1,054 research outputs found

    PAMELA, DAMA, INTEGRAL and Signatures of Metastable Excited WIMPs

    Full text link
    Models of dark matter with ~ GeV scale force mediators provide attractive explanations of many high energy anomalies, including PAMELA, ATIC, and the WMAP haze. At the same time, by exploiting the ~ MeV scale excited states that are automatically present in such theories, these models naturally explain the DAMA/LIBRA and INTEGRAL signals through the inelastic dark matter (iDM) and exciting dark matter (XDM) scenarios, respectively. Interestingly, with only weak kinetic mixing to hypercharge to mediate decays, the lifetime of excited states with delta < 2 m_e is longer than the age of the universe. The fractional relic abundance of these excited states depends on the temperature of kinetic decoupling, but can be appreciable. There could easily be other mechanisms for rapid decay, but the consequences of such long-lived states are intriguing. We find that CDMS constrains the fractional relic population of ~100 keV states to be <~ 10^-2, for a 1 TeV WIMP with sigma_n = 10^-40 cm^2. Upcoming searches at CDMS, as well as xenon, silicon, and argon targets, can push this limit significantly lower. We also consider the possibility that the DAMA excitation occurs from a metastable state into the XDM state, which decays via e+e- emission, which allows lighter states to explain the INTEGRAL signal due to the small kinetic energies required. Such models yield dramatic signals from down-scattering, with spectra peaking at high energies, sometimes as high as ~1 MeV, well outside the usual search windows. Such signals would be visible at future Ar and Si experiments, and may be visible at Ge and Xe experiments. We also consider other XDM models involving ~ 500 keV metastable states, and find they can allow lighter WIMPs to explain INTEGRAL as well.Comment: 22 pages, 7 figure

    12.グルタミン酸ナトリウムはglucagon like peptide-1の食後早期の分泌を促進し, 食後血糖の上昇を抑制する

    Get PDF
    The purpose of this study was to compare the growth and nutritional status of infants fed different diets, some of whom received a low-fat formula. Beginning at four to six months of age, 101 infants were fed whole cow\u27s milk, one of two low-fat follow-up formulas, or a standard infant formula until 12 months of age. Weight, recumbent length, and head circumference were measured at one-month intervals. Analyses of status (values at an age) for all examinations showed no significant differences among the feeding groups in status for weight or recumbent length, but there were significant differences in head circumference for boys and for girls after adjustments for the initial values. Head circumferences were smaller in those fed whole cow\u27s milk and relatively large in those fed follow-up formula, but these differences were small and not of clinical significance. Comparisons with national reference data showed growth in weight, recumbent length, and head circumference was normal regardless of feeding group. These results indicate that, during the second half year of infancy, the use of lower fat concentrations in the follow-up formulas did not retard growth in weight, recumbent length, or head circumference

    Population-Attributable Risk Estimates for Risk Factors Associated with Campylobacter Infection

    Get PDF
    In 2001-2002, a multicenter, prospective case-control study involving 1,714 participants ≥5 years of age was conducted in Australia to identify risk factors for Campylobacter infection. Adjusted population-attributable risks (PARs) were derived for eac

    Safety and Efficacy of Teduglutide in Pediatric Patients With Intestinal Failure due to Short Bowel Syndrome : A 24-Week, Phase III Study

    Get PDF
    Background This study evaluated the safety and efficacy of teduglutide in pediatric patients with short bowel syndrome-associated intestinal failure (SBS-IF). Methods A 24-week, phase III trial with 2 randomized, double-blind teduglutide dose groups and a nonblinded standard of care (SOC) arm was used; patients received 0.025 mg/kg or 0.05 mg/kg teduglutide once daily. Safety end points included treatment-emergent adverse events (TEAEs) and growth parameters. The primary efficacy/pharmacodynamic end point was the number of patients who achieved a >= 20% reduction in parenteral support (PS) from baseline at week 24. Results All 59 enrolled patients completed the study (0.025 mg/kg, n = 24; 0.05 mg/kg, n = 26; SOC, n = 9). Baseline demographics and disease characteristics were comparable among groups. TEAEs were reported by 98% and 100% of patients in the teduglutide and SOC groups, respectively. The most common TEAEs in the teduglutide-treated groups were pyrexia and vomiting. The primary end point was achieved by 13 (54.2%), 18 (69.2%), and 1 (11.1%) patients who received 0.025 mg/kg teduglutide, 0.05 mg/kg teduglutide, and SOC, respectively (P <0.05 vs SOC). Both 0.025-mg/kg and 0.05-mg/kg teduglutide groups showed clinically significant reductions in PS volume (P <0.05 vs SOC), PS calories, days per week and hours per day of PS infusions, and increases in enteral nutrition and plasma citrulline at week 24 compared with baseline. Two (8.3%, 0.025 mg/kg teduglutide) and 3 patients (11.5%, 0.05 mg/kg teduglutide) achieved enteral autonomy. Conclusion The safety profile of teduglutide was similar to that reported previously in children and adults. Treatment with teduglutide was associated with significant reductions in PS for pediatric patients with SBS-IF over 24 weeks.Peer reviewe

