54 research outputs found

    Accessing High Momentum States In Lattice QCD

    Get PDF
    Two measures are defined to evaluate the coupling strength of smeared interpolating operators to hadronic states at a variety of momenta. Of particular interest is the extent to which strong overlap can be obtained with individual high-momentum states. This is vital to exploring hadronic structure at high momentum transfers on the lattice and addressing interesting phenomena observed experimentally. We consider a novel idea of altering the shape of the smeared operator to match the Lorentz contraction of the probability distribution of the high-momentum state, and show a reduction in the relative error of the two-point function by employing this technique. Our most important finding is that the overlap of the states becomes very sharp in the smearing parameters at high momenta and fine tuning is required to ensure strong overlap with these states.Comment: 10 page

    Scalar mesons moving in a finite volume and the role of partial wave mixing

    Get PDF
    Phase shifts and resonance parameters can be obtained from finite-volume lattice spectra for interacting pairs of particles, moving with nonzero total momentum. We present a simple derivation of the method that is subsequently applied to obtain the pi pi and pi K phase shifts in the sectors with total isospin I=0 and I=1/2, respectively. Considering different total momenta, one obtains extra data points for a given volume that allow for a very efficient extraction of the resonance parameters in the infinite-volume limit. Corrections due to the mixing of partial waves are provided. We expect that our results will help to optimize the strategies in lattice simulations, which aim at an accurate determination of the scattering and resonance properties.Comment: 19 pages, 12 figure

    Reliability of two goniometric methods of measuring active inversion and eversion range of motion at the ankle

    Get PDF
    BACKGROUND: Active inversion and eversion ankle range of motion (ROM) is widely used to evaluate treatment effect, however the error associated with the available measurement protocols is unknown. This study aimed to establish the reliability of goniometry as used in clinical practice. METHODS: 30 subjects (60 ankles) with a wide variety of ankle conditions participated in this study. Three observers, with different skill levels, measured active inversion and eversion ankle ROM three times on each of two days. Measurements were performed with subjects positioned (a) sitting and (b) prone. Intra-class correlation coefficients (ICC([2,1])) were calculated to determine intra- and inter-observer reliability. RESULTS: Within session intra-observer reliability ranged from ICC([2,1] )0.82 to 0.96 and between session intra-observer reliability ranged from ICC([2,1] )0.42 to 0.80. Reliability was similar for the sitting and the prone positions, however, between sessions, inversion measurements were more reliable than eversion measurements. Within session inter-observer measurements in sitting were more reliable than in prone and inversion measurements were more reliable than eversion measurements. CONCLUSION: Our findings show that ankle inversion and eversion ROM can be measured with high to very high reliability by the same observer within sessions and with low to moderate reliability by different observers within a session. The reliability of measures made by the same observer between sessions varies depending on the direction, being low to moderate for eversion measurements and moderate to high for inversion measurements in both positions

    Is visual estimation of passive range of motion in the pediatric lower limb valid and reliable

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Visual estimation (VE) is an essential tool for evaluation of range of motion. Few papers discussed its validity in children orthopedics' practice. The purpose of our study was to assess validity and reliability of VE for passive range of motions (PROMs) of children's lower limbs.</p> <p>Methods</p> <p>Fifty typically developing children (100 lower limbs) were examined. Visual estimations for PROMs of hip (flexion, adduction, abduction, internal and external rotations), knee (flexion and popliteal angle) and ankle (dorsiflexion and plantarflexion) were made by a pediatric orthopaedic surgeon (POS) and a 5<sup>th </sup>year resident in orthopaedics. A last year medical student did goniometric measurements. Three weeks later, same measurements were performed to assess reliability of visual estimation for each examiner.</p> <p>Results</p> <p>Visual estimations of the POS were highly reliable for hip flexion, hip rotations and popliteal angle (ρ<sub>c </sub>≥ 0.8). Reliability was good for hip abduction, knee flexion, ankle dorsiflexion and plantarflexion (ρ<sub>c </sub>≥ 0.7) but poor for hip adduction (ρ<sub>c </sub>= 0.5). Reproducibility for all PROMs was verified. Resident's VE showed high reliability (ρ<sub>c </sub>≥ 0.8) for hip flexion and popliteal angle. Good correlation was found for hip rotations and knee flexion (ρ<sub>c </sub>≥ 0.7). Poor results were obtained for ankle PROMs (ρ<sub>c </sub>< 0.6) as well as hip adduction and abduction, the results of which not being reproducible. Influence of experience was clearly demonstrated for PROMs of hip rotations, adduction and abduction as well as ankle plantarflexion.</p> <p>Conclusion</p> <p>Accuracy of VE of passive hip flexion and knee PROMs is high regardless of the examiner's experience. Same accuracy can be found for hip rotations and abduction whenever VE is performed by an experienced examiner. Goniometric evaluation is recommended for passive hip adduction and for ankle PROMs.</p

