216 research outputs found

    Explore: Moon Lights the Way

    Get PDF

    The Future of NASA at the Kennedy Space Center

    Get PDF
    No abstract availabl

    Resistivity inversion in 2-D anisotropic media: numerical experiments

    Get PDF
    Many rocks and layered/fractured sequences have a clearly expressed electrical anisotropy although it is rare in practice to incorporate anisotropy into resistivity inversion. In this contribution, we present a series of 2.5-D synthetic inversion experiments for various electrode configurations and 2-D anisotropic models. We examine and compare the image reconstructions obtained using the correct anisotropic inversion code with those obtained using the false but widely used isotropic assumption. Superior reconstruction in terms of reduced data misfit, true anomaly shape and position, and anisotropic background parameters were obtained when the correct anisotropic assumption was employed for medium to high coefficients of anisotropy. However, for low coefficient values the isotropic assumption produced better-quality results. When an erroneous isotropic inversion is performed on medium to high level anisotropic data, the images are dominated by patterns of banded artefacts and high data misfits. Various pole-pole, pole-dipole and dipole-dipole data sets were investigated and evaluated for the accuracy of the inversion result. The eigenvalue spectra of the pseudo-Hessian matrix and the formal resolution matrix were also computed to determine the information content and goodness of the results. We also present a data selection strategy based on high sensitivity measurements which drastically reduces the number of data to be inverted but still produces comparable results to that of the comprehensive data set. Inversion was carried out using transversely isotropic model parameters described in two different co-ordinate frames for the conductivity tensor, namely Cartesian versus natural or eigenframe. The Cartesian frame provided a more stable inversion product. This can be simply explained from inspection of the eigenspectra of the pseudo-Hessian matrix for the two model description

    Preoperative staging of non-small-cell lung cancer: comparison of whole-body diffusion-weighted magnetic resonance imaging and 18F-fluorodeoxyglucose-positron emission tomography/computed tomography

    Get PDF
    Objective: To investigate the diagnostic value of whole-body magnetic resonance imaging (MRI) including diffusion-weighted imaging with background signal suppression (DWIBS) for preoperative assessment of non-small-cell lung cancer (NSCLC) in comparison to 18F-fluorodeoxyglucose 18FDG) positron emission tomography/computed tomography (PET/CT). Methods: Thirty-three patients with suspected NSCLC were enrolled. Patients were examined before surgery with PET/CT and whole-body MRI including T1-weighted turbo spin echo (TSE), T2-weighted short tau inversion recovery (STIR) and DWIBS sequences (b = 0/800). Histological or cytological specimens were taken as standard of reference. Results: Whole-body MRI with DWIBS as well as PET/CT provided diagnostic image quality in all cases. Sensitivity for primary tumour detection: MRI 93%, PET/CT 98%. T-staging accuracy: MRI 63%, PET/CT 56%. N-staging accuracy: MRI 66%, PET/CT 71%. UICC staging accuracy: MRI 66%, PET/CT 74%. Sensitivity for metastatic involvement of individual lymph node groups: MRI 44%, PET/CT 47%. Specificity for individual non-metastatic lymph node groups: MRI 93%, PET/CT 96%. Assessment accuracy for individual lymph node groups: MRI 85%, PET/CT 88%. Observer agreement rate for UICC staging: MRI 74%, PET/CT 90%. Conclusion: Whole-body MRI with DWIBS provides comparable results to PET/CT in staging of NSCLC, but shows no superiority. Most relevant challenges for both techniques are T-staging accuracy and sensitivity for metastatic lymph node involvement. Key Points : ‱ Numerous radiological methods are available for the crucial staging of lung cancer ‱ Whole-body DWIBS MRI provides comparable results to PET/CT in NSCLC staging. ‱ No evident superiority of whole-body DWIBS over PET/CT in NSCLC staging. ‱ Challenges for both techniques are T-staging and detection of small metastase

    Sequence and functional characterization of hypoxia inducible factors, HIF1α, HIF2αa, and HIF3α, from the estuarine fish, Fundulus heteroclitus

