261 research outputs found

    Fall Risk Assessment Tools for Elderly Living in the Community: Can We Do Better?

    Get PDF
    Background Falls are a common, serious threat to the health and self-confidence of the elderly. Assessment of fall risk is an important aspect of effective fall prevention programs. Objectives and methods In order to test whether it is possible to outperform current prognostic tools for falls, we analyzed 1010 variables pertaining to mobility collected from 976 elderly subjects (InCHIANTI study). We trained and validated a data-driven model that issues probabilistic predictions about future falls. We benchmarked the model against other fall risk indicators: history of falls, gait speed, Short Physical Performance Battery (Guralnik et al. 1994), and the literature-based fall risk assessment tool FRAT-up (Cattelani et al. 2015). Parsimony in the number of variables included in a tool is often considered a proxy for ease of administration. We studied how constraints on the number of variables affect predictive accuracy. Results The proposed model and FRAT-up both attained the same discriminative ability; the area under the Receiver Operating Characteristic (ROC) curve (AUC) for multiple falls was 0.71. They outperformed the other risk scores, which reported AUCs for multiple falls between 0.64 and 0.65. Thus, it appears that both data-driven and literature-based approaches are better at estimating fall risk than commonly used fall risk indicators. The accuracy–parsimony analysis revealed that tools with a small number of predictors (~1-5) were suboptimal. Increasing the number of variables improved the predictive accuracy, reaching a plateau at ~20-30, which we can consider as the best trade-off between accuracy and parsimony. Obtaining the values of these ~20-30 variables does not compromise usability, since they are usually available in comprehensive geriatric assessments

    Quality Assessment and Morphological Analysis of Photoplethysmography in Daily Life

    Get PDF
    The photoplethysmographic (PPG) signal has been applied in various research fields, with promising results for its future clinical application. However, there are several sources of variability that, if not adequately controlled, can hamper its application in pervasive monitoring contexts. This study assessed and characterized the impact of several sources of variability, such as physical activity, age, sex, and health state on PPG signal quality and PPG waveform parameters (Rise Time, Pulse Amplitude, Pulse Time, Reflection Index, Delta T, and DiastolicAmplitude). We analyzed 31 24 h recordings by as many participants (19 healthy subjects and 12 oncological patients) with a wristband wearable device, selecting a set of PPG pulses labeled with three different quality levels. We implemented a Multinomial Logistic Regression (MLR) model to evaluate the impact of the aforementioned factors on PPG signal quality. We then extracted six parameters only on higher-quality PPG pulses and evaluated the influence of physical activity, age, sex, and health state on these parameters with Generalized Linear Mixed Effects Models (GLMM). We found that physical activity has a detrimental effect on PPG signal quality quality (94% of pulses with good quality when the subject is at rest vs. 9% during intense activity), and that health state affects the percentage of available PPG pulses of the best quality (at rest, 44% for healthy subjects vs. 13% for oncological patients). Most of the extracted parameters are influenced by physical activity and health state, while age significantly impacts two parameters related to arterial stiffness. These results can help expand the awareness that accurate, reliable information extracted from PPG signals can be reached by tackling and modeling different sources of inaccuracy

    Radiolarian biostratigraphic evidence for a Late Jurassic age of the El Tambor Group ophiolites (Guatemala)

    Get PDF
    We present a radiolarian biostratigraphic study of the metacherts of the El Tambor Group ophiolites (South Motagua Unit), Guatemala. The ophiolite sequence comprises MOR pillow metabasalts, massive metabasalts, metacherts and micaschists. The age of the studied metacherts is referable to the Late Jurassic (Oxfordian - Kimmeridgian). The radiolarian assemblage described in this paper is the first Jurassic finding in the ophiolitic MOR succession of the Motagua zone and represents a valuable tool to constrain the geodynamic evolution of the Caribbean area. A review of the ages of Jurassic rocks associated with the ophiolites from the Caribbean area is also reported

    Total cross section measurements for positron scattering from acetone

    Get PDF
    We report results from total cross section measurements for positron-acetone scattering. The energy range of these experiments was 0.2-23 eV, while the energy resolution of our positron beam was ~260 meV. The present data clearly highlight the important role played by the strong permanent dipole moment and significant dipole polarisability of the acetone molecule on the low-energy scattering dynamics of this system. For positron energies above about 6 eV the present data is found to be in quite good agreement with the only other total cross section results available in the literature from the Yamaguchi group, however, at lower energies the level of agreement is rather poor. To the best of our knowledge, no theoretical calculations are currently available for positron-acetone scattering

    Total cross sections for positron scattering from H2 at low energies

    Get PDF
    This paper revisits positron scattering from molecular hydrogen, in an attempt to provide accurate total cross-section data against which theoretical calculations might be benchmarked. The present data were measured over the energy range 0.1–50 eV and, where possible, are compared to results from previous experiments and calculations. Agreement with the earlier data was typically very good at energies above 10 eV but becomes progressively more marginal as we go to lower energies. None of the current theories quantitatively reproduce our measurements over the entire energy range, although at a qualitative level the main features driving the scattering dynamics are apparent

