9 research outputs found

    Clinical decision support of therapeutic drug monitoring of phenytoin: measured versus adjusted phenytoin plasma concentrations

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Therapeutic drug monitoring of phenytoin by measurement of plasma concentrations is often employed to optimize clinical efficacy while avoiding adverse effects. This is most commonly accomplished by measurement of total phenytoin plasma concentrations. However, total phenytoin levels can be misleading in patients with factors such as low plasma albumin that alter the free (unbound) concentrations of phenytoin. Direct measurement of free phenytoin concentrations in plasma is more costly and time-consuming than determination of total phenytoin concentrations. An alternative to direct measurement of free phenytoin concentrations is use of the Sheiner-Tozer equation to calculate an adjusted phenytoin that corrects for the plasma albumin concentration. Innovative medical informatics tools to identify patients who would benefit from adjusted phenytoin calculations or from laboratory measurement of free phenytoin are needed to improve safety and efficacy of phenytoin pharmacotherapy. The electronic medical record for an academic medical center was searched for the time period from August 1, 1996 to November 30, 2010 for patients who had total phenytoin and free phenytoin determined on the same blood draw, and also a plasma albumin measurement within 7 days of the phenytoin measurements. The measured free phenytoin plasma concentration was used as the gold standard.</p> <p>Results</p> <p>In this study, the standard Sheiner-Tozer formula for calculating an estimated (adjusted) phenytoin level more frequently underestimates than overestimates the measured free phenytoin relative to the respective therapeutic ranges. Adjusted phenytoin concentrations provided superior classification of patients than total phenytoin measurements, particularly at low albumin concentrations. Albumin plasma concentrations up to 7 days prior to total phenytoin measurements can be used for adjusted phenytoin concentrations.</p> <p>Conclusions</p> <p>The results suggest that a measured free phenytoin should be obtained where possible to guide phenytoin dosing. If this is not feasible, then an adjusted phenytoin can supplement a total phenytoin concentration, particularly for patients with low plasma albumin.</p

    Negative CPOE Attitudes Correlate with Diminished Power in the Workplace

    Get PDF
    Power changes have been identified as a frequent and unintended consequence of the implementation of computerized physician order entry (CPOE). However, no previous study has described the degree or direction of power change, or even confirmed that such a relationship exists. Using a validated, standardized instrument for measuring personal power we collected data from 276 healthcare workers in two different hospitals before and after implementation of CPOE. We identified a significant correlation between power perceptions and attitudes toward CPOE. Examining the direction of change by healthcare position, we found that the power perception values decreased for all positions and that attitudes toward CPOE varied based on use of the system. Understanding the relationship between power and CPOE is the first step in enabling systems developers to change the direction of power changes from negative to positive

    Development of an instrument for measuring clinicians' power perceptions in the workplace

    Get PDF
    We report on the development of an instrument to measure clinicians' perceptions of their personal power in the workplace in relation to resistance to computerized physician order entry (CPOE). The instrument is based on French and Raven's six bases of social power and uses a semantic differential methodology. A measurement study was conducted to determine the reliability and validity of the survey. The survey was administered online and distributed via a URL by email to 19 physicians, nurses, and health unit coordinators from a university hospital. Acceptable reliability was achieved by removing or moving some semantic differential word pairs used to represent the six power bases (alpha range from 0.76 to 0.89). The Semantic Differential Power Perception (SDPP) survey validity was tested against an already validated instrument and found to be acceptable (correlation range from 0.51 to 0.81). The SDPP survey instrument was determined to be both reliable and valid. © 2008 Elsevier Inc. All rights reserved

    Proceedings of the 4th World Conference on Research Integrity

    Get PDF
    CITATION: O’Brien, S. P., et al. 2016. Proceedings of the 4th World Conference on Research Integrity. Research Integrity and Peer Review, 1:9, doi:10.1186/s41073-016-0012-9.The original publication is available at https://researchintegrityjournal.biomedcentral.comThese Proceedings contain the abstracts of the presentations given at the 4th World Conference in concurrent sessions, partner symposia, and poster sessions. Also included are summaries of the discussions in three focus tracks, which allowed delegates to consider and work on questions about the roles of funders, institutions, and countries in improving research systems and strengthening research integrity. Videos of the plenary presentations are available at the conference website (www.wcri2015.org).https://researchintegrityjournal.biomedcentral.com/articles/10.1186/s41073-016-0012-
    corecore