    Non-invasive ventilation (NIV) as an aid to rehabilitation in acute respiratory disease

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Non-invasive ventilation (NIV) can increase exercise tolerance, reduce exercise induced desaturation and improve the outcome of pulmonary rehabilitation in patients with chronic respiratory disease. It is not known whether it can be applied to increase exercise capacity in patients admitted with non-hypercapnic acute exacerbations of COPD (AECOPD). We investigated the acceptability and feasibility of using NIV for this purpose.</p> <p>Methods</p> <p>On a single occasion, patients admitted with an acute exacerbation of chronic respiratory disease who were unable to cycle for five minutes at 20 watts attempted to cycle using NIV and their endurance time (T<sub>lim</sub>) was recorded. To determine feasibility of this approach in clinical practice patients admitted with AECOPD were screened for participation in a trial of regular NIV assisted rehabilitation during their hospital admission.</p> <p>Results</p> <p>In 12 patients tested on a single occasion NIV increased T<sub>lim </sub>from 184(65) seconds to 331(229) seconds (p = 0.04) and patients desaturated less (median difference = 3.5%, p = 0.029). In the second study, 60 patients were admitted to hospital during a three month period of whom only 18(30)% were eligible to participate and of these patients, only four (7%) consented to participate.</p> <p>Conclusion</p> <p>NIV improves exercise tolerance in patients with acute exacerbations of chronic respiratory disease but the applicability of this approach in routine clinical practice may be limited.</p> <p>Trial registration</p> <p><url>http://www.controlled-trials.com/ISRCTN35692743</url></p

    Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients.

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The aims of this study were to evaluate the construct validity (known group), concurrent validity (criterion based) and test-retest (intra-rater) reliability of manual goniometers to measure passive hip range of motion (ROM) in femoroacetabular impingement patients and healthy controls.</p> <p>Methods</p> <p>Passive hip flexion, abduction, adduction, internal and external rotation ROMs were simultaneously measured with a conventional goniometer and an electromagnetic tracking system (ETS) on two different testing sessions. A total of 15 patients and 15 sex- and age-matched healthy controls participated in the study.</p> <p>Results</p> <p>The goniometer provided greater hip ROM values compared to the ETS (range 2.0-18.9 degrees; <it>P </it>< 0.001); good concurrent validity was only achieved for hip abduction and internal rotation, with intraclass correlation coefficients (ICC) of 0.94 and 0.88, respectively. Both devices detected lower hip abduction ROM in patients compared to controls (<it>P </it>< 0.01). Test-retest reliability was good with ICCs higher 0.90, except for hip adduction (0.82-0.84). Reliability estimates did not differ between the goniometer and the ETS.</p> <p>Conclusions</p> <p>The present study suggests that goniometer-based assessments considerably overestimate hip joint ROM by measuring intersegmental angles (e.g., thigh flexion on trunk for hip flexion) rather than true hip ROM. It is likely that uncontrolled pelvic rotation and tilt due to difficulties in placing the goniometer properly and in performing the anatomically correct ROM contribute to the overrating of the arc of these motions. Nevertheless, conventional manual goniometers can be used with confidence for longitudinal assessments in the clinic.</p

