1,457 research outputs found

    Quantum-enhanced measurements without entanglement

    Get PDF
    Quantum-enhanced measurements exploit quantum mechanical effects for increasing the sensitivity of measurements of certain physical parameters and have great potential for both fundamental science and concrete applications. Most of the research has so far focused on using highly entangled states, which are, however, difficult to produce and to stabilize for a large number of constituents. In the following we review alternative mechanisms, notably the use of more general quantum correlations such as quantum discord, identical particles, or non-trivial Hamiltonians; the estimation of thermodynamical parameters or parameters characterizing non-equilibrium states; and the use of quantum phase transitions. We describe both theoretically achievable enhancements and enhanced sensitivities, not primarily based on entanglement, that have already been demonstrated experimentally, and indicate some possible future research directions

    Are we close to the QGP? - Hadrochemical vs. microscopic analysis of particle production in ultrarelativistic heavy ion collisions

    Get PDF
    Ratios of hadronic abundances are analyzed for pp and nucleus-nucleus collisions at sqrt(s)=20 GeV using the microscopic transport model UrQMD. Secondary interactions significantly change the primordial hadronic cocktail of the system. A comparison to data shows a strong dependence on rapidity. Without assuming thermal and chemical equilibrium, predicted hadron yields and ratios agree with many of the data, the few observed discrepancies are discussed.Comment: 12 pages, 4 figure

    The catalytic subunit of the system L1 amino acid transporter (S<i>lc7a5</i>) facilitates nutrient signalling in mouse skeletal muscle

    Get PDF
    The System L1-type amino acid transporter mediates transport of large neutral amino acids (LNAA) in many mammalian cell-types. LNAA such as leucine are required for full activation of the mTOR-S6K signalling pathway promoting protein synthesis and cell growth. The SLC7A5 (LAT1) catalytic subunit of high-affinity System L1 functions as a glycoprotein-associated heterodimer with the multifunctional protein SLC3A2 (CD98). We generated a floxed Slc7a5 mouse strain which, when crossed with mice expressing Cre driven by a global promoter, produced Slc7a5 heterozygous knockout (Slc7a5+/-) animals with no overt phenotype, although homozygous global knockout of Slc7a5 was embryonically lethal. Muscle-specific (MCK Cre-mediated) Slc7a5 knockout (MS-Slc7a5-KO) mice were used to study the role of intracellular LNAA delivery by the SLC7A5 transporter for mTOR-S6K pathway activation in skeletal muscle. Activation of muscle mTOR-S6K (Thr389 phosphorylation) in vivo by intraperitoneal leucine injection was blunted in homozygous MS-Slc7a5-KO mice relative to wild-type animals. Dietary intake and growth rate were similar for MS-Slc7a5-KO mice and wild-type littermates fed for 10 weeks (to age 120 days) with diets containing 10%, 20% or 30% of protein. In MS-Slc7a5-KO mice, Leu and Ile concentrations in gastrocnemius muscle were reduced by ∼40% as dietary protein content was reduced from 30 to 10%. These changes were associated with >50% decrease in S6K Thr389 phosphorylation in muscles from MS-Slc7a5-KO mice, indicating reduced mTOR-S6K pathway activation, despite no significant differences in lean tissue mass between groups on the same diet. MS-Slc7a5-KO mice on 30% protein diet exhibited mild insulin resistance (e.g. reduced glucose clearance, larger gonadal adipose depots) relative to control animals. Thus, SLC7A5 modulates LNAA-dependent muscle mTOR-S6K signalling in mice, although it appears non-essential (or is sufficiently compensated by e.g. SLC7A8 (LAT2)) for maintenance of normal muscle mass

    Measurement of the Charged Pion Electromagnetic Form Factor

    Get PDF
    Separated longitudinal and transverse structure functions for the reaction 1H(e,eprime pi+)n were measured in the momentum transfer region Q2=0.6-1.6 (GeV/c)**2 at a value of the invariant mass W=1.95 GeV. New values for the pion charge form factor were extracted from the longitudinal cross section by using a recently developed Regge model. The results indicate that the pion form factor in this region is larger than previously assumed and is consistent with a monopole parameterization fitted to very low Q2 elastic data.Comment: 5 pages, 3 figure

    The Super-TIGER Instrument to Probe Galactic Cosmic Ray Origins

    Get PDF
    Super-TIGER (Super Trans-Iron Galactic Element Recorder) is under construction for the first of two planned Antarctic long-duration balloon flights in December 2012. This new instrument will measure the abundances of ultra-heavy elements (30Zn and heavier), with individual element resolution, to provide sensitive tests of the emerging model of cosmic-ray origins in OB associations and models of the mechanism for selection of nuclei for acceleration. Super-TIGER builds on the techniques of TIGER, which produced the first well-resolved measurements of elemental abundances of the elements 31Ga, 32Ge, and 34Se. Plastic scintillators together with acrylic and silica-aerogel Cherenkov detectors measure particle charge. Scintillating-fiber hodoscopes track particle trajectories. Super-TIGER has an active area of 5.4 sq m, divided into two independent modules. With reduced material thickness to decrease interactions, its effective geometry factor is approx.6.4 times larger than TIGER, allowing it to measure elements up to 42Mo with high statistical precision, and make exploratory measurements up to 56Ba. Super-TIGER will also accurately determine the energy spectra of the more abundant elements from l0Ne to 28Ni between 0.8 and 10 GeV/nucleon to test the hypothesis that microquasars or other sources could superpose spectral features. We will discuss the implications of Super-TIGER measurements for the study of cosmic-ray origins and will present the measurement technique, design, status, and expected performance, including numbers of events and resolution. Details of the hodoscopes, scintillators, and Cherenkov detectors will be given in other presentations at this conference