    Glyconanoparticles for colorimetric bioassays

    Get PDF
    Carbohydrate molecules are involved in many of the cellular processes that are important for life. By combining the specific analyte targeting of carbohydrates with the multivalent structure and change of solution colour as a consequence of plasmonic interactions with the aggregation of metal nanoparticles, glyconanoparticles have been used extensively for the development of bioanalytical assays. The noble metals used to create the nanocore, the methodologies used to assemble the carbohydrates on the nanoparticle surface, the carbohydrate chosen for each specific target, the length of the tether that separates the carbohydrate from the nanocore and the density of carbohydrates on the surface all impact on the structural formation of metal based glyconanoparticles. This tutorial review highlights these key components, which directly impact on the selectivity and sensitivity of the developed bioassay, for the colorimetric detection of lectins, toxins and viruses

    Safety Findings in Pediatric Patients During Long-Term Treatment With Teduglutide for Short-Bowel Syndrome-Associated Intestinal Failure : Pooled Analysis of 4 Clinical Studies

    Get PDF
    Background This analysis assessed combined safety data from 4 clinical studies of teduglutide in pediatric patients with short-bowel syndrome-associated intestinal failure (SBS-IF). Methods Safety data from teduglutide-treated patients in 4 clinical trials were pooled. The completed 12-week and 24-week phase 3 core studies (NCT01952080/EudraCT 2013-004588-30 and NCT02682381/EudraCT 2015-002252-27) enrolled children aged 1-17 years with SBS-IF. Patients could elect to enroll in ongoing open-label extensions (NCT02949362/EudraCT 2016-000863-17 and NCT02954458/EudraCT 2016-000849-30). Interim data from ongoing studies were included. Results Safety data are reported for 89 pediatric patients treated with teduglutide for a median (range) of 51.7 (5.0-94.7) weeks. Adverse events (AEs) were reported in all patients; the most common were vomiting (51.7%), pyrexia (43.8%), upper respiratory tract infection (41.6%), and cough (33.7%). Thirty-five patients (39.3%) had AEs considered related to teduglutide treatment; abdominal pain and vomiting were most frequent (5.6% each). Three serious AEs in 3 patients (3.4%) were considered related to teduglutide treatment: ileus, d-lactic acidosis, and gastrointestinal obstruction due to hard stools. All 3 events resolved. One cecal polyp was detected, which was not biopsied or found on repeat colonoscopy. No cases of neoplasia occurred. Conclusion Based on integrated data from 4 clinical studies, including long-term follow-up forPeer reviewe