    Efficacy of a multifaceted podiatry intervention to improve balance and prevent falls in older people: study protocol for a randomised trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Falls in older people are a major public health problem, with at least one in three people aged over 65 years falling each year. There is increasing evidence that foot problems and inappropriate footwear increase the risk of falls, however no studies have been undertaken to determine whether modifying these risk factors decreases the risk of falling. This article describes the design of a randomised trial to evaluate the efficacy of a multifaceted podiatry intervention to reduce foot pain, improve balance, and reduce falls in older people.</p> <p>Methods</p> <p>Three hundred community-dwelling men and women aged 65 years and over with current foot pain and an increased risk of falling will be randomly allocated to a control or intervention group. The "usual cae" control group will receive routine podiatry (i.e. nail care and callus debridement). The intervention group will receive usual care plus a multifaceted podiatry intervention consisting of: (i) prefabricated insoles customised to accommodate plantar lesions; (ii) footwear advice and assistance with the purchase of new footwear if current footwear is inappropriate; (iii) a home-based exercise program to strengthen foot and ankle muscles; and (iv) a falls prevention education booklet. Primary outcome measures will be the number of fallers, number of multiple fallers and the falls rate recorded by a falls diary over a 12 month period. Secondary outcome measures assessed six months after baseline will include the Medical Outcomes Study Short Form 12 (SF-12), the Manchester Foot Pain and Disability Index, the Falls Efficacy Scale International, and a series of balance and functional tests. Data will be analysed using the intention to treat principle.</p> <p>Discussion</p> <p>This study is the first randomised trial to evaluate the efficacy of podiatry in improving balance and preventing falls. The trial has been pragmatically designed to ensure that the findings can be generalised to clinical practice. If found to be effective, the multifaceted podiatry intervention will be a unique addition to common falls prevention strategies already in use.</p> <p>Trial registration</p> <p>Australian New Zealand Clinical Trials Registry: ACTRN12608000065392</p

    QCD and strongly coupled gauge theories : challenges and perspectives

    Get PDF
    We highlight the progress, current status, and open challenges of QCD-driven physics, in theory and in experiment. We discuss how the strong interaction is intimately connected to a broad sweep of physical problems, in settings ranging from astrophysics and cosmology to strongly coupled, complex systems in particle and condensed-matter physics, as well as to searches for physics beyond the Standard Model. We also discuss how success in describing the strong interaction impacts other fields, and, in turn, how such subjects can impact studies of the strong interaction. In the course of the work we offer a perspective on the many research streams which flow into and out of QCD, as well as a vision for future developments.Peer reviewe

    Are clinical measures of foot posture and mobility associated with foot kinematics when walking?

    Get PDF
    Background: There is uncertainty as to which foot posture measures are the most valid in terms of predicting kinematics of the foot. The aim of this study was to investigate the associations of clinical measures of static foot posture and mobility with foot kinematics during barefoot walking. Method: Foot posture and mobility were measured in 97 healthy adults (46 males, 51 females; mean age 24.4 ± 6.2 years). Foot posture was assessed using the 6-item Foot Posture Index (FPI), Arch Index (AI), Normalised Navicular Height (NNHt) and Normalised Dorsal Arch Height (DAH). Foot mobility was evaluated using the Foot Mobility Magnitude (FMM) measure. Following this, a five-segment foot model was used to measure tri-planar motion of the rearfoot, midfoot, medial forefoot, lateral forefoot and hallux. Peak and range of motion variables during load acceptance and midstance/propulsion phases of gait were extracted for all relative segment to segment motion calculations. Hierarchical regression analyses were conducted, adjusting for potential confounding variables. Results: The degree of variance in peak and range of motion kinematic variables that was independently explained by foot posture measures was as follows: FPI 5 to 22 %, NNHt 6 to 20 %, AI 7 to 13 %, DAH 6 to 8 %, and FMM 8 %. The FPI was retained as a significant predictor across the most number of kinematic variables. However, the amount of variance explained by the FPI for individual kinematic variables did not exceed other measures. Overall, static foot posture measures were more strongly associated with kinematic variables than foot mobility measures and explained more variation in peak variables compared to range of motion variables. Conclusions: Foot posture measures can explain only a small amount of variation in foot kinematics. Static foot posture measures, and in particular the FPI, were more strongly associated with foot kinematics compared with foot mobility measures. These findings suggest that foot kinematics cannot be accurately inferred from clinical observations of foot posture alone
    corecore