1,679 research outputs found

    Solid-phase extraction and purification of membrane proteins using a UV-modified PMMA microfluidic bioaffinity mu SPE device

    Get PDF
    We present a novel microfluidic solid-phase extraction (??SPE) device for the affinity enrichment of biotinylated membrane proteins from whole cell lysates. The device offers features that address challenges currently associated with the extraction and purification of membrane proteins from whole cell lysates, including the ability to release the enriched membrane protein fraction from the extraction surface so that they are available for downstream processing. The extraction bed was fabricated in PMMA using hot embossing and was comprised of 3600 micropillars. Activation of the PMMA micropillars by UV/O3 treatment permitted generation of surface-confined carboxylic acid groups and the covalent attachment of NeutrAvidin onto the ??SPE device surfaces, which was used to affinity select biotinylated MCF-7 membrane proteins directly from whole cell lysates. The inclusion of a disulfide linker within the biotin moiety permitted release of the isolated membrane proteins via DTT incubation. Very low levels (???20 fmol) of membrane proteins could be isolated and recovered with ???89% efficiency with a bed capacity of 1.7 pmol. Western blotting indicated no traces of cytosolic proteins in the membrane protein fraction as compared to significant contamination using a commercial detergent-based method. We highlight future avenues for enhanced extraction efficiency and increased dynamic range of the ??SPE device using computational simulations of different micropillar geometries to guide future device designs.close2

    Effects of adding Tiotropium or Aclidinium as triple therapy using impulse oscillometry in COPD

    Get PDF
    INTRODUCTION: Long-acting muscarinic antagonists confer improvements in spirometry when used in addition to inhaled corticosteroids and long-acting beta-agonists (ICS/LABA) in COPD. The dual objectives of this proof of concept study were to evaluate trough effects of tiotropium (TIO) or aclidinium (ACL) when used as triple therapy and to assess if impulse oscillometry (IOS) might be more sensitive than spirometry in detecting subtle differences in bronchodilator response. METHODS: Patients with moderate to severe COPD already taking ICS/LABA were randomized to receive add-on therapy in cross-over fashion with either TIO 18 ”g od or ACL 322 ”g bid for 2–3 weeks each. Measurements of IOS, spirometry, 6-min walk test, St George’s Respiratory Questionnaire (SGRQ) and Baseline/Transition Dyspnoea Index (TDI) were made at baseline and after chronic dosing at trough (12 h for ACL and 24 h for TIO), in addition to domiciliary diurnal spirometry. RESULTS: 13 patients were completed: mean age 69 years, FEV(1) 52 % predicted, FEV(1)/FVC 0.48, and R5 202 % predicted. There were no differences in any visit-based trough IOS or spirometry outcomes comparing TIO versus ACL. Resonant frequency but not total airway resistance at 5 Hz (R5) significantly improved from baseline with both treatments while peripheral airway resistance (R5–R20) significantly improved with ACL. Visit-based FEV(1), and forced and relaxed vital capacity were also significantly improved from baseline with both treatments. There were no significant differences in diurnal FEV(1) and FEV(6) profiles between treatments. 6-min walk distance and post-walk fatigue significantly improved from baseline with ACL, while post-walk dyspnea improved with TIO. SGRQ symptom score significantly improved to a similar degree with both treatments. TDI significantly improved with ACL versus TIO by 1.54 units. CONCLUSION: We observed comparable bronchodilator efficacy at trough with TIO and ACL when used as triple therapy in COPD, while IOS was no more sensitive than spirometry

    Measurement and Interpretation of Fermion-Pair Production at LEP energies above the Z Resonance

    Full text link
    This paper presents DELPHI measurements and interpretations of cross-sections, forward-backward asymmetries, and angular distributions, for the e+e- -> ffbar process for centre-of-mass energies above the Z resonance, from sqrt(s) ~ 130 - 207 GeV at the LEP collider. The measurements are consistent with the predictions of the Standard Model and are used to study a variety of models including the S-Matrix ansatz for e+e- -> ffbar scattering and several models which include physics beyond the Standard Model: the exchange of Z' bosons, contact interactions between fermions, the exchange of gravitons in large extra dimensions and the exchange of sneutrino in R-parity violating supersymmetry.Comment: 79 pages, 16 figures, Accepted by Eur. Phys. J.

