27 research outputs found
Electropolymerised molecularly imprinted polymers for the heat-transfer based detection of microorganisms: A proof-of-concept study using yeast
In this contribution, molecularly imprinted polymers (MIPs) were electropolymerised onto screen-printed carbon electrodes (SPCEs) to develop specific sensors for thermal detection of yeast. A laboratory yeast strain free of interferents was used to optimise the polymerisation procedure, whereas yeast in a complex mixture (yeast for baking) was employed to produce the final sensors and demonstrate proof-of-application. Two different electropolymerisation methods were employed, cyclic voltammetry and chronoamperometry respectively; the electrochemical methodology allows for controlled deposition and the ability to tailor the polymer surface to the required application. Infrared spectroscopy and scanning electron microscopy confirmed that the methods led to different structures; with cyclic voltammetry a high surface area was achieved, whereas for chronoamperometry a dense film was formed. Subsequently, these functionalised electrodes were inserted into a home-made thermal device that can measure the selective binding of yeast cells to the MIP layer via monitoring the thermal resistance (R ) at the solid–liquid interface. The results of the measurements showed that MIP-functionalised electrodes produced, according to both methods, a significant response in thermal signal for the MIP-functionalised electrode, which was not the case for the reference Non-Imprinted Polymer (NIP)-functionalised electrode. This demonstrated that thermal analysis can be employed for the detection of yeast, even in a complex sample such as food. To our knowledge, this is the first report of MIPs electropolymerised onto screen-printed electrodes for the thermal detection of fungi. The proposed approach enables the fast production of low-cost electrodes using a simple manufacturing procedure compatible with a portable device, implying high commercial potential. In the future, this could be adapted to a broad range of microorganisms including bacteria. t
Développement de capteur électrochimique pour la détection de micropolluants prioritaires
Electrochemical sensor based on functionalized carbon materials, for the detection of two micropollutants, lead and anthracene, which are among of the priority substances of the European Framework Directive on Water(DCE 2000/60 / EC). Electrochemical sensors allow to achieve detection limits and selectivities for the analysis of micropollutants whose concentrations are of the order of μg/L. They are easy to use for in situ analyzes at lower costs compared to those of the conventional analysis equipment. Their robustness is an important parameter in order to allow continuous or semi-continuous measurements in water. First of all, this thesis proposes the development of a sensor for lead detection. The conductive carbon ink formulation is studied for the screen-printing of the receiving electrode, thus allowing to control the ink composition and to study the influence of the carbon phase on the electrocatalytic properties of electrodes. Functionalization of electrodes by electrochemical grafting of a diazonium salt is also studied in order to control the sensitivity and reproducibility of grafted electrodes, by controlling the thickness and the quality of the layers. With this aim it has been studied the functionalization in a protic ionic liquid in order to allow the control of the monolayer bymodulating the viscosity of this medium. The grafted electrodes show improved analytical performance especially in terms of repeatability and reproducibility. Finally, this work reports the development of a sensor for the electrochemical detection of anthracene, a molecule without chemical functions. In this case, a molecularly imprinted polymer, a material known for its very high selectivity, functionalizes the electrodes.Having a selectivity is only based on the form factor of the molecule, the performance of the sensor developed for the detection of anthracene is also highlighted.Capteur électrochimique basé sur des matériaux carbonés fonctionnalisés, pour la détection de deux micropolluants faisant partie des substances prioritaires de la Directive Cadre européenne sur l’Eau (DCE2000/60/CE) : le plomb et l’anthracène. Les capteurs électrochimiques permettent d’atteindre des limites de détection et une sélectivité adéquates pour l’analyse de micropolluants dont les concentrations sont de l’ordredu μg/L, et sont simples d’utilisation pour des analyses in situ à moindre coût comparés aux appareils d’analyses conventionnels. Leur robustesse est un paramètre important afin de permettre des mesures en continu ou semi-continu dans les eaux. Cette thèse propose tout d’abord le développement du capteur pour la détection du plomb. La formulation d’une encre conductrice de carbone est étudiée pour la sérigraphie de ’électrode