505 research outputs found

    CP violation and mass hierarchy at medium baselines in the large theta(13) era

    Full text link
    The large value of theta(13) recently measured by rector and accelerator experiments opens unprecedented opportunities for precision oscillation physics. In this paper, we reconsider the physics reach of medium baseline superbeams. For theta(13) ~ 9 degree we show that facilities at medium baselines -- i.e. L ~ O(1000 km) -- remain optimal for the study of CP violation in the leptonic sector, although their ultimate precision strongly depends on experimental systematics. This is demonstrated in particular for facilities of practical interest in Europe: a CERN to Gran Sasso and CERN to Phyasalmi nu_mu beam based on the present SPS and on new high power 50 GeV proton driver. Due to the large value of theta(13), spectral information can be employed at medium baselines to resolve the sign ambiguity and determine the neutrino mass hierarchy. However, longer baselines, where matter effects dominate the nu_mu->nu_e transition, can achieve much stronger sensitivity to sign(Delta m^2) even at moderate exposures.Comment: 14 pages, 14 figures, version to appear in EPJ

    Study of the performance of a large scale water-Cherenkov detector (MEMPHYS)

    Full text link
    MEMPHYS (MEgaton Mass PHYSics) is a proposed large-scale water Cherenkov experiment to be performed deep underground. It is dedicated to nucleon decay searches, neutrinos from supernovae, solar and atmospheric neutrinos, as well as neutrinos from a future Super-Beam or Beta-Beam to measure the CP violating phase in the leptonic sector and the mass hierarchy. A full simulation of the detector has been performed to evaluate its performance for beam physics. The results are given in terms of "Migration Matrices" of reconstructed versus true neutrino energy, taking into account all the experimental effects.Comment: Updated after JCAP's referee's comment

    Future large-scale water-Cherenkov detector

    Full text link
    MEMPHYS (MEgaton Mass PHYSics) is a proposed large-scale water-Cherenkov experiment to be performed deep underground. It is dedicated to nucleon decay searches and the detection of neutrinos from supernovae, solar, and atmospheric neutrinos, as well as neutrinos from a future beam to measure the CP violating phase in the leptonic sector and the mass hierarchy. This paper provides an overview of the latest studies on the expected performance of MEMPHYS in view of detailed estimates of its physics reach, mainly concerning neutrino beams

    Hybrid rescue technique after failure of a standard multibranched stent graft

    Get PDF
    A 78-year-old woman presented with type IIIC and IIID endoleaks after endovascular treatment for a thoracoabdominal aortic aneurysm. Mating between the ruptured segments of superior mesenteric artery stent graft was performed. After failed attempts at relining the right renal artery stent graft, a hybrid approach was used to connect the side branch to the target vessel: a stent graft was deployed into the side branch of the main graft and it was temporarily occluded with a balloon. After opening the sac, a stent graft was deployed into the right renal artery and the two stent grafts were connected with a running suture. Follow-up examination performed 1 month postoperatively by computed tomography imaging confirmed the effectiveness of this treatment

    Where we are on θ13\theta_{13}: addendum to "Global neutrino data and recent reactor fluxes: status of three-flavour oscillation parameters"

    Get PDF
    In this addendum to arXiv:1103.0734 we consider the recent results from long-baseline νμνe\nu_\mu\to\nu_e searches at the T2K and MINOS experiments and investigate their implications for the mixing angle θ13\theta_{13} and the leptonic Dirac CP phase δ\delta. By combining the 2.5σ2.5\sigma indication for a non-zero value of θ13\theta_{13} coming from T2K data with global neutrino oscillation data we obtain a significance for θ13>0\theta_{13} > 0 of about 3σ3\sigma with best fit points sin2θ13=0.013(0.016)\sin^2\theta_{13} = 0.013(0.016) for normal (inverted) neutrino mass ordering. These results depend somewhat on assumptions concerning the analysis of reactor neutrino data.Comment: 5 pages, 2 figures and 1 tabl

