 and 2010. The Collins asymmetries exhibit in the
valence region a non-zero signal for pions and there are hints of non-zero
signal also for kaons. The Sivers asymmetries are found to be positive for
positive pions and kaons and compatible with zero otherwise.Comment: 15 pages, 13 figures and 1 tabl
Measurement of the charged-pion polarisability
The COMPASS collaboration at CERN has investigated pion Compton scattering,
, at centre-of-mass energy below 3.5 pion
masses. The process is embedded in the reaction
, which is initiated by
190\,GeV pions impinging on a nickel target. The exchange of quasi-real photons
is selected by isolating the sharp Coulomb peak observed at smallest momentum
transfers, \,(GeV/). From a sample of 63\,000 events the
pion electric polarisability is determined to be $\alpha_\pi\ =\ (\,2.0\ \pm\
0.6_{\mbox{\scriptsize stat}}\ \pm\ 0.7_{\mbox{\scriptsize syst}}\,) \times
10^{-4}\,\mbox{fm}^3\alpha_\pi=-\beta_\pi$, which
relates the electric and magnetic dipole polarisabilities. It is the most
precise measurement of this fundamental low-energy parameter of strong
interaction, that has been addressed since long by various methods with
conflicting outcomes. While this result is in tension with previous dedicated
measurements, it is found in agreement with the expectation from chiral
perturbation theory. An additional measurement replacing pions by muons, for
which the cross-section behavior is unambigiously known, was performed for an
independent estimate of the systematic uncertainty.Comment: Published version: 9 pages, 3 figures, 1 tabl
Spin alignment and violation of the OZI rule in exclusive and production in pp collisions
Exclusive production of the isoscalar vector mesons and is
measured with a 190 GeV proton beam impinging on a liquid hydrogen target.
Cross section ratios are determined in three intervals of the Feynman variable
of the fast proton. A significant violation of the OZI rule is found,
confirming earlier findings. Its kinematic dependence on and on the
invariant mass of the system formed by fast proton
and vector meson is discussed in terms of diffractive
production of resonances in competition with central
production. The measurement of the spin density matrix element of
the vector mesons in different selected reference frames provides another
handle to distinguish the contributions of these two major reaction types.
Again, dependences of the alignment on and on are
found. Most of the observations can be traced back to the existence of several
excited baryon states contributing to production which are absent in
the case of the meson. Removing the low-mass resonant
region, the OZI rule is found to be violated by a factor of eight,
independently of .Comment: 23 pages, 13 figures and 5 table
Search for exclusive photoproduction of Z(3900) at COMPASS
A search for the exclusive production of the hadron by
virtual photons has been performed in the channel . The data cover the range from 7 GeV to 19 GeV in the
centre-of-mass energy of the photon-nucleon system. The full set of the COMPASS
data set collected with a muon beam between 2002 and 2011 has been used. An
upper limit for the ratio of has been established at the confidence
level of 90%.Comment: 8 pages, 3 figures, 1 tabl
- …