68 research outputs found
Trial participants' self-reported understanding of randomisation phrases in participation information leaflets can be high, but acceptability of some descriptions is low, especially those linked to gambling and luck
Background: Evidence indicates that trial participants often struggle to understand participant information leaflets (PILs) for clinical trials, including the concept of randomisation. We analysed the language used to describe randomisation in PILs and determine the most understandable and acceptable description through public and participant feedback. Methods: We collected 280 PILs/informed consent forms and one video animation from clinical research facilities/clinical trial units in Ireland and the UK. We extracted text on how randomisation was described, plus trial characteristics. We conducted content analysis to group the randomisation phrases inductively. We then excluded phrases that appeared more than once or were very similar to others. The final list of randomisation phrases was then presented to an online panel of participants and the public. Panel members were asked to rate each phrase on a 5-point Likert scale in terms of their understanding of the phrase, confidence in their understanding and acceptability of the phrase. Results: Two hundred and eighty PILs and the transcribed text from one video animation represented 229 ongoing or concluded trials. The pragmatic content analysis generated five inductive categories: (1) explanation of why randomisation is required in trials; (2) synonyms for randomisation; (3) comparative randomisation phrases; (4) elaborative phrases for randomisation (5) and phrases that describe the process of randomisation. We had 48 unique phrases, which were shared with 73 participants and members of the public. Phrases that were well understood were not necessarily acceptable. Participants understood, but disliked, comparative phrases that referenced gambling, e.g. toss of a coin, like a lottery, roll of a die. They also disliked phrases that attributed decision-making to computers or automated systems. Participants liked plain language descriptions of what randomisation is and those that did not use comparative phrases. Conclusions: Potential trial participants are clear on their likes and dislikes when it comes to describing randomisation in PILs. We make five recommendations for practice
Chapter Globally Optimised Energy-Efficient Data Centres
A great deal of energy in Information and Communication Technology (ICT) systems can be wasted by software, regardless of how energy-efficient the underlying hardware is. To avoid such waste, programmers need to understand the energy consumption of programs during the development process rather than waiting to measure energy after deployment. Such understanding is hindered by the large conceptual gap from hardware, where energy is consumed, to high-level languages and programming abstractions. The approaches described in this chapter involve two main topics: energy modelling and energy analysis. The purpose of modelling is to attribute energy values to programming constructs, whether at the level of machine instructions, intermediate code or source code. Energy analysis involves inferring the energy consumption of a program from the program semantics along with an energy model. Finally, the chapter discusses how energy analysis and modelling techniques can be incorporated in software engineering tools, including existing compilers, to assist the energy-aware programmer to optimise the energy consumption of code
Diagnostic accuracy of 18F Prostate Specific Membrane Antigen (PSMA) PET-CT radiotracers in staging and restaging of high-risk prostate cancer patients and patients with biochemical recurrence: protocol for an overview of reviews [version 2; peer review: 2 approved]
Background Correct staging and risk stratification is essential in ensuring prostate cancer patients are offered the most appropriate treatment. Interest has been growing in the use of radiotracers targeting prostate specific membrane antigen (PSMA), including the use of 18F-PSMA PET-CT, as part of the primary staging or restaging of prostate cancer. Preliminary scoping identified a number of relevant systematic reviews and meta-analyses; however, individually, these each appear to look at only part of the picture. An overview of reviews aims to systematically identify, appraise and synthesise multiple systematic reviews, related to a relevant research question or questions. We present a protocol for an overview of reviews, which aims to collate existing evidence syntheses exploring the diagnostic accuracy of 18F-PSMA in staging and restaging of prostate cancer. It also aims to highlight evidence gaps in prostate cancer staging or restaging. Methods This protocol is reported in line with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for systematic review protocols (PRISMA-P). The search strategy will be designed in consultation with a librarian. Searches will be performed in Medline (EBSCO), Embase (Ovid), Google Scholar and the Cochrane Database for Systematic Reviews, supplemented by a targeted grey literature search, forward citation searching and searching reference lists of included reviews. No language or date restrictions will be applied to the eligibility criteria or the search strategy. Title & abstract and full text screening will be performed independently by two reviewers. Data will be extracted by one reviewer and checked in full by a second reviewer. Quality appraisal will be performed using the Risk of Bias in Systematic Reviews (ROBIS) tool independently by two reviewers, and results will be narratively synthesised. Conclusions This overview of reviews may be of interest to healthcare professionals, academics and health policy decision-makers. Registration OSF (September 7, 2023)
