970 research outputs found
Foot and ankle injuries during the Athens 2004 Olympic Games
<p>Abstract</p> <p>Background</p> <p>Major, rare and complex incidents can occur at any mass-gathering sporting event and team medical staff should be appropriately prepared for these. One such event, the Athens Olympic Games in 2004, presented a significant sporting and medical challenge. This study concerns an epidemiological analysis of foot and ankle injuries during the Games.</p> <p>Methods</p> <p>An observational, epidemiological survey was used to analyse injuries in all sport tournaments (men's and women's) over the period of the Games.</p> <p>Results</p> <p>A total of 624 injuries (525 soft tissue injuries and 99 bony injuries) were reported. The most frequent diagnoses were contusions, sprains, fractures, dislocations and lacerations. Significantly more injuries in male (58%) versus female athletes (42%) were recorded. The incidence, diagnosis and cause of injuries differed substantially between the team sports.</p> <p>Conclusion</p> <p>Our experience from the Athens Olympic Games will inform the development of public health surveillance systems for future Olympic Games, as well as other similar mass events.</p
Measurement of Lifetime and Decay-Width Difference in B0s -> J/psi phi Decays
We measure the mean lifetime, tau=2/(Gamma_L+Gamma_H), and the width
difference, DeltaGamma=Gamma_L-Gamma_H, of the light and heavy mass eigenstates
of the B0s meson, B0sL and B0sH, in B0s -> J/psi phi decays using 1.7 fb^-1 of
data collected with the CDF II detector at the Fermilab Tevatron ppbar
collider. Assuming CP conservation, a good approximation for the B0s system in
the Standard Model, we obtain DeltaGamma = 0.076^+0.059_-0.063 (stat.) +- 0.006
(syst.) ps^-1 and tau = 1.52 +- 0.04 (stat.) +- 0.02 (syst.) ps, the most
precise measurements to date. Our constraints on the weak phase and DeltaGamma
are consistent with CP conservation.
Dedicated to the memory of our dear friend and colleague, Michael P. Schmid
Search for Pair Production of Scalar Top Quarks Decaying to a tau Lepton and a b Quark in ppbar Collisions at sqrt{s}=1.96 TeV
We search for pair production of supersymmetric top quarks (~t_1), followed
by R-parity violating decay ~t_1 -> tau b with a branching ratio beta, using
322 pb^-1 of ppbar collisions at sqrt{s}=1.96 TeV collected by the CDF II
detector at Fermilab. Two candidate events pass our final selection criteria,
consistent with the standard model expectation. We set upper limits on the
cross section sigma(~t_1 ~tbar_1)*beta^2 as a function of the stop mass
m(~t_1). Assuming beta=1, we set a 95% confidence level limit m(~t_1)>153
GeV/c^2. The limits are also applicable to the case of a third generation
scalar leptoquark (LQ_3) decaying LQ_3 -> tau b.Comment: 7 pages, 2 eps figure
Search for New Physics in Lepton + Photon + X Events with L=305 pb-1 of ppbar Collisions at roots=1.96 TeV
We present results of a search for anomalous production of events containing
a charged lepton (either electron or muon) and a photon, both with high
transverse momentum, accompanied by additional signatures, X, including missing
transverse energy (MET) and additional leptons and photons. We use the same
kinematic selection criteria as in a previous CDF search, but with a
substantially larger data set, 305 pb-1, a ppbar collision energy of 1.96 TeV,
and the upgraded CDF II detector. We find 42 Lepton+Photon+MET events versus a
standard model expectation of 37.3 +- 5.4 events. The level of excess observed
in Run I, 16 events with an expectation of 7.6 +- 0.7 events (corresponding to
a 2.7 sigma effect), is not supported by the new data. In the signature of
Multi-Lepton+Photon+X we observe 31 events versus an expectation of 23.0 +- 2.7
events. In this sample we find no events with an extra photon or MET and so
find no events like the one ee+gg+MET event observed in Run I.Comment: 7 pages, 3 figures, 1 table. Accepted to PR
Top Quark Mass Measurement from Dilepton Events at CDF II with the Matrix-Element Method
We describe a measurement of the top quark mass using events with two charged
leptons collected by the CDF II detector from collisions with TeV at the Fermilab Tevatron. The likelihood in top mass is