    The HST/ACS Coma Cluster Survey. II. Data Description and Source Catalogs

    Full text link
    The Coma cluster was the target of a HST-ACS Treasury program designed for deep imaging in the F475W and F814W passbands. Although our survey was interrupted by the ACS instrument failure in 2007, the partially completed survey still covers ~50% of the core high-density region in Coma. Observations were performed for 25 fields that extend over a wide range of cluster-centric radii (~1.75 Mpc) with a total coverage area of 274 arcmin^2. The majority of the fields are located near the core region of Coma (19/25 pointings) with six additional fields in the south-west region of the cluster. In this paper we present reprocessed images and SExtractor source catalogs for our survey fields, including a detailed description of the methodology used for object detection and photometry, the subtraction of bright galaxies to measure faint underlying objects, and the use of simulations to assess the photometric accuracy and completeness of our catalogs. We also use simulations to perform aperture corrections for the SExtractor Kron magnitudes based only on the measured source flux and half-light radius. We have performed photometry for ~73,000 unique objects; one-half of our detections are brighter than the 10-sigma point-source detection limit at F814W=25.8 mag (AB). The slight majority of objects (60%) are unresolved or only marginally resolved by ACS. We estimate that Coma members are 5-10% of all source detections, which consist of a large population of unresolved objects (primarily GCs but also UCDs) and a wide variety of extended galaxies from a cD galaxy to dwarf LSB galaxies. The red sequence of Coma member galaxies has a constant slope and dispersion across 9 magnitudes (-21<M_F814W<-13). The initial data release for the HST-ACS Coma Treasury program was made available to the public in 2008 August. The images and catalogs described in this study relate to our second data release.Comment: Accepted for publication in ApJS. A high-resolution version is available at http://archdev.stsci.edu/pub/hlsp/coma/release2/PaperII.pd

    Outcomes from a 12-Week, Open-Label, Multicenter Clinical Trial of Teduglutide in Pediatric Short Bowel Syndrome

    Get PDF
    Objective To determine safety and pharmacodynamics/efficacy of teduglutide in children with intestinal failure associated with short bowel syndrome (SBS-IF). Study design This 12-week, open-label study enrolled patients aged 1-17 years with SBS-IF who required parenteral nutrition (PN) and showed minimal or no advance in enteral nutrition (EN) feeds. Patients enrolled sequentially into 3 teduglutide cohorts (0.0125 mg/kg/d [n = 8], 0.025 mg/kg/d [n = 14], 0.05 mg/kg/d [n = 15]) or received standard of care (SOC, n = 5). Descriptive summary statistics were used. Results All patients experienced ≥1 treatment-emergent adverse event; most were mild or moderate. No serious teduglutide-related treatment-emergent adverse events occurred. Between baseline and week 12, prescribed PN volume and calories (kcal/kg/d) changed by a median of −41% and −45%, respectively, with 0.025 mg/kg/d teduglutide and by −25% and −52% with 0.05 mg/kg/d teduglutide. In contrast, PN volume and calories changed by 0% and −6%, respectively, with 0.0125 mg/kg/d teduglutide and by 0% and −1% with SOC. Per patient diary data, EN volume increased by a median of 22%, 32%, and 40% in the 0.0125, 0.025, and 0.05 mg/kg/d cohorts, respectively, and by 11% with SOC. Four patients achieved independence from PN, 3 in the 0.05 mg/kg/d cohort and 1 in the 0.025 mg/kg/d cohort. Study limitations included its short-term, open-label design, and small sample size. Conclusions Teduglutide was well tolerated in pediatric patients with SBS-IF. Teduglutide 0.025 or 0.05 mg/kg/d was associated with trends toward reductions in PN requirements and advancements in EN feeding in children with SBS-IF

    The PAMELA Positron Excess from Annihilations into a Light Boson

    Full text link
    Recently published results from the PAMELA experiment have shown conclusive evidence for an excess of positrons at high (~ 10 - 100 GeV) energies, confirming earlier indications from HEAT and AMS-01. Such a signal is generally expected from dark matter annihilations. However, the hard positron spectrum and large amplitude are difficult to achieve in most conventional WIMP models. The absence of any associated excess in anti-protons is highly constraining on any model with hadronic annihilation modes. We revisit an earlier proposal, whereby the dark matter annihilates into a new light (<~GeV) boson phi, which is kinematically constrained to go to hard leptonic states, without anti-protons or pi0's. We find this provides a very good fit to the data. The light boson naturally provides a mechanism by which large cross sections can be achieved through the Sommerfeld enhancement, as was recently proposed. Depending on the mass of the WIMP, the rise may continue above 300 GeV, the extent of PAMELA's ability to discriminate electrons and positrons.Comment: 4 pages, 2 figures; v3 separated pions plot, references adde

    Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) Conceptual Design Report Volume 2: The Physics Program for DUNE at LBNF

    Full text link
    The Physics Program for the Deep Underground Neutrino Experiment (DUNE) at the Fermilab Long-Baseline Neutrino Facility (LBNF) is described
    corecore