    MEMPHYS:A large scale water Cerenkov detector at Fr\'ejus

    Full text link
    A water \v{C}erenkov detector project, of megaton scale, to be installed in the Fr\'ejus underground site and dedicated to nucleon decay, neutrinos from supernovae, solar and atmospheric neutrinos, as well as neutrinos from a super-beam and/or a beta-beam coming from CERN, is presented and compared with competitor projects in Japan and in the USA. The performances of the European project are discussed, including the possibility to measure the mixing angle θ13\theta_{13} and the CP-violating phase δ\delta.Comment: 1+33 pages, 14 figures, Expression of Interest of MEMPHYS projec

    A minimal Beta Beam with high-Q ions to address CP violation in the leptonic sector

    Get PDF
    In this paper we consider a Beta Beam setup that tries to leverage at most existing European facilities: i.e. a setup that takes advantage of facilities at CERN to boost high-Q ions (8Li and 8B) aiming at a far detector located at L = 732 Km in the Gran Sasso Underground Laboratory. The average neutrino energy for 8Li and 8B ions boosted at \gamma ~ 100 is in the range E_\nu = [1,2] GeV, high enough to use a large iron detector of the MINOS type at the far site. We perform, then, a study of the neutrino and antineutrino fluxes needed to measure a CP-violating phase delta in a significant part of the parameter space. In particular, for theta_13 > 3 deg, if an antineutrino flux of 3 10^19 useful 8Li decays per year is achievable, we find that delta can be measured in 60% of the parameter space with 6 10^18 useful 8B decays per year.Comment: 19 pages, 10 figures, added references and corrected typo

    A Beta Beam complex based on the machine upgrades for the LHC

    Get PDF
    The Beta Beam CERN design is based on the present LHC injection complex and its physics reach is mainly limited by the maximum rigidity of the SPS. In fact, some of the scenarios for the machine upgrades of the LHC, particularly the construction of a fast cycling 1 TeV injector (``Super-SPS''), are very synergic with the construction of a higher γ\gamma Beta Beam. At the energies that can be reached by this machine, we demonstrate that dense calorimeters can already be used for the detection of ν\nu at the far location. Even at moderate masses (40 kton) as the ones imposed by the use of existing underground halls at Gran Sasso, the CP reach is very large for any value of θ13\theta_{13} that would provide evidence of νe\nu_e appearance at T2K or NOν\nuA (θ133\theta_{13}\geq 3^\circ). Exploitation of matter effects at the CERN to Gran Sasso distance provides sensitivity to the neutrino mass hierarchy in significant areas of the θ13δ\theta_{13}-\delta plane

    Kidney transplantation from living donor with monolateral renal artery fibromuscular dysplasia using a cryopreserved iliac graft for arterial reconstruction: a case report and review of the literature

    Get PDF
    Background Aging and mortality of patients on waiting lists for kidney transplantation have increased, as a result of the shortage of organs available all over the world. Living donor grafts represent a significant source to maintain the donor pool, and resorting successfully to allografts with arterial disease has become a necessity. The incidence of renal artery fibromuscular dysplasia (FMD) in potential living renal donors is reported to be 2-6%, and up to 4% of them present concurrent extra-renal involvement. Case presentation We present a case of renal transplantation using a kidney from a living donor with monolateral FMD. Resection of the affected arterial segment and its subsequent replacement with a cryopreserved iliac artery graft from a deceased donor were performed. No intraoperative nor post-operative complications were reported. The allograft function promptly resumed, with satisfying creatinine clearance, and adequate patency of the vascular anastomoses was detected by Doppler ultrasounds. Conclusion Literature lacks clear guidelines on the eligibility of potential living renal donors with asymptomatic FMD. Preliminary assessment of the FMD living donor should always rule out any extra-renal involvement. Whenever possible, resection and reconstruction of the affected arterial segment should be taken into consideration as this condition may progress after implantation

    Neutrino physics at accelerators

    Get PDF
    Present and future neutrino experiments at accelerators are mainly concerned with understanding the neutrino oscillation phenomenon and its implications. Here a brief account of neutrino oscillations is given together with a description of the supporting data. Some current and planned accelerator neutrino experiments are also explained.Comment: 23 pages, 24 figures. Talk given at the Corfu Summer Institute on Elementary Particle Physics 200
    corecore