réceptrice, permettant ainsi de contrôler la composition de l’encre et d’étudier l’influence de la phase carbonée sur les propriétés électrocatalytiques des électrodes. La fonctionnalisation des électrodes par greffage électrochimique d’un sel de diazonium est également étudiée afin de maîtriser la sensibilité et la reproductibilité des électrodes greffées, en contrôlant l’épaisseur et la qualité des couches. Avec cet objectif, la fonctionnalisation dans un liquide ionique protique qui permet le contrôle de la monocouche en modulant la viscosité de ce milieu a été étudiée. Les électrodes greffées montrent des performances analytiques améliorées notamment en termes de répétabilité et de reproductibilité. Enfin ce travail de thèse porte également sur le développement du capteur pour la détection électrochimique de l’anthracène, molécule sans fonctions chimiques. Les électrodes sont, dans ce cas, fonctionnalisées par un polymère à empreinte moléculaire, matériau connu pour sa très grande sélectivité. Les performances de ce capteur, dont la sélectivité est basée uniquement sur le facteur de forme de la molécule, pour la détection de l’anthracène sont alors mises en évidence
Développement de capteur électrochimique pour la détection de micropolluants prioritaires
Electrochemical sensor based on functionalized carbon materials, for the detection of two micropollutants, lead and anthracene, which are among of the priority substances of the European Framework Directive on Water(DCE 2000/60 / EC). Electrochemical sensors allow to achieve detection limits and selectivities for the analysis of micropollutants whose concentrations are of the order of μg/L. They are easy to use for in situ analyzes at lower costs compared to those of the conventional analysis equipment. Their robustness is an important parameter in order to allow continuous or semi-continuous measurements in water. First of all, this thesis proposes the development of a sensor for lead detection. The conductive carbon ink formulation is studied for the screen-printing of the receiving electrode, thus allowing to control the ink composition and to study the influence of the carbon phase on the electrocatalytic properties of electrodes. Functionalization of electrodes by electrochemical grafting of a diazonium salt is also studied in order to control the sensitivity and reproducibility of grafted electrodes, by controlling the thickness and the quality of the layers. With this aim it has been studied the functionalization in a protic ionic liquid in order to allow the control of the monolayer bymodulating the viscosity of this medium. The grafted electrodes show improved analytical performance especially in terms of repeatability and reproducibility. Finally, this work reports the development of a sensor for the electrochemical detection of anthracene, a molecule without chemical functions. In this case, a molecularly imprinted polymer, a material known for its very high selectivity, functionalizes the electrodes.Having a selectivity is only based on the form factor of the molecule, the performance of the sensor developed for the detection of anthracene is also highlighted.Capteur électrochimique basé sur des matériaux carbonés fonctionnalisés, pour la détection de deux micropolluants faisant partie des substances prioritaires de la Directive Cadre européenne sur l’Eau (DCE2000/60/CE) : le plomb et l’anthracène. Les capteurs électrochimiques permettent d’atteindre des limites de détection et une sélectivité adéquates pour l’analyse de micropolluants dont les concentrations sont de l’ordredu μg/L, et sont simples d’utilisation pour des analyses in situ à moindre coût comparés aux appareils d’analyses conventionnels. Leur robustesse est un paramètre important afin de permettre des mesures en continu ou semi-continu dans les eaux. Cette thèse propose tout d’abord le développement du capteur pour la détection du plomb. La formulation d’une encre conductrice de carbone est étudiée pour la sérigraphie de ’électrode réceptrice, permettant ainsi de contrôler la composition de l’encre et d’étudier l’influence de la phase carbonée sur les propriétés électrocatalytiques des électrodes. La fonctionnalisation des électrodes par greffage électrochimique d’un sel de diazonium est également étudiée afin de maîtriser la sensibilité et la reproductibilité des électrodes greffées, en contrôlant l’épaisseur et la qualité des couches. Avec cet objectif, la fonctionnalisation dans un liquide ionique protique qui permet le contrôle de la monocouche en modulant la viscosité de ce milieu a été étudiée. Les électrodes greffées montrent des performances analytiques améliorées notamment en termes de répétabilité et de reproductibilité. Enfin ce travail de thèse porte également sur le développement du capteur pour la détection électrochimique de l’anthracène, molécule sans fonctions chimiques. Les électrodes sont, dans ce cas, fonctionnalisées par un polymère à empreinte moléculaire, matériau connu pour sa très grande sélectivité. Les performances de ce capteur, dont la sélectivité est basée uniquement sur le facteur de forme de la molécule, pour la détection de l’anthracène sont alors mises en évidence