Diagnostic accuracy of 18F Prostate Specific Membrane Antigen (PSMA) PET-CT radiotracers in staging and restaging of high-risk prostate cancer patients and patients with biochemical recurrence: protocol for an overview of reviews [version 1; peer review: 2 approved]
Background: Correct staging and risk stratification is essential in ensuring prostate cancer patients are offered the most appropriate treatment. Interest has been growing in the use of radiotracers targeting prostate specific membrane antigen (PSMA), including the use of 18F-PSMA PET-CT, as part of the primary staging or restaging of prostate cancer. Preliminary scoping identified a number of relevant systematic reviews and meta-analyses; however, individually, these each appear to look at only part of the picture. An overview of reviews aims to systematically identify, appraise and synthesise multiple systematic reviews, related to a relevant research question or questions. We present a protocol for an overview of reviews, which aims to collate existing evidence syntheses exploring the diagnostic accuracy of 18F-PSMA in staging and restaging of prostate cancer. It also aims to highlight evidence gaps in prostate cancer staging or restaging. Methods: This protocol is reported in line with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for systematic review protocols (PRISMA-P). The search strategy will be designed in consultation with a librarian. Searches will be performed in Medline (EBSCO), Embase (Ovid), Google Scholar and the Cochrane Database for Systematic Reviews, supplemented by a targeted grey literature search, forward citation searching and searching reference lists of included reviews. No language or date restrictions will be applied to the eligibility criteria or the search strategy. Title & abstract and full text screening will be performed independently by two reviewers. Data will be extracted by one reviewer and checked in full by a second reviewer. Quality appraisal will be performed using the Risk of Bias in Systematic Reviews (ROBIS) tool independently by two reviewers, and results will be narratively synthesised. Conclusions: This overview of reviews may be of interest to healthcare professionals, academics and health policy decision-makers. Registration: OSF (September 7, 2023)
Influence of Finishing Systems on Carcass Characteristics, Composition, and Fatty Acid Profile of Bison Bulls
The objective of this study was to determine the influence of grain- and grass-finishing systems on carcass characteristics of bison bulls and proximate and fatty acid compositions of bison steaks. Bison bulls grazed native pasture until approximately 25 mo of age, then were randomly assigned to grain-finishing (n=98) or grass-finishing (n=98) treatments. Bulls were slaughtered at approximately 30 mo of age. Hot carcass weight (HCW), ribeye area, backfat thickness, kidney fat percentage, marbling score, and instrumental color (L*,a*, and b*) of the ribeye and subcutaneous fat were recorded. Skeletal maturity, lean maturity, and fat color were subjectively scored. Strip loins were collected from a sub-sample of carcasses, fabricated into 2.5-cm steaks, and designated for proximate, cholesterol, or fatty acid analyses. Grain-finished bulls had greater (P<0.0001) HCW, dressing percentage, ribeye area, backfat thickness, kidney fat percentage,and marbling score. The a* and b* values of the ribeye and a* value of subcutaneous fat were greater (P<0.0001), but the L* and b* values of subcutaneous fat were less (P<0.0001) for grain-finished bulls. A greater proportion (P<0.001) of grain-finished carcasses had moderately bright red lean color, whereas a greater proportion (P<0.0001) of grass-finished carcasses had moderately yellow fat color. Steaks from grain-finished bulls had an increased percentage of crude protein (P<0.0001), fat (P<0.0001), and ash (P=0.0006) content but less moisture (P<0.0001). Steaks from grain-finished bulls had more (P<0.001) cholesterol and palmitic, stearic, oleic, linoleic, and arachidonic acids in addition to more total fatty acids (mg/g of wet tissue). However, for total fatty acids, grass-finished steaks had a greater (P<0.0001) percentage of polyunsaturated fatty acids. These data indicate that the finishing system influences the composition of bison bull carcasses as well as the nutrient profile of bison meat
Fusion Learning Colloquium 2022 - Proceedings
This is the proceedings of the 2022 Fusion Learning Colloquium held at Bournemouth University in the UK
Diversity of methicillin-resistant staphylococcus aureus strains isolated from residents of 26 nursing homes in orange county, california
Nursing homes represent a unique and important methicillin-resistant Staphylococcus aureus (MRSA) reservoir. Not only are strains imported from hospitals and the community, strains can be transported back into these settings from nursing homes. Since MRSA bacteria are prevalent in nursing homes and yet relatively poorly studied in this setting, a multicenter, regional assessment of the frequency and diversity of MRSA in the nursing home reservoir was carried out and compared to that of the MRSA from hospitals in the same region. The prospective study collected MRSA from nasal swabbing of residents of 26 nursing homes in Orange County, California, and characterized each isolate by spa typing. A total of 837 MRSA isolates were collected from the nursing homes. Estimates of admission prevalence and point prevalence of MRSA were 16% and 26%, respectively. The spa type genetic diversity was heterogeneous between nursing homes and significantly higher overall (77%) than the diversity in Orange County hospitals (72%). MRSA burden in nursing homes appears largely due to importation from hospitals. As seen in Orange County hospitals, USA300 (sequence type 8 [ST8]/t008), USA100 (ST5/t002), and a USA100 variant (ST5/t242) were the dominant MRSA clones in Orange County nursing homes, representing 83% of all isolates, although the USA100 variant was predominant in nursing homes, whereas USA300 was predominant in hospitals. Control strategies tailored to the complex problem of MRSA transmission and infection in nursing homes are needed in order to minimize the impact of this unique reservoir on the overall regional MRSA burden. Copyright © 2013, American Society for Microbiology. All Rights Reserved