    Moxibustion for cephalic version: a feasibility randomised controlled trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Moxibustion (a type of Chinese medicine which involves burning a herb close to the skin) has been used to correct a breech presentation. Evidence of effectiveness and safety from systematic reviews is encouraging although significant heterogeneity has been found among trials. We assessed the feasibility of conducting a randomised controlled trial of moxibustion plus usual care compared with usual care to promote cephalic version in women with a breech presentation, and examined the views of women and health care providers towards implementing a trial within an Australian context.</p> <p>Methods</p> <p>The study was undertaken at a public hospital in Newcastle, New South Wales, Australia. Women at 34-36.5 weeks of gestation with a singleton breech presentation (confirmed by ultrasound), were randomised to moxibustion plus usual care or usual care alone. The intervention was administered over 10 days. Clinical outcomes included cephalic presentation at birth, the need for ECV, mode of birth; perinatal morbidity and mortality, and maternal complications. Feasibility outcomes included: recruitment rate, acceptability, compliance and a sample size for a future study. Interviews were conducted with 19 midwives and obstetricians to examine the acceptability of moxibustion, and views on the trial.</p> <p>Results</p> <p>Twenty women were randomised to the trial. Fifty one percent of women approached accepted randomisation to the trial. A trend towards an increase in cephalic version at delivery (RR 5.0; 95% CI 0.7-35.5) was found for women receiving moxibustion compared with usual care. There was also a trend towards greater success with version following ECV. Two babies were admitted to the neonatal unit from the moxibustion group. Compliance with the moxibustion protocol was acceptable with no reported side effects. Clinicians expressed the need for research to establish the safety and efficacy of moxibustion, and support for the intervention was given to increase women's choices, and explore opportunities to normalise birth. The sample size for a future trial is estimated to be 381 women.</p> <p>Conclusion</p> <p>Our findings should be interpreted with caution as the study was underpowered to detect statistical differences between groups. Acceptance by women and health professionals towards moxibustion suggest further research is warranted.</p> <p>Trial Registration</p> <p>Australia and New Zealand Clinical Trials Register (ANZCTR): <a href="http://www.anzctr.org.au/ACTRN12609000985280.aspx">ACTRN12609000985280</a></p

    Development of a multiplexed bead-based immunoassay for the simultaneous detection of antibodies to 17 pneumococcal proteins

    Get PDF
    Presently, several pneumococcal proteins are being evaluated as potential vaccine candidates. Here, we gather novel insights in the immunogenicity of PLY, PsaA, PspA, PspC, NanA, Hyl, PpmA, SlrA, Eno, IgA1-protease, PdBD, BVH-3, SP1003, SP1633, SP1651, SP0189 and SP0376. We developed a multiplex bead-based immunoassay (xMAP® Technology, Luminex Corporation) to simultaneously quantify antibodies against these 17 pneumococcal proteins in serum. The median fluorescence intensity (MFI) values obtained for human pooled serum with the multiplex assay were between 82% and 111% (median 94%) of those obtained with the singleplex assays. For IgG, the coefficient of variation (CV) in serum ranged from 2% to 9%, for IgA, the CV ranged from 3% to 14% and for IgM, the CV ranged from 11% to 15%. Using this immunoassay, we showed that anti-pneumococcal antibody levels exhibited extensive inter-individual variability in young children suffering from invasive pneumococcal disease. All proteins, including the proteins with, as yet, unknown function, were immunogenic. In conclusion, the multiplex Streptococcus pneumoniae immunoassay based on proteins is reproducible. This assay can be used to monitor anti-S. pneumoniae antibody responses in a material- and time-saving manner

    THE SuperTIGER Instrument: Measurement of Elemental Abundances of Ultra-Heavy Galactic Cosmic Rays

    Get PDF
    The SuperTIGER (Super Trans-Iron Galactic Element Recorder) instrument was developed to measure the abundances of galactic cosmic-ray elements from Ne-10 to Zr-40 with individual element resolution and the high statistics needed to test models of cosmic-ray origins. SuperTIGER also makes exploratory measurements of the abundances of elements with 40 or = 10, including approx.1300 with Z > 29 and approx.60 with Z > 49. Here, we describe the instrument, the methods of charge identification employed, the SuperTIGER balloon flight, and the instrument performance

    ARPES: A probe of electronic correlations

    Full text link
    Angle-resolved photoemission spectroscopy (ARPES) is one of the most direct methods of studying the electronic structure of solids. By measuring the kinetic energy and angular distribution of the electrons photoemitted from a sample illuminated with sufficiently high-energy radiation, one can gain information on both the energy and momentum of the electrons propagating inside a material. This is of vital importance in elucidating the connection between electronic, magnetic, and chemical structure of solids, in particular for those complex systems which cannot be appropriately described within the independent-particle picture. Among the various classes of complex systems, of great interest are the transition metal oxides, which have been at the center stage in condensed matter physics for the last four decades. Following a general introduction to the topic, we will lay the theoretical basis needed to understand the pivotal role of ARPES in the study of such systems. After a brief overview on the state-of-the-art capabilities of the technique, we will review some of the most interesting and relevant case studies of the novel physics revealed by ARPES in 3d-, 4d- and 5d-based oxides.Comment: Chapter to appear in "Strongly Correlated Systems: Experimental Techniques", edited by A. Avella and F. Mancini, Springer Series in Solid-State Sciences (2013). A high-resolution version can be found at: http://www.phas.ubc.ca/~quantmat/ARPES/PUBLICATIONS/Reviews/ARPES_Springer.pdf. arXiv admin note: text overlap with arXiv:cond-mat/0307085, arXiv:cond-mat/020850
    corecore