44 research outputs found
Simulations of neutron background in a time projection chamber relevant to dark matter searches
Presented here are results of simulations of neutron background performed for
a time projection chamber acting as a particle dark matter detector in an
underground laboratory. The investigated background includes neutrons from rock
and detector components, generated via spontaneous fission and (alpha, n)
reactions, as well as those due to cosmic-ray muons. Neutrons were propagated
to the sensitive volume of the detector and the nuclear recoil spectra were
calculated. Methods of neutron background suppression were also examined and
limitations to the sensitivity of a gaseous dark matter detector are discussed.
Results indicate that neutrons should not limit sensitivity to WIMP-nucleon
interactions down to a level of (1 - 3) x 10^{-8} pb in a 10 kg detector.Comment: 27 pages (total, including 3 tables and 11 figures). Accepted for
publication in Nuclear Instruments and Methods in Physics Research - Section
Neutron background in large-scale xenon detectors for dark matter searches
Simulations of the neutron background for future large-scale particle dark
matter detectors are presented. Neutrons were generated in rock and detector
elements via spontaneous fission and (alpha,n) reactions, and by cosmic-ray
muons. The simulation techniques and results are discussed in the context of
the expected sensitivity of a generic liquid xenon dark matter detector.
Methods of neutron background suppression are investigated. A sensitivity of
pb to WIMP-nucleon interactions can be achieved by a
tonne-scale detector.Comment: 35 pages, 13 figures, 2 tables, accepted for publication in
Astroparticle Physic
The ZEPLIN II dark matter detector: data acquisition system and data reduction
ZEPLIN-II is a two-phase (liquid/gas) xenon dark matter detector searching
for WIMP-nucleon interactions. In this paper we describe the data acquisition
system used to record the data from ZEPLIN-II and the reduction procedures
which parameterise the data for subsequent analysis.Comment: 11 pages, 10 figure
The ZEPLIN II dark matter detector: data acquisition system and data reduction
ZEPLIN-II is a two-phase (liquid/gas) xenon dark matter detector searching
for WIMP-nucleon interactions. In this paper we describe the data acquisition
system used to record the data from ZEPLIN-II and the reduction procedures
which parameterise the data for subsequent analysis.Comment: 11 pages, 10 figure
The ZEPLIN-III dark matter detector: performance study using an end-to-end simulation tool
We present results from a GEANT4-based Monte Carlo tool for end-to-end
simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase
detector which measures both the scintillation light and the ionisation charge
generated in liquid xenon by interacting particles and radiation. The software
models the instrument response to radioactive backgrounds and calibration
sources, including the generation, ray-tracing and detection of the primary and
secondary scintillations in liquid and gaseous xenon, and subsequent processing
by data acquisition electronics. A flexible user interface allows easy
modification of detector parameters at run time. Realistic datasets can be
produced to help with data analysis, an example of which is the position
reconstruction algorithm developed from simulated data. We present a range of
simulation results confirming the original design sensitivity of a few times
pb to the WIMP-nucleon cross-section.Comment: Submitted to Astroparticle Physic
Genome-wide association study of classical Hodgkin lymphoma identifies key regulators of disease susceptibility
Several susceptibility loci for classical Hodgkin lymphoma (cHL) have been reported, however much of the heritable risk is unknown. Here, we perform a meta-analysis of two existing genome-wide association studies (GWAS), a new GWAS, and replication totalling 5,314 cases and 16,749 controls. We identify risk loci for all cHL at 6q22.33 (rs9482849, P=1.52 × 10-8) and for nodular sclerosis HL (NSHL) at 3q28 (rs4459895, P=9.43 × 10-17), 6q23.3 (rs6928977, P=4.62 × 10-55 11), 10p14 (rs3781093, P=9.49 × 10-13), 13q34 (rs112998813, P=4.58 × 10-8) and 16p13.13 (rs34972832, P=2.12 × 10-8). Additionally, independent loci within the HLA region are observed for NSHL (rs9269081, HLA-DPB1*03:01, Val86 in HLA-DRB1) and mixed cellularity HL (rs1633096, rs13196329, Val86 in HLA-DRB1). The new and established risk loci localise to areas of active
chromatin and show an over-representation of transcription factor binding for determinants of B-cell development and immune response.In the United Kingdom, Bloodwise (LLR; 10021) provided principal funding for the study. Support from Cancer Research UK (C1298/A8362 supported by the Bobby Moore Fund) and the Lymphoma Research Trust is also acknowledged. A.S. is supported by a clinical fellowship from Cancer Research UK. For the UK-GWAS, sample and data acquisition were supported by Breast Cancer Now, the European Union and the Lymphoma Research Trust. The UK-GWAS made use of control genotyping data generated by the WTCCC. For further information, please visit the publishr's website
Reducing the environmental impact of surgery on a global scale: systematic review and co-prioritization with healthcare workers in 132 countries
Background
Healthcare cannot achieve net-zero carbon without addressing operating theatres. The aim of this study was to prioritize feasible interventions to reduce the environmental impact of operating theatres.
Methods
This study adopted a four-phase Delphi consensus co-prioritization methodology. In phase 1, a systematic review of published interventions and global consultation of perioperative healthcare professionals were used to longlist interventions. In phase 2, iterative thematic analysis consolidated comparable interventions into a shortlist. In phase 3, the shortlist was co-prioritized based on patient and clinician views on acceptability, feasibility, and safety. In phase 4, ranked lists of interventions were presented by their relevance to high-income countries and low–middle-income countries.
Results
In phase 1, 43 interventions were identified, which had low uptake in practice according to 3042 professionals globally. In phase 2, a shortlist of 15 intervention domains was generated. In phase 3, interventions were deemed acceptable for more than 90 per cent of patients except for reducing general anaesthesia (84 per cent) and re-sterilization of ‘single-use’ consumables (86 per cent). In phase 4, the top three shortlisted interventions for high-income countries were: introducing recycling; reducing use of anaesthetic gases; and appropriate clinical waste processing. In phase 4, the top three shortlisted interventions for low–middle-income countries were: introducing reusable surgical devices; reducing use of consumables; and reducing the use of general anaesthesia.
Conclusion
This is a step toward environmentally sustainable operating environments with actionable interventions applicable to both high– and low–middle–income countries
SCUBA: a common-user submillimetre camera operating on the James Clerk Maxwell Telescope
The definitive version is available at www.blackwell-synergy.com '.--Copyright Blackwell Publishing DOI : 10.1046/j.1365-8711.1999.02111.xSCUBA, the Submillimetre Common-User Bolometer Array, built by the Royal Observatory Edinburgh for the James Clerk Maxwell Telescope, is the most versatile and powerful of a new generation of submillimetre cameras. It combines a sensitive dual-waveband imaging array with a three-band photometer, and is sky-background limited by the emission from the Mauna Kea atmosphere at all observing wavelengths from 350μm to 2mm. The increased sensitivity and array size mean that SCUBA maps close to 10,000 times faster than its single-pixel predecessor (UKT14). SCUBA is a facility instrument, open to the world community of users, and is provided with a high level of user support. We give an overview of the instrument, describe the observing modes and user interface, performance figures on the telescope, and present a sample of the exciting new results that have revolutionised submillimetre astronomy.Peer reviewe