Impact of opioid-free analgesia on pain severity and patient satisfaction after discharge from surgery: multispecialty, prospective cohort study in 25 countries
Background: Balancing opioid stewardship and the need for adequate analgesia following discharge after surgery is challenging. This study aimed to compare the outcomes for patients discharged with opioid versus opioid-free analgesia after common surgical procedures.Methods: This international, multicentre, prospective cohort study collected data from patients undergoing common acute and elective general surgical, urological, gynaecological, and orthopaedic procedures. The primary outcomes were patient-reported time in severe pain measured on a numerical analogue scale from 0 to 100% and patient-reported satisfaction with pain relief during the first week following discharge. Data were collected by in-hospital chart review and patient telephone interview 1 week after discharge.Results: The study recruited 4273 patients from 144 centres in 25 countries; 1311 patients (30.7%) were prescribed opioid analgesia at discharge. Patients reported being in severe pain for 10 (i.q.r. 1-30)% of the first week after discharge and rated satisfaction with analgesia as 90 (i.q.r. 80-100) of 100. After adjustment for confounders, opioid analgesia on discharge was independently associated with increased pain severity (risk ratio 1.52, 95% c.i. 1.31 to 1.76; P < 0.001) and re-presentation to healthcare providers owing to side-effects of medication (OR 2.38, 95% c.i. 1.36 to 4.17; P = 0.004), but not with satisfaction with analgesia (beta coefficient 0.92, 95% c.i. -1.52 to 3.36; P = 0.468) compared with opioid-free analgesia. Although opioid prescribing varied greatly between high-income and low- and middle-income countries, patient-reported outcomes did not.Conclusion: Opioid analgesia prescription on surgical discharge is associated with a higher risk of re-presentation owing to side-effects of medication and increased patient-reported pain, but not with changes in patient-reported satisfaction. Opioid-free discharge analgesia should be adopted routinely
Safety and efficacy of the ChAdOx1 nCoV-19 vaccine (AZD1222) against SARS-CoV-2: an interim analysis of four randomised controlled trials in Brazil, South Africa, and the UK
Background
A safe and efficacious vaccine against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), if deployed with high coverage, could contribute to the control of the COVID-19 pandemic. We evaluated the safety and efficacy of the ChAdOx1 nCoV-19 vaccine in a pooled interim analysis of four trials.
Methods
This analysis includes data from four ongoing blinded, randomised, controlled trials done across the UK, Brazil, and South Africa. Participants aged 18 years and older were randomly assigned (1:1) to ChAdOx1 nCoV-19 vaccine or control (meningococcal group A, C, W, and Y conjugate vaccine or saline). Participants in the ChAdOx1 nCoV-19 group received two doses containing 5 × 1010 viral particles (standard dose; SD/SD cohort); a subset in the UK trial received a half dose as their first dose (low dose) and a standard dose as their second dose (LD/SD cohort). The primary efficacy analysis included symptomatic COVID-19 in seronegative participants with a nucleic acid amplification test-positive swab more than 14 days after a second dose of vaccine. Participants were analysed according to treatment received, with data cutoff on Nov 4, 2020. Vaccine efficacy was calculated as 1 - relative risk derived from a robust Poisson regression model adjusted for age. Studies are registered at ISRCTN89951424 and ClinicalTrials.gov, NCT04324606, NCT04400838, and NCT04444674.
Findings
Between April 23 and Nov 4, 2020, 23 848 participants were enrolled and 11 636 participants (7548 in the UK, 4088 in Brazil) were included in the interim primary efficacy analysis. In participants who received two standard doses, vaccine efficacy was 62·1% (95% CI 41·0–75·7; 27 [0·6%] of 4440 in the ChAdOx1 nCoV-19 group vs71 [1·6%] of 4455 in the control group) and in participants who received a low dose followed by a standard dose, efficacy was 90·0% (67·4–97·0; three [0·2%] of 1367 vs 30 [2·2%] of 1374; pinteraction=0·010). Overall vaccine efficacy across both groups was 70·4% (95·8% CI 54·8–80·6; 30 [0·5%] of 5807 vs 101 [1·7%] of 5829). From 21 days after the first dose, there were ten cases hospitalised for COVID-19, all in the control arm; two were classified as severe COVID-19, including one death. There were 74 341 person-months of safety follow-up (median 3·4 months, IQR 1·3–4·8): 175 severe adverse events occurred in 168 participants, 84 events in the ChAdOx1 nCoV-19 group and 91 in the control group. Three events were classified as possibly related to a vaccine: one in the ChAdOx1 nCoV-19 group, one in the control group, and one in a participant who remains masked to group allocation.
Interpretation
ChAdOx1 nCoV-19 has an acceptable safety profile and has been found to be efficacious against symptomatic COVID-19 in this interim analysis of ongoing clinical trials
- …
