77 research outputs found

    Electronic properties of very thin native SiO2/a-Si:H interfaces and their comparison with those prepared by both dielectric barrier discharge oxidation at atmospheric pressure and by chemical oxidation

    Get PDF
    The contribution deals with electronic properties of thin oxide/amorphous hydrogenated silicon (a-Si:H) measured by capacitance-voltage (C-V) and charge version of deep level transient spectroscopy (Q-DLTS). The interest was focused on the studies of the interface properties of very thin dielectrics formed by dielectric barrier discharge (DBD) or natively on the a-Si:H layer. These properties were compared with those of oxide layers prepared by chemical oxidation in HNO3. The DBD was used for the preparation of a very thin SiO2 layer on a-Si:H for the first time to our knowledge. Preliminary electrical measurements confirmed that a very low interface states density was detected in the case of the native oxide/a-Si:H and DBD oxide/a-Si:H

    Comparison of die geometry for cold drawing of multi-rifled steel tubes

    Get PDF
    Multi-rifled tubes, i.e. tubes with multiple inner grooving are used in heat exchangers and boilers, providing favourable heat transfer conditions due to turbulent flow of cooling medium. Therefore, strict requirements are placed on the geometry of inner rifling. In production of such tubes, cold drawing with free-to-rotate rifled plug is the final drawing operation to achieve required dimensions. A Finite Element Method (FEM) based numerical model of the process was prepared in order to optimize the geometry of the die. The results of numerical simulations for two different die geometries show the difference in material flow and corresponding drawing force. The final dimensions of the tubes after drawing were compared with the customer`s requirements and a good agreement was found

    Final Design of Secondary Refrigeration System and Wind Tunnel

    Get PDF
    The goal of the secondary refrigeration system project was to design and build a secondary refrigeration loop to interface with an existing primary refrigeration loop for the testing and research of microencapsulated phase change material, as well as an educational tool for students interested in refrigeration. The aim of this report is to discuss and explain the final version of the design, the testing methods, results, conclusion, and any future recommendations. The wind tunnel is operational, reaching an average maximum air velocity close to what the group had aimed for. The heaters were able to heat the air to the desired range. Piping and most components and instrumentation have been connected and mounted. LabVIEW has been set up to read the outputs of the instruments. Unfortunately, the steam generator has not been mounted and the system has not been charged due to time constraints. Since much time was spent fixing the primary loop to an operational state, it is recommended that future groups working on the existing refrigeration loops ensure that they are working prior to the start of a new project. Overall, the client who requested this system is satisfied with the outcome, despite not meeting certain design criteria

    Tolerance of Anadenanthera peregrina to Eucalyptus camaldulensis and Eucalyptus grandis essential oil as condition for mixed plantation.

    Get PDF
    With the purpose of selecting the species of woody Caatinga for mixed plantations with Eucalyptus spp., the allelophatic effects of E. camaldulensis and E. grandis essential oil were studied on the growth activities of Anadenanthera peregrina. The plants were closed in glass chambers in the presence of volatile oil of E. camaldulensis or E. grandis at the concentration of 13 nl.cm-3. The number of leaves, height and diameter at soil lever were compared before, immediately after and after 30 days. Chlorophyll a and b, carotenoids and dry mass were evaluated after the treatment application. There was no inhibitory effect of E. camaldulensis and E. grandis oils on A. peregrina. E. camaldulensis, which was more adapted to semi-arid conditions, was planted in mixture stands with two native legume species, inoculated with Rhizobium and arbuscular mycorrhizal fungi. E. camaldulensis did not inhibit native species growth after two years of cultivation

    Systematic review and meta-analysis of the diagnostic accuracy of ultrasonography for deep vein thrombosis