    A Determination of the Centre-of-Mass Energy at LEP2 using Radiative 2-fermion Events

    Full text link
    Using e+e- -> mu+mu-(gamma) and e+e- -> qqbar(gamma) events radiative to the Z pole, DELPHI has determined the centre-of-mass energy, sqrt{s}, using energy and momentum constraint methods. The results are expressed as deviations from the nominal LEP centre-of-mass energy, measured using other techniques. The results are found to be compatible with the LEP Energy Working Group estimates for a combination of the 1997 to 2000 data sets.Comment: 20 pages, 6 figures, Accepted by Eur. Phys. J.

    A Measurement of the Tau Hadronic Branching Ratios

    Get PDF
    The exclusive and semi-exclusive branching ratios of the tau lepton hadronic decay modes (h- v_t, h- pi0 v_t, h- pi0 pi0 v_t, h- \geq 2pi0 v_t, h- \geq 3pi0 v_t, 2h- h+ v_t, 2h- h+ pi0 v_t, 2h- h+ \geq 2pi0 v_t, 3h- 2h+ v_t and 3h- 2h+ \geq 1pi0 v_t) were measured with data from the DELPHI detector at LEP.Comment: 53 pages, 18 figures, Accepted by Eur. Phys. J.

    Search for the standard model Higgs boson at LEP

    Get PDF

    Observation of an Excited Bc+ State

    Get PDF
    Using pp collision data corresponding to an integrated luminosity of 8.5 fb-1 recorded by the LHCb experiment at center-of-mass energies of s=7, 8, and 13 TeV, the observation of an excited Bc+ state in the Bc+π+π- invariant-mass spectrum is reported. The observed peak has a mass of 6841.2±0.6(stat)±0.1(syst)±0.8(Bc+) MeV/c2, where the last uncertainty is due to the limited knowledge of the Bc+ mass. It is consistent with expectations of the Bc∗(2S31)+ state reconstructed without the low-energy photon from the Bc∗(1S31)+→Bc+Îł decay following Bc∗(2S31)+→Bc∗(1S31)+π+π-. A second state is seen with a global (local) statistical significance of 2.2σ (3.2σ) and a mass of 6872.1±1.3(stat)±0.1(syst)±0.8(Bc+) MeV/c2, and is consistent with the Bc(2S10)+ state. These mass measurements are the most precise to date

    Search for supersymmetric particles in scenarios with a gravitino LSP and stau NLSP

    Get PDF
    Sleptons, neutralinos and charginos were searched for in the context of scenarios where the lightest supersymmetric particle is the gravitino. It was assumed that the stau is the next-to-lightest supersymmetric particle. Data collected with the DELPHI detector at a centre-of-mass energy near 189 GeV were analysed combining the methods developed in previous searches at lower energies. No evidence for the production of these supersymmetric particles was found. Hence, limits were derived at 95% confidence level.Comment: 31 pages, 14 figure

    Removal of cationic pollutants from water by xanthated corn cob: optimization, kinetics, thermodynamics, and prediction of purification process

    Get PDF
    The removal of Cr(III) ions and methylene blue (MB) from aqueous solutions by xanthated corn cob (xCC) in batch conditions was investigated. The sorption capacity of xCC strongly depended of the pH, and increase when the pH rises. The kinetics was well fitted by pseudo-second order and Chrastil’s model. Sorption of Cr(III) ions and MB on xCC was rapid during the first 20 min of contact time and, thereafter, the biosorption rate decrease gradually until reaching equilibrium. The maximum sorption capacity of 17.13 and 83.89 mg g-1 for Cr(III) ions and MB, respectively was obtained at 40 °C, pH 5 and sorbent dose 4 g dm-3 for removal of Cr(III) ions and 1 g dm-3 for removal of MB. The prediction of purification process was successfully carried out and the verification of theoretically calculated amounts of sorbent was confirmed by using packed-bed column laboratory system with recirculation of the aqueous phase. The wastewater from chrome plating industry was successfully purified, i.e. after 40 min concentration of Cr(III) ions was decreased lower than 0.1 mg dm-3. Also, removal of MB from the river water was successfully carried out and after 40 min removal efficiency was about 94 %
    • 

    corecore