Electrochemical sensor development for the detection of priority micropollutants
Capteur électrochimique basé sur des matériaux carbonés fonctionnalisés, pour la détection de deux micropolluants faisant partie des substances prioritaires de la Directive Cadre européenne sur l’Eau (DCE2000/60/CE) : le plomb et l’anthracène. Les capteurs électrochimiques permettent d’atteindre des limites de détection et une sélectivité adéquates pour l’analyse de micropolluants dont les concentrations sont de l’ordredu μg/L, et sont simples d’utilisation pour des analyses in situ à moindre coût comparés aux appareils d’analyses conventionnels. Leur robustesse est un paramètre important afin de permettre des mesures en continu ou semi-continu dans les eaux. Cette thèse propose tout d’abord le développement du capteur pour la détection du plomb. La formulation d’une encre conductrice de carbone est étudiée pour la sérigraphie de ’électrode réceptrice, permettant ainsi de contrôler la composition de l’encre et d’étudier l’influence de la phase carbonée sur les propriétés électrocatalytiques des électrodes. La fonctionnalisation des électrodes par greffage électrochimique d’un sel de diazonium est également étudiée afin de maîtriser la sensibilité et la reproductibilité des électrodes greffées, en contrôlant l’épaisseur et la qualité des couches. Avec cet objectif, la fonctionnalisation dans un liquide ionique protique qui permet le contrôle de la monocouche en modulant la viscosité de ce milieu a été étudiée. Les électrodes greffées montrent des performances analytiques améliorées notamment en termes de répétabilité et de reproductibilité. Enfin ce travail de thèse porte également sur le développement du capteur pour la détection électrochimique de l’anthracène, molécule sans fonctions chimiques. Les électrodes sont, dans ce cas, fonctionnalisées par un polymère à empreinte moléculaire, matériau connu pour sa très grande sélectivité. Les performances de ce capteur, dont la sélectivité est basée uniquement sur le facteur de forme de la molécule, pour la détection de l’anthracène sont alors mises en évidence.Electrochemical sensor based on functionalized carbon materials, for the detection of two micropollutants, lead and anthracene, which are among of the priority substances of the European Framework Directive on Water(DCE 2000/60 / EC). Electrochemical sensors allow to achieve detection limits and selectivities for the analysis of micropollutants whose concentrations are of the order of μg/L. They are easy to use for in situ analyzes at lower costs compared to those of the conventional analysis equipment. Their robustness is an important parameter in order to allow continuous or semi-continuous measurements in water. First of all, this thesis proposes the development of a sensor for lead detection. The conductive carbon ink formulation is studied for the screen-printing of the receiving electrode, thus allowing to control the ink composition and to study the influence of the carbon phase on the electrocatalytic properties of electrodes. Functionalization of electrodes by electrochemical grafting of a diazonium salt is also studied in order to control the sensitivity and reproducibility of grafted electrodes, by controlling the thickness and the quality of the layers. With this aim it has been studied the functionalization in a protic ionic liquid in order to allow the control of the monolayer bymodulating the viscosity of this medium. The grafted electrodes show improved analytical performance especially in terms of repeatability and reproducibility. Finally, this work reports the development of a sensor for the electrochemical detection of anthracene, a molecule without chemical functions. In this case, a molecularly imprinted polymer, a material known for its very high selectivity, functionalizes the electrodes.Having a selectivity is only based on the form factor of the molecule, the performance of the sensor developed for the detection of anthracene is also highlighted
Surface modifications in protic ionic liquids: Application to water monitoring
International audienc
Surface modifications in protic ionic liquid: application to water monitoring
International audienc
Surface modifications in protic ionic liquid: application to water monitoring
International audienc
Formulation d'encres de carbone pour la sérigraphie d'électrodes appliquées à la détection électrochimique de micropolluants prioritaires et émergents
National audienc
Modifications de surface en milieu liquide ionique protique: Application aux capteurs électrochimiques
National audienc
Élaboration d'électrodes carbonées sérigraphiées pour la détection de micropolluants en milieux aqueux
National audienc