    Get PDF
    Background Ultrasound (US) has largely replaced contrast venography as the definitive diagnostic test for deep vein thrombosis (DVT). We aimed to derive a definitive estimate of the diagnostic accuracy of US for clinically suspected DVT and identify study-level factors that might predict accuracy. Methods We undertook a systematic review, meta-analysis and meta-regression of diagnostic cohort studies that compared US to contrast venography in patients with suspected DVT. We searched Medline, EMBASE, CINAHL, Web of Science, Cochrane Database of Systematic Reviews, Cochrane Controlled Trials Register, Database of Reviews of Effectiveness, the ACP Journal Club, and citation lists (1966 to April 2004). Random effects meta-analysis was used to derive pooled estimates of sensitivity and specificity. Random effects meta-regression was used to identify study-level covariates that predicted diagnostic performance. Results We identified 100 cohorts comparing US to venography in patients with suspected DVT. Overall sensitivity for proximal DVT (95% confidence interval) was 94.2% (93.2 to 95.0), for distal DVT was 63.5% (59.8 to 67.0), and specificity was 93.8% (93.1 to 94.4). Duplex US had pooled sensitivity of 96.5% (95.1 to 97.6) for proximal DVT, 71.2% (64.6 to 77.2) for distal DVT and specificity of 94.0% (92.8 to 95.1). Triplex US had pooled sensitivity of 96.4% (94.4 to 97.1%) for proximal DVT, 75.2% (67.7 to 81.6) for distal DVT and specificity of 94.3% (92.5 to 95.8). Compression US alone had pooled sensitivity of 93.8 % (92.0 to 95.3%) for proximal DVT, 56.8% (49.0 to 66.4) for distal DVT and specificity of 97.8% (97.0 to 98.4). Sensitivity was higher in more recently published studies and in cohorts with higher prevalence of DVT and more proximal DVT, and was lower in cohorts that reported interpretation by a radiologist. Specificity was higher in cohorts that excluded patients with previous DVT. No studies were identified that compared repeat US to venography in all patients. Repeat US appears to have a positive yield of 1.3%, with 89% of these being confirmed by venography. Conclusion Combined colour-doppler US techniques have optimal sensitivity, while compression US has optimal specificity for DVT. However, all estimates are subject to substantial unexplained heterogeneity. The role of repeat scanning is very uncertain and based upon limited data

    Early stroke-related deep venous thrombosis: risk factors and influence on outcome

    Get PDF
    Deep venous thrombosis (DVT) is a serious complication of various medical conditions including acute stroke. Our aim was to identify the occurrence of early stroke-related DVT, risk factors for its development and the influence on outcome. The study involved consecutive patients admitted to our center due to acute ischaemic (n = 278) or haemorrhagic (n = 12) stroke during a 16-month period. We collected data on their pre-stroke health status, neurological deficit on admission and baseline serum CRP and fibrinogen level. Ultrasonographic imaging was performed at the 3rd (IQR: 2–4) and 9th (IQR: 8–9) day after stroke. Patients thrombosis occurring between the first and second examination comprised the newly developed early stroke-related DVT group. We found DVT in 8.0% (24/299) of patients at initial evaluation. Newly developed DVT was present in 3.0% (9/299) of patients, and was predominantly distal (7 of 9 cases). It was associated with elevated serum CRP level (OR 8.75; 95%CI: 1.61–47.6), which was verified in a model adjusted for stroke severity and pre-stroke dependency (3–5 pts. in mRS). In a multivariate model, newly developed DVT significantly increased the risk of 3-month mortality (OR 12.4; 95%CI: 1.72–89.4), without affecting the combined risk of dependency and death (OR 2.57; 95%CI: 0.39–17.0). Early stroke-related DVT is an infrequent complication. However, it may be an independent risk factor for 3-month mortality. Increased serum CRP level combined with normal fibrinogen level seems predictive for development of DVT. It may be reasonable to provide those patients with additional DVT prophylaxis

    Aging-Aware Request Scheduling for Non-Volatile Main Memory

    Full text link
    Modern computing systems are embracing non-volatile memory (NVM) to implement high-capacity and low-cost main memory. Elevated operating voltages of NVM accelerate the aging of CMOS transistors in the peripheral circuitry of each memory bank. Aggressive device scaling increases power density and temperature, which further accelerates aging, challenging the reliable operation of NVM-based main memory. We propose HEBE, an architectural technique to mitigate the circuit aging-related problems of NVM-based main memory. HEBE is built on three contributions. First, we propose a new analytical model that can dynamically track the aging in the peripheral circuitry of each memory bank based on the bank's utilization. Second, we develop an intelligent memory request scheduler that exploits this aging model at run time to de-stress the peripheral circuitry of a memory bank only when its aging exceeds a critical threshold. Third, we introduce an isolation transistor to decouple parts of a peripheral circuit operating at different voltages, allowing the decoupled logic blocks to undergo long-latency de-stress operations independently and off the critical path of memory read and write accesses, improving performance. We evaluate HEBE with workloads from the SPEC CPU2017 Benchmark suite. Our results show that HEBE significantly improves both performance and lifetime of NVM-based main memory.Comment: To appear in ASP-DAC 202

