28 research outputs found

    Posterior Decompression and Fusion: Whole-Spine Functional and Clinical Outcomes

    Get PDF
    The mobility of the spine and the change in the angle of the curvatures are directly related to spinal pain and spinal stenosis. The aim of the study was the evaluation of morphology and mobility of the spine in patients who were subjected to decompression and posterior fusion with pedicle screws. The treatment group consisted of 20 patients who underwent posterior fixation of lumbar spine (one and two level fusion). The control group consisted of 39 healthy subjects. Mobility and curvatures of the spine were measured with a non-invasive device, the Spinal Mouse. Pain was evaluated with the Visual Analogue Scale (VAS). The Oswestry Disability Index (ODI) and the SF-36 were used to evaluate the degree of the functional disability and the quality of life, respectively. The measurements were recorded preoperatively and at 3, 6 and 12 months postoperatively. The mobility of the lumbar spine in the sagittal plane increased (p = 0.009) at 12 months compared to the measurements at 3 months. The mobility of the thoracic spine in the frontal plane increased (p = 0.009) at 12 months compared to the preoperative evaluation. The results of VAS, ODI and SF-36 PCS improved significantly (p<0.001). The levels of fusion exhibited a strong linear correlation (r = 0.651, p = 0.002) with the total trunk inclination in the upright position. Although pain, quality of life and spinal mobility in the sagittal and frontal planes significantly improved in the treatment group, these patients still had limited mobility and decreased curves/angles values compared to control group

    SOSORT 2012 consensus paper: reducing x-ray exposure in pediatric patients with scoliosis

    Get PDF
    This 2012 Consensus paper reviews the literature on side effects of x-ray exposure in the pediatric population as it relates to scoliosis evaluation and treatment. Alternative methods of spinal assessment and imaging are reviewed, and strategies for reducing the number of radiographs are developed. Using the Delphi technique, SOSORT members developed consensus statements that describe how often radiographs should be taken in each of the pediatric and adolescent sub-populations

    Efficacy and safety of VEPTR instrumentation for progressive spine deformities in young children without rib fusions

    No full text
    This retrospective study analyses 23 children treated with vertical expandable prosthetic titanium rib (VEPTR) for correction of non-congenital early onset spine deformities. After the index procedure (IP), the device was lengthened at 6-month intervals. The average (av) age at the time of IP was 6.5 years (1.11–10.5). The av follow-up time was 3.6 years (2–5.8). Diagnosis included 1 early onset idiopathic scoliosis, 11 neuromuscular, 2 post-thoracotomy scoliosis, 1 Sprengel deformity, 2 hyperkyphosis, 1 myopathy and 5 syndromic. Surgeries (187) included 23 IPs, av 6.5 (4–10) device expansions per patient (149) and 15 unplanned surgeries. 23 complications (0.13 per surgery) included 10 skin sloughs, 5 implant dislocations, 2 rod breakages and 6 infections. Coronal Cobb angle was av 68° (11°–111°), at follow-up av 54° (0°–105°). Pelvic obliquity was av 33° (13°–60°), at follow-up av 16° (0°–42°). T1 tilt was av 29° (5°–84°), two remained unchanged, the remainder improved 10°–68°. Sagittal plane: All but two had stable profiles, two hyperkyphosis of 110°/124° improved to 56°/86°. Space available for lung ratio was less than 90% in ten before the IP, improved in nine and deteriorated in one. Originally designed for thoracic insufficiency syndromes related to rib and vertebral anomalies, VEPTR proved to be a valuable alternative to dual growing rods for non-congenital early onset spine deformities. The complication rate was lower, the control of the sagittal plane and the pelvic obliquity was as good, but the correction of the coronal plane deformity was less than growing rods. However, VEPTR’s spine-sparing approach might provoke less spontaneous spinal fusion and ease the final correction at maturity

    The role of routine magnetic resonance imaging in the preoperative evaluation of adolescent idiopathic scoliosis

    No full text
    The routine use of magnetic resonance imaging (MRI) in adolescent idiopathic scoliosis remains controversial, and current indications for MRI in idiopathic scoliosis vary from study to study. The purpose of this study was to demonstrate the prevalence of neural axis malformations and the clinical relevance of routine MRI studies in the evaluation of patients with adolescent idiopathic scoliosis undergoing surgical intervention without any neurological findings. A total of 249 patients with a diagnosis of idiopathic scoliosis were treated surgically between the years 2002 and 2007. A routine whole spine MRI analysis was performed in all patients. On the preoperative clinical examination, all patients were neurologically intact. There were 20 (8%) patients (3 males and 17 females) who had neural axis abnormalities on MRI. Three of those 20 patients needed additional neurosurgical procedures before corrective surgery; the remaining underwent corrective spinal surgery without any neurosurgical operations. Magnetic resonance imaging may be beneficial for patients with presumed idiopathic scoliosis even in the absence of neurological findings and it is ideally performed from the level of the brainstem to the sacrum
    corecore