    Get PDF
    Author Posting. © The Author(s), 2016. This is the author's version of the work. It is posted here under a nonexclusive, irrevocable, paid-up, worldwide license granted to WHOI. It is made available for personal use, not for redistribution. The definitive version was published in American Journal of Physiology-Regulatory Integrative and Comparative Physiology, 312 (2017): R412-R425, doi:10.1152/ajpregu.00402.2016.The hypoxia inducible factor (HIF) family of transcription factors plays central roles in the development, physiology, pathology, and environmental adaptation of animals. Because many aquatic habitats are characterized by episodes of low dissolved oxygen, fish represent ideal models to study the roles of HIF in the response to aquatic hypoxia. The estuarine fish Fundulus heteroclitus occurs in habitats prone to hypoxia, it responds to low oxygen via behavioral, physiological, and molecular changes, and one member of the HIF family, HIF2α, has been previously described. Herein, cDNA sequencing, phylogenetic analyses, and genomic approaches were used to determine other members of the HIFα family from F. heteroclitus and their relationships to HIFα subunits from other vertebrates. In vitro and cellular approaches demonstrated that full-length forms of HIF1α, 2α, and 3α independently formed complexes with the ÎČ subunit (ARNT) to bind to hypoxia response elements and activate reporter gene expression. Quantitative PCR showed that HIFα mRNA abundance varied among organs of normoxic fish in an isoform-specific fashion. Analysis of the F. heteroclitus genome revealed a locus encoding a second HIF2α, HIF2αb, a predicted protein lacking oxygen sensing and transactivation domains. Finally, sequence analyses demonstrated polymorphism in the coding sequence of each F. heteroclitus HIFα subunit, suggesting that genetic variation in these transcription factors may play a role in the variation in hypoxia responses among individuals or populations.This research was supported in part by the National Science Foundation (IBN-0236494 and DEB-1120263) and by National Institute of Environmental Health Sciences (NIEHS) grant P42ES007381 (Superfund Basic Research Program at Boston University). Data interpretation was aided by reference to a preliminary draft of the F. heteroclitus genome sequence, which was supported by funding from the National Science Foundation (collaborative research grants DEB-1120512, DEB-1265282, DEB-1120013, DEB-1120263, DEB-1120333, DEB-1120398)

    Actuation and stiffening in fluid-driven soft robots using low-melting-point material

    Get PDF
    Soft material robots offer a number of advantages over traditional rigid robots in applications including human-robot interaction, rehabilitation and surgery. These robots can navigate around obstacles, elongate, squeeze through narrow openings or be squeezed - and they are considered to be inherently safe. The ability to stiffen compliant soft actuators has been achieved by embedding various mechanisms that are generally decoupled from the actuation principle. Miniaturisation becomes challenging due to space limitations which can in turn result in diminution of stiffening effects. Here, we propose to hydraulically actuate soft manipulators with low-melting-point material and, at the same time, be able to switch between a soft and stiff state. Instead of allocating an additional stiffening chamber within the soft robot, one chamber only is used for actuation and stiffening. Low Melting Point Alloy is integrated into the actuation chamber of a single-compartment soft robotic manipulator and the interfaced robotic syringe pump. Temperature change is enabled through embedded nichrome wires. Our experimental results show higher stiffness factors, from 9-12 opposing the motion of curvature, than those previously found for jamming mechanisms incorporated in separate additional chambers, in the range of 2-8 for the same motion

    The significance of hazardous chemicals in wastewater treatment works effluents

    Get PDF
    This is the post-print version of the final paper published in Science of The Total Environment. The published article is available from the link below. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. Copyright @ 2012 Elsevier B.V.The advent of increasingly stringent and wider ranging European Union legislation relating to water and the environment has required regulators to assess compliance risk and to respond by formulating appropriate pollution control measures. To support this process the UK Water Industry has completed a national Chemicals Investigation Programme (CIP), to monitor over 160 wastewater treatment works (WwTWs) for 70 determinands. Final effluent concentrations of zinc, polynuclear aromatic hydrocarbons (fluoranthene, benzo(a)pyrene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(g,h,i)perylene and indeno(1,2,3-cd)pyrene), “penta” congeners (BDEs) 47 and 99, tributyltin, triclosan, erythromycin, oxytetracycline, ibuprofen, propranolol, fluoxetine, diclofenac, 17ÎČ-estradiol and 17α-ethinyl estradiol exceeded existing or proposed Environmental Quality Standards (EQSs) in over 50% of WwTWs. Dilution by receiving water might ensure compliance with EQSs for these chemicals, apart from the BDEs. However, in some cases there will be insufficient dilution to ensure compliance and additional management options may be required

    PD-1+ natural killer cells in human non-small cell lung cancer can be activated by PD-1/PD-L1 blockade

    Get PDF
    Natural killer (NK) cells are critically involved in anti-tumor immunity by targeting tumor cells. In this study, we show that intratumoral NK cells from NSCLC patients expressed elevated levels of the immune checkpoint receptor PD-1 on their cell surface. In contrast to the expression of activating receptors, PD-1; +; NK cells co-expressed more inhibitory receptors compared to PD-1; -; NK cells. Intratumoral NK cells were less functional compared to peripheral NK cells, and this dysfunction correlated with PD-1 expression. Tumor cells expressing PD-L1 inhibited the functionality of PD-1; +; NK cells in ex vivo models and induced PD-1 clustering at the immunological synapse between NK cells and tumor cells. Notably, treatment with PD-1 blockade was able to reverse PD-L1-mediated inhibition of PD-1; +; NK cells. Our findings highlight the therapeutic potential of PD-1; +; NK cells in immune checkpoint blockade and could guide the development of NK cell-stimulating agents in combination with PD-1 blockade

    Real-time simulation of dissipation-driven quantum systems

    Get PDF
    We set up a real-time path integral to study the evolution of quantum systems driven in real-time completely by the coupling of the system to the environment. For specifically chosen interactions, this can be interpreted as measurements being performed on the system. For a spin-1/2 system, in particular, when the measurement results are averaged over, the resulting sign problem completely disappears, and the system can be simulated with an efficient cluster algorithm

    Functional results after chest wall stabilization with a new screwless fixation device

    Get PDF
    OBJECTIVES This is the experience with the Stratos system in two surgical centres for the management of two types of rib fractures: flail chest and multiple dislocated rib fractures with significant chest wall deformity. METHODS From January 2009 to May 2012, 94 consecutive patients were included. Selected indications were extended anterolateral flail chest (n = 68) and dislocated painful rib fractures (n = 26). The open reduction internal fixation (ORIF) system consists of flexible titanium rib clamps and connecting plates. The postoperative course was assessed. Clinical and functional outcomes were evaluated at 6 months. Functional assessment consisted of measurement of the functional vital capacity (FVC) and magnetic resonance imaging (MRI) examination with determination of the radiological vital capacity (rVC) in patients with a flail chest. RESULTS The median operation time and length of hospital stay were 122 min and 19 days, respectively, in patients with a flail chest, and 67 min and 11 days, respectively, in patients with dislocated painful rib fractures. The morbidity rate was 6.4% and the overall 30-day mortality rate was 1.1%. Clinical evaluation and pulmonary function testing at 6 months revealed no deformity of the chest wall, symmetrical shoulder girdle mobility in 88% and a feeling of stiffness on the operated side in 19% of the patients operated for a flail chest. Median ratio of FVC was 88%, not suggesting any restriction after stabilization. MRI was performed in 53% (36 of 68) of the patients with a flail chest. The analysis of the rVC showed, on average, no clinically relevant restriction related to the operation, with a mean rVC of the operated relative to the non-operated side of 92% (95% confidence interval: 83, 100). Stabilization of more than four ribs was associated with a lower median rVC than stabilization of four or less ribs. CONCLUSIONS Our results suggest that stabilization of the chest wall with this screwless rib fixation device can be performed with a low morbidity and lead to early restoration of chest wall integrity and respiratory pump function, without clinically relevant functional restriction. Owing to the simplicity of the fixation technique, indications for stabilization can be safely enlarged to selected patients with dislocated and painful rib fracture
    • 

    corecore