calculated for each event by convoluting the leading order matrix element
describing
with detector resolution functions. The presence of background events in the
data sample is modeled using similar calculations involving the matrix elements
for major background processes. In a data sample with integrated luminosity of
340 pb, we observe 33 candidate events and measure This
measurement represents the first application of this method to events with two
charged leptons and is the most precise single measurement of the top quark
mass in this channel.Comment: 21 pages, 14 figure
Measurement of B(t->Wb)/B(t->Wq) at the Collider Detector at Fermilab
We present a measurement of the ratio of top-quark branching fractions R= B(t
-> Wb)/B(t -> Wq), where q can be a b, s or a d quark, using lepton-plus-jets
and dilepton data sets with integrated luminosity of ~162 pb^{-1} collected
with the Collider Detector at Fermilab during Run II of the Tevatron. The
measurement is derived from the relative numbers of t-tbar events with
different multiplicity of identified secondary vertices. We set a lower limit
of R > 0.61 at 95% confidence level.Comment: 7 pages, 2 figures, published in Physical Review Letters; changes
made to be consistent with published versio
Measurement of the Top-Quark Mass in All-Hadronic Decays in p pbar Collisions at CDF II
We present a measurement of the top-quark mass, , in the
all-hadronic decay channel . The analysis is performed using 310 pb of
=1.96 TeV collisions collected with the CDF II detector
using a multi-jet trigger. The mass measurement is based on an event-by-event
likelihood which depends on both the sample purity and the value of the
top-quark mass, using 90 possible jet-to-parton assignments in the six-jet
final state. The joint likelihood of 290 selected events yields a value of
=177.1 4.9 (stat.) 4.7 (syst.) GeV/.Comment: 7 pages, 2 figures and 1 table, Submitted to Phys. Rev. Let
Limits on Anomalous Triple Gauge Couplings in ppbar Collisions at sqrt{s}=1.96 TeV
We present a search for anomalous triple gauge couplings (ATGC) in WW and WZ
boson production. The boson pairs are produced in ppbar collisions at
sqrt{s}=1.96 TeV, and the data sample corresponds to 350 pb-1 of integrated
luminosity collected with the CDF II detector at the Fermilab Tevatron. In this
search one W decays to leptons, and the other boson (W or Z) decays
hadronically. Combining with a previously published CDF measurement of Wgamma
boson production yields ATGC limits of -0.18 < lambda < 0.17 and -0.46 < Delta
kappa < 0.39 at the 95% confidence level, using a cut-off scale Lambda=1.5 TeV.Comment: 7 pages, 3 figures. Submitted to Phys. Rev.
Analysis of the Quantum Numbers of the X(3872) Particle
We present an analysis of angular distributions and correlations of the
X(3872) particle in the exclusive decay mode X(3872)->J/psi pi+ pi- with
J/psi->mu+ mu-. We use 780 pb -1 of data from ppbar collisions at sqrt{s} =
1.96 TeV collected with the CDF II detector at the Fermilab Tevatron. We derive
constraints on spin, parity, and charge conjugation parity of the X(3872)
particle by comparing measured angular distributions of the decay products with
predictions for different JPC hypotheses. The assignments JPC = 1++ and 2-+ are
the only ones consistent with the data.Comment: update to journal versio
Precision measurement of the top quark mass from dilepton events at CDF II
We report a measurement of the top quark mass, M_t, in the dilepton decay
channel of
using an integrated luminosity of 1.0 fb^{-1} of p\bar{p} collisions collected
with the CDF II detector. We apply a method that convolutes a leading-order
matrix element with detector resolution functions to form event-by-event
likelihoods; we have enhanced the leading-order description to describe the
effects of initial-state radiation. The joint likelihood is the product of the
likelihoods from 78 candidate events in this sample, which yields a measurement
of M_{t} = 164.5 \pm 3.9(\textrm{stat.}) \pm 3.9(\textrm{syst.})
\mathrm{GeV}/c^2, the most precise measurement of M_t in the dilepton channel.Comment: 7 pages, 2 figures, version includes changes made prior to
publication by journa
- …