    Safety of intravenous ferric carboxymaltose versus oral iron in patients with nondialysis-dependent CKD: an analysis of the 1-year FIND-CKD trial.

    Get PDF
    Background: The evidence base regarding the safety of intravenous (IV) iron therapy in patients with chronic kidney disease (CKD) is incomplete and largely based on small studies of relatively short duration. Methods: FIND-CKD (ClinicalTrials.gov number NCT00994318) was a 1-year, open-label, multicenter, prospective study of patients with nondialysis-dependent CKD, anemia and iron deficiency randomized (1:1:2) to IV ferric carboxymaltose (FCM), targeting higher (400-600 µg/L) or lower (100-200 µg/L) ferritin, or oral iron. A post hoc analysis of adverse event rates per 100 patient-years was performed to assess the safety of FCM versus oral iron over an extended period. Results: The safety population included 616 patients. The incidence of one or more adverse events was 91.0, 100.0 and 105.0 per 100 patient-years in the high ferritin FCM, low ferritin FCM and oral iron groups, respectively. The incidence of adverse events with a suspected relation to study drug was 15.9, 17.8 and 36.7 per 100 patient-years in the three groups; for serious adverse events, the incidence was 28.2, 27.9 and 24.3 per 100 patient-years. The incidence of cardiac disorders and infections was similar between groups. At least one ferritin level ≥800 µg/L occurred in 26.6% of high ferritin FCM patients, with no associated increase in adverse events. No patient with ferritin ≥800 µg/L discontinued the study drug due to adverse events. Estimated glomerular filtration rate remained the stable in all groups. Conclusions: These results further support the conclusion that correction of iron deficiency anemia with IV FCM is safe in patients with nondialysis-dependent CKD

    Design and baseline characteristics of the finerenone in reducing cardiovascular mortality and morbidity in diabetic kidney disease trial

    Get PDF
    Background: Among people with diabetes, those with kidney disease have exceptionally high rates of cardiovascular (CV) morbidity and mortality and progression of their underlying kidney disease. Finerenone is a novel, nonsteroidal, selective mineralocorticoid receptor antagonist that has shown to reduce albuminuria in type 2 diabetes (T2D) patients with chronic kidney disease (CKD) while revealing only a low risk of hyperkalemia. However, the effect of finerenone on CV and renal outcomes has not yet been investigated in long-term trials. Patients and Methods: The Finerenone in Reducing CV Mortality and Morbidity in Diabetic Kidney Disease (FIGARO-DKD) trial aims to assess the efficacy and safety of finerenone compared to placebo at reducing clinically important CV and renal outcomes in T2D patients with CKD. FIGARO-DKD is a randomized, double-blind, placebo-controlled, parallel-group, event-driven trial running in 47 countries with an expected duration of approximately 6 years. FIGARO-DKD randomized 7,437 patients with an estimated glomerular filtration rate >= 25 mL/min/1.73 m(2) and albuminuria (urinary albumin-to-creatinine ratio >= 30 to <= 5,000 mg/g). The study has at least 90% power to detect a 20% reduction in the risk of the primary outcome (overall two-sided significance level alpha = 0.05), the composite of time to first occurrence of CV death, nonfatal myocardial infarction, nonfatal stroke, or hospitalization for heart failure. Conclusions: FIGARO-DKD will determine whether an optimally treated cohort of T2D patients with CKD at high risk of CV and renal events will experience cardiorenal benefits with the addition of finerenone to their treatment regimen. Trial Registration: EudraCT number: 2015-000950-39; ClinicalTrials.gov identifier: NCT02545049
    corecore