    Physical Activity Classification for Elderly People in Free-Living Conditions

    Get PDF
    Physical activity is strongly linked with mental and physical health in the elderly population and accurate monitoring of activities of daily living (ADLs) can help improve quality of life and well-being. This study presents and validates an inertial sensors-based physical activity classification system developed with older adults as the target population. The dataset was collected in free-living conditions without placing constraints on the way and order of performing ADLs. Four sensor locations (chest, lower back, wrist, and thigh) were explored to obtain the optimal number and combination of sensors by finding the best tradeoff between the system's performance and wearability. Several feature selection techniques were implemented on the feature set obtained from acceleration and angular velocity signals to classify four major ADLs (sitting, standing, walking, and lying). A support vector machine was used for the classification of the ADLs. The findings show the potential of different solutions (single sensor or multisensor) to correctly classify the ADLs of older people in free-living conditions. Considering a minimal set-up of a single sensor, the sensor worn at the L5 achieved the best performance. A two-sensor solution (L5 + thigh) achieved a better performance with respect to a single-sensor solution. By contrast, considering more than two sensors did not provide further improvements. Finally, we evaluated the computational cost of different solutions and it was shown that a feature selection step can reduce the computational cost of the system and increase the system performance in most cases. This can be helpful for real-time applications.<br/

    Performance Evaluation of State of the Art Systems for Physical Activity Classification of Older Subjects Using Inertial Sensors in a Real Life Scenario: A Benchmark Study

    Get PDF
    The popularity of using wearable inertial sensors for physical activity classification has dramatically increased in the last decade due to their versatility, low form factor, and low power requirements. Consequently, various systems have been developed to automatically classify daily life activities. However, the scope and implementation of such systems is limited to laboratory-based investigations. Furthermore, these systems are not directly comparable, due to the large diversity in their design (e.g., number of sensors, placement of sensors, data collection environments, data processing techniques, features set, classifiers, cross-validation methods). Hence, the aim of this study is to propose a fair and unbiased benchmark for the field-based validation of three existing systems, highlighting the gap between laboratory and real-life conditions. For this purpose, three representative state-of-the-art systems are chosen and implemented to classify the physical activities of twenty older subjects (76.4 \ub1 5.6 years). The performance in classifying four basic activities of daily life (sitting, standing, walking, and lying) is analyzed in controlled and free living conditions. To observe the performance of laboratory-based systems in field-based conditions, we trained the activity classification systems using data recorded in a laboratory environment and tested them in real-life conditions in the field. The findings show that the performance of all systems trained with data in the laboratory setting highly deteriorates when tested in real-life conditions, thus highlighting the need to train and test the classification systems in the real-life setting. Moreover, we tested the sensitivity of chosen systems to window size (from 1 s to 10 s) suggesting that overall accuracy decreases with increasing window size. Finally, to evaluate the impact of the number of sensors on the performance, chosen systems are modified considering only the sensing unit worn at the lower back. The results, similarly to the multi-sensor setup, indicate substantial degradation of the performance when laboratory-trained systems are tested in the real-life setting. This degradation is higher than in the multi-sensor setup. Still, the performance provided by the single-sensor approach, when trained and tested with real data, can be acceptable (with an accuracy above 80%)

    Recurrent Neural Networks for Daily Estimation of COVID-19 Prognosis with Uncertainty Handling

    Get PDF
    Most ML-based applications for COVID-19 assess the general conditions of a patient trained and tested on cohorts of patients collected over a short period of time and are capable of providing an alarm a few days in advance, helping clinicians in emergency situations, monitor hospitalised patients and identify potentially critical situations at an early stage. However, the pandemic continues to evolve due to new variants, treatments, and vaccines; considering datasets over short periods could not capture this aspect. In addition, these applications often avoid dealing with the uncertainty associated with the prediction provided by machine learning models, potentially causing costly mistakes. In this work, we present a system based on Recurrent Neural Networks (RNN) for the daily estimate of the prognosis of COVID-19 patients that is built and tested using data collected over a long period of time. Our system achieves high predictive performance and uses an algorithm to effectively determine and discard those patients for whom RNN cannot predict the prognosis with sufficient confidence

    Positron scattering from chiral enantiomers

    Get PDF
    We report on total cross section measurements for positron scattering from the chiral enantiomers (+)-methyl (R)-2-chloropropionate and (–)-methyl (S)-2-chloropropionate. The energy range of the present study was 0.1–50 eV, while the energy resolution of our incident positron beam was ∼0.25 eV (FWHM). As positrons emanating from β decay in radioactive nuclei have a high degree of spin polarization, which persists after moderation, we were particularly interested in probing whether the positron helicity differentiates between the measured total cross sections of the two enantiomers. No major differences were, however, observed. Finally, quantum chemical calculations, using the density functional theory based B3LYP-DGTZVP model within the gaussian 09 package, were performed as a part of this work in order to assist us in interpreting some aspects of our